Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Maytag LDE9904ACL washer/dryer

Maytag LDE9904ACL washer/dryer Parts

Here are the diagrams and repair parts for Maytag LDE9904ACL washer/dryer, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for LDE9904ACL Washer/Dryer

  • Washer for Maytag LDE9904ACL - Part WPY311270

    Terminal Washer

    Part #311270

    Replaced by #WPY311270

    Info Icon
    Manufacturer substitution
    This part replaces 311270. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $25.57
    Minus Item
    Qty
    Plus Item
  • Dryer Door Switch for Maytag LDE9904ACL - Part W10169313

    Door Switch

    Part #33001508

    Replaced by #W10169313

    Info Icon
    Manufacturer substitution
    This part replaces 33001508. Substitute parts can look different from the original.
    In Stock
    $21.92
    21% OFF Phone Price : $27.92Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer High-limit Thermostat for Maytag LDE9904ACL - Part WP303395

    Gas valve (ldg9904aae) (ldg9904aal) (ldg9904aam) diagram

    Dryer High-limit Thermostat

    Part #303395

    Replaced by #WP303395

    Info Icon
    Manufacturer substitution
    This part replaces 303395. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $33.62
    15% OFF Phone Price : $39.62Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Blower Wheel Clamp for Maytag LDE9904ACL - Part WP312967

    Blower Wheel Clamp

    Part #312967

    Replaced by #WP312967

    Info Icon
    Manufacturer substitution
    This part replaces 312967. Substitute parts can look different from the original.
    In Stock
    $9.31
    10% OFF Phone Price : $10.31Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Idler Arm Sleeve for Maytag LDE9904ACL - Part WP315772

    Sleeve Idler

    Part #312894

    Replaced by #WP315772

    Info Icon
    Manufacturer substitution
    This part replaces 312894. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $9.31
    10% OFF Phone Price : $10.31Info Icon
    Minus Item
    Qty
    Plus Item
  • Refrigerator Screw for Maytag LDE9904ACL - Part WP489128

    Screw, Groun

    Part #210186

    Replaced by #WP489128

    Info Icon
    Manufacturer substitution
    This part replaces 210186. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $9.45
    10% OFF Phone Price : $10.45Info Icon
    Minus Item
    Qty
    Plus Item
  • Nut for Maytag LDE9904ACL - Part WP488826

    Clip, Wire H

    Part #310376

    Replaced by #WP488826

    Info Icon
    Manufacturer substitution
    This part replaces 310376. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $3.06
    Minus Item
    Qty
    Plus Item
  • Dryer Natural Gas Conversion Kit for Maytag LDE9904ACL - Part WP33002924

    Gas valve (ldg9904aae) (ldg9904aal) (ldg9904aam) diagram

    Conversion Kit

    Part #306204

    Replaced by #WP33002924

    Info Icon
    Manufacturer substitution
    This part replaces 306204. Substitute parts can look different from the original.
    In Stock
    $64.86
    8% OFF Phone Price : $70.86Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Screw for Maytag LDE9904ACL - Part WPW10116751

    Screw

    Part #312961

    Replaced by #WPW10116751

    Info Icon
    Manufacturer substitution
    This part replaces 312961. Substitute parts can look different from the original.
    In Stock
    $28.13
    Minus Item
    Qty
    Plus Item
  • Dryer Lp Conversion Kit for Maytag LDE9904ACL - Part MAL9000AXX

    Gas valve (ldg9904aae) (ldg9904aal) (ldg9904aam) diagram

    Conversion Kit

    Part #306195

    Replaced by #MAL9000AXX

    Info Icon
    Manufacturer substitution
    This part replaces 306195. Substitute parts can look different from the original.
    In Stock
    $47.44
    11% OFF Phone Price : $53.44Info Icon
    Minus Item
    Qty
    Plus Item

Maytag Washer/Dryer LDE9904ACL FAQs

On a Maytag LDE9904ACL dryer, the model number is typically on the cabinet frame in the door opening, or on the back panel near where the vent connects. We use that exact model number to match the correct Maytag dryer parts and diagrams for your unit.

Most common places to check
  • Open the dryer door and look around the door opening (cabinet frame) for a model and serial tag
  • Check the inside of the front panel near the lint screen housing (some versions place the tag nearby)
  • Look on the back of the dryer cabinet, often near the exhaust vent outlet
  • If your dryer is stacked or tight to a wall, pull it forward a few inches to see the rear label safely
Quick tips to find it faster
  • Use a flashlight and look for a silver or white sticker or metal tag
  • Wipe dust off the label gently so the characters are readable
  • Write down the full model number exactly as shown (including any letters)
What the label usually looks like
What you’ll see Why it matters
Model number (example: LDE9904ACL) Ensures parts fit your exact dryer configuration
Serial number Helps identify production run details for some parts
Electrical and gas info Useful when troubleshooting heat or power issues
Why it matters

Maytag dryers can have similar-looking cabinets across multiple model series; using the exact LDE9904ACL model number prevents ordering the wrong items such as a gas igniter 4391996 or dryer thermal fuse, 243-degree f WP307473.

Last updated: February 2026

Yes, many Maytag and Whirlpool dryer parts can interchange, but we always match parts by the exact model number and the original part ID. For your Maytag dryer model LDE9904ACL, confirm fit by using the parts list for that model before ordering.

How to tell if a part will interchange

We treat “interchangeable” as “same fit and function on the same model series.” Use these checks:

  • Match your dryer’s full model number: LDE9904ACL
  • Compare the part ID and description, not just the brand name
  • Confirm the part’s location and function (heat system, drum support, drive system)
  • Watch for gas vs. electric differences (they use different heating components)
  • Replace paired wear parts together when recommended (for example, drum support items)
Common examples on this LDE9904ACL parts list

These parts are listed for LDE9904ACL and are safe starting points when you are comparing Maytag vs. Whirlpool-branded replacements:

Quick compatibility guide
What you are replacing Interchange is often possible when… What can block interchange
Thermal fuse, sensor, igniter Part ID matches and mounting style matches Different temperature rating or connector style
Gas valve coils Coil kit matches the valve design used on the model Different valve body or coil bracket
Drum support parts Same drum design and support layout Different drum size, bearing style, or seal profile
Why it matters

A dryer can look identical across brands, but small differences (connector type, temperature rating, bracket shape) can cause a no-heat condition, poor drying, noise, or premature part failure. Matching to LDE9904ACL prevents ordering the wrong component.

Last updated: February 2026

To clear an error code on your Maytag dryer model LDE9904ACL, we reset power to the control by unplugging the dryer (or switching the breaker off) for a few minutes, then restoring power. If the code returns, troubleshoot the underlying heating, airflow, or wiring issue.

Quick reset steps (most Maytag dryers)
  • Turn the dryer OFF.
  • Unplug the power cord (or switch the dryer breaker OFF).
  • Wait 1 to 5 minutes.
  • Restore power and start a cycle.
  • If the code reappears, stop the cycle and move to the checks below.
If the code comes back: what to check first

Many recurring dryer codes are triggered by overheating, no-heat, or electrical sensing problems.

  • Airflow restriction: clean the lint screen; check the vent hose for kinks or crushing; confirm strong airflow outside.
  • Overheat protection: a blown thermal fuse often points to poor venting; check the dryer thermal fuse, 243-degree f WP307473.
  • Heating system (gas models): if the dryer tumbles but won’t heat, inspect the igniter and flame sensing circuit; common suspects include the gas igniter 4391996 and gas sensor WP338906.
  • Gas valve coils: intermittent heat (heats once, then stops) commonly tracks back to weak coils; check the holding coil 279834.
  • Wiring connections: look for loose terminals or damaged wires at the heater, sensor, and control.
Common symptoms and likely direction
What you notice What it usually points to Good next step
Dryer runs, no heat Ignition/sensing or gas valve issue Check igniter, sensor, coils
Heat starts then quits Weak gas valve coils Test/replace coils
Dryer stops, code returns quickly Overheat/airflow problem Clear venting; test thermal fuse
Burning smell or very hot cabinet Severe airflow restriction Stop using; clean venting fully
Why it matters

Clearing the code only resets the control. If the dryer is overheating or failing to ignite, the code will return until airflow, heating parts, or wiring are corrected.

Last updated: February 2026

Most Maytag dryers use a 93 1/2-inch drum drive belt, and that is the common replacement size you will see for many Maytag-built 29-inch dryers. For your Maytag model LDE9904ACL, confirm the exact belt by matching the belt routing and drum size, then order the correct belt from the parts list for this model on Sears PartsDirect.

Quick ways to confirm the correct belt
  • Check the model tag and use LDE9904ACL when selecting parts.
  • Compare your old belt length and rib style (most are ribbed on one side).
  • Inspect belt routing around the motor pulley and idler pulley.
  • If the belt snapped, look for glazing or cracking that indicates age and heat.
  • If the drum does not turn but the motor runs, the belt is the first item to verify.
What symptoms point to a worn or broken belt?
Symptom What it usually means What to check next
Motor runs, drum does not turn Belt broken or off the drum Belt condition and routing; idler pulley
Squealing or chirping Belt slipping or idler issue Idler pulley and drum support points
Thumping Belt seam or drum support wear Drum rollers/bearing surfaces and felt seal
Burning rubber smell Belt slipping from drag Drum felt seal and drum bearing surfaces
Related parts that often matter during a belt repair

A belt failure is often caused by drag or a tensioning problem. While you have the cabinet open, we recommend checking these common wear items:

Why it matters

Using the correct belt size and routing keeps proper tension on the drum, prevents slipping, and protects the motor and idler system from overload. A slightly wrong belt length can cause noise, poor tumbling, or repeated belt breakage.

Last updated: February 2026

The L2 line voltage error on your Maytag dryer model LDE9904ACL means the dryer is not sensing proper power on the L2 side of the supply, so the heater cannot turn on. The drum can still tumble, but you will get little or no heat until the power issue is corrected.

What you will notice
  • Dryer runs but clothes stay cool or take much longer to dry
  • No heat on heated cycles, but air flow may feel normal
  • Error may clear and return depending on the power interruption
  • Problem often shows up after a breaker trip or power outage
What to check first (safe, no tools)
  1. Reset the power: Turn the dryer off, then reset the dryer breaker fully OFF then back ON.
  2. Check for a tripped breaker: Many dryers use a 2-pole breaker; one side can trip and the motor still runs.
  3. Confirm the outlet is a dryer outlet: Electric dryers need a 240V supply (gas dryers typically use 120V).
  4. Try a timed dry heat cycle: If it tumbles but never heats, treat it as an L2 supply problem first.
If power is correct but there is still no heat

Once you have confirmed proper supply voltage, a no-heat condition can also be caused by a failed safety device or heater circuit component.

Common parts to inspect or test include:

Quick comparison: power problem vs. dryer part problem
Symptom More likely cause What to do next
Tumbles, no heat, error appears right after outage L2 supply issue Reset breaker; verify outlet power
Tumbles, no heat, strong airflow, no recent outage Thermal fuse or cut-off opened Test fuse/cut-off for continuity
No tumble and no heat Power supply or door switch issue Check breaker and basic operation
Why it matters

The L2 error is designed to prevent the dryer from trying to heat with incorrect voltage. Fixing the power supply issue first avoids unnecessary part replacement and helps protect the heater or gas ignition system.

Last updated: February 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Air Compressor
Bottom-Mount Refrigerator
Dishwasher
Front-Engine Lawn Tractor
Laundry Center
Parts
Refrigerator
Room Air Conditioner
Vacuum Cleaner
Washer