Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

All Power APG3014 2000-watt generator Parts

Here are the diagrams and repair parts for All Power APG3014 2000-watt generator, as well as links to manuals and error code tables, if available.

All Power APG3014 2000-watt generator
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for APG3014 2000-Watt Generator

  • Insulation Frame for All Power APG3014 - Part APG3014-G-08-JD

    Throttle diagram

    Insulation Frame

    Part #APG3014-G-08-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Spring for All Power APG3014 - Part APG3014-G-10-JD

    Throttle diagram

    Spring

    Part #APG3014-G-10-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Pin B for All Power APG3014 - Part APG3014-D-03-JD

    Camshaft diagram

    Pin B

    Part #APG3014-D-03-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Recoil Start Rope for All Power APG3014 - Part APG3014-I-05-JD

    Starter diagram

    Recoil Start Rope

    Part #APG3014-I-05-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Brush for All Power APG3014 - Part APG3014-J-08-JD

    Generator diagram

    Brush

    Part #APG3014-J-08-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Recoil Start Case for All Power APG3014 - Part APG3014-I-03-JD

    Starter diagram

    Recoil Start Case

    Part #APG3014-I-03-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Drum Sheave for All Power APG3014 - Part APG3014-I-06-JD

    Starter diagram

    Drum Sheave

    Part #APG3014-I-06-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Platen for All Power APG3014 - Part APG3014-G-03-JD

    Throttle diagram

    Platen

    Part #APG3014-G-03-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt for All Power APG3014 - Part APG3014-I-16-JD

    Starter diagram

    Bolt

    Part #APG3014-I-16-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Starter Pulley for All Power APG3014 - Part APG3014-I-14-JD

    Starter diagram

    Starter Pulley

    Part #APG3014-I-14-JD

    The manufacturer no longer makes this part, and there's no substitute part

All Power 2000-Watt Generator APG3014 FAQs

A 2000-watt generator like the All Power APG3014 can run some 30-amp RV loads, but it typically will not start and run an RV air conditioner reliably because AC compressors have high startup (surge) watts. It works best for lighter essentials when you manage what’s on at the same time.

What it can usually power (and what it usually cannot)

A 30-amp RV service is up to about 3,600 watts (30A × 120V). Your generator’s 2,000 watts is well below that, so you have to “budget” power.

  • Usually OK: LED lights, phone/laptop charging, TV, small fans
  • Often OK (depends on model): RV refrigerator on electric (many owners use propane instead), small microwave briefly
  • Usually not OK: 13.5K to 15K BTU RV air conditioner (startup surge is the problem)
  • Not OK together: microwave + coffee maker + space heater (any two can overload a 2,000W unit)

Quick wattage budgeting (example)

Use this as a practical way to decide what can run at the same time.

RV item Typical running watts Notes
Battery converter/charger 200 to 600 Higher when batteries are low
RV refrigerator (electric mode) 300 to 800 Many switch to propane to save watts
Microwave 900 to 1,500 Short bursts; varies widely
Rooftop AC 1,200 to 1,800 running Startup surge can be much higher

Tips to make a 2,000W generator work better for an RV

  • Start with everything unplugged, then connect loads one at a time after the generator is running (this matches the safe-start guidance in the owner's manual).
  • Turn off the converter/charger temporarily if you need to run a microwave.
  • Use propane for the fridge and water heater when possible to reduce electrical demand.
  • Avoid resistive heaters (space heater, toaster, hair dryer) on a small generator.
  • Use a watt meter to see real-time draw and prevent overload trips.

Why it matters

Overloading a small generator causes voltage drop, breaker trips, and hard starts on motors (like an AC compressor). Managing loads protects your RV appliances and helps the APG3014 run more steadily.

Last updated: February 2026

A 10,000-watt generator can run many essential household loads at the same time, but the generator on this page (All Power APG3014) is a 2000-watt class unit, so it is sized for a few small loads, not whole-home circuits. For safe operation details, follow the APG3014 owner's manual.

What a 10,000-watt generator can typically run

With proper connection (transfer switch or interlock) and load management, 10,000 watts usually supports several essentials together:

  • Refrigerator or freezer plus lights
  • Gas furnace blower or boiler circulator
  • Sump pump or well pump (surge watts matter)
  • Microwave or coffee maker (cycle with other loads)
  • One larger load at a time (for example, a window AC)

What usually cannot run All at once (even with 10,000 watts)

These loads commonly push you into overload if they overlap or start together:

  • Central air conditioning plus other major loads
  • Electric range/oven
  • Electric dryer
  • Electric water heater
  • Multiple space heaters

Quick planning table (typical watt ranges)

Use appliance nameplates for exact watts and starting amps.

Load Typical running watts Typical starting surge Planning tip
Refrigerator 150 to 800 1,200 to 2,000+ Start it first, then add loads
Sump pump 800 to 1,500 1,300 to 3,000+ Larger pumps surge higher
Well pump 1,000 to 2,500 2,000 to 5,000+ Surge is the limiter
Microwave 900 to 1,500 Low Input watts exceed “cooking watts”
Window AC 600 to 1,500 1,500 to 3,500+ Run one cooling load at a time

Important note for the All Power APG3014 (2000-watt class)

If you are using the APG3014 specifically, plan on only small loads:

  • A few LED lights
  • Phone/laptop chargers
  • A small fan
  • A small TV

Avoid running refrigerators, sump pumps, space heaters, or microwaves on a 2000-watt class generator unless the appliance wattage and starting surge are clearly within the generator’s ratings.

Why it matters

Generator sizing is about both running watts and starting surge; matching the generator to the loads prevents breaker trips, stalled motors, and unsafe improvising with cords or connections.

Last updated: February 2026

For a portable generator like the All Power APG3014, the most reliable “brand” is the one that delivers stable power at your required wattage and is maintained on schedule. In real-world use, correct sizing, overload protection, and routine service matter more than the logo; follow the APG3014 owner's manual to get the reliability this model is designed to deliver.

What reliability looks like on the APG3014

Your APG3014 includes features and procedures in the manual that directly support dependable starting and safe output.

Key reliability points to use:

  • Start with no loads connected; connect appliances only after the engine is running
  • Disconnect loads before shutdown to prevent arcing and nuisance trips
  • Use the fuel valve (cock) correctly: ON to run, OFF to stop and store
  • Keep the air cleaner clean; a dirty filter causes hard starting and poor running
  • Use the oil protection system (oil sensor/low-oil shutdown) as a safeguard, not a substitute for checking oil

How to compare “most reliable” brands for portable generators

When you compare brands, compare the specific model features and support, not marketing claims.

Compare item What to look for Why it matters
Running vs. surge watts Clear ratings that match your loads Prevents overload and voltage drop
Protection Overload/AC protection, low-oil shutdown Reduces engine and connected-load damage
Fuel system design Easy draining, accessible carburetor Less trouble from stale fuel
Maintenance access Air filter and spark plug are easy to reach Increases on-time maintenance

What we recommend for dependable performance

Use these practices to make the APG3014, or any comparable portable generator, as reliable as possible:

  • Keep gasoline fresh; drain or treat fuel before storage
  • Change oil on schedule and check level before each use
  • Clean the air filter regularly (more often in dusty conditions)
  • Tighten and inspect electrical connections if output is intermittent
  • Avoid running continuously at maximum load; leave headroom for starting watts

Why it matters

Most “unreliable generator” problems come from overload, stale fuel, and skipped maintenance. When the generator is sized correctly and serviced routinely, a portable unit like the APG3014 starts more consistently and holds steadier output.

Last updated: February 2026

Symptoms for treadmills

Choose a symptom to see related treadmill repairs.

Main causes: no power, bad power cord, tripped or faulty overload switch, bad power switch, wiring failure, bad motor co…

Main causes: damaged walking belt, improper belt tension, bad roller bearing…

Main causes: faulty sensors, wiring failure, bad control console…

Main causes: damaged walking belt, improper belt tension, lack of belt lubricant, bad drive motor…

Main causes: bad control console, wiring failure, bad motor control board…

Main causes: rear roller out of alignment, damaged walking belt, bad roller…

Main causes: missing safety key, bad control console, wiring failure, faulty motor control board, bad drive motor…

Repair guides for treadmills

These step-by-step repair guides will help you safely fix what’s broken on your treadmill.

How to replace a treadmill walking board

How to replace a treadmill walking board

A worn-out walking board creates friction with the walking belt and causes the belt to slow down during use. Replace the…

Repair time and Difficulty

 30 minutes or less
How to replace a treadmill drive motor

How to replace a treadmill drive motor

A defective drive motor won't run when activated by the motor controller. Replace the treadmill drive motor if it doesn'…

Repair time and Difficulty

 15 minutes or less
How to replace a treadmill walking belt

How to replace a treadmill walking belt

A worn walking belt will begin to slow down during use. If your treadmill walking belt is worn out, replace it using the…

Repair time and Difficulty

 45 minutes or less

Articles and videos for treadmills

Use the advice and tips in these articles and videos to get the most out of your treadmill.

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

Treadmill common questions

Treadmill common questions

These answers to common questions can help you make the most of your treadmill.…

Parts & More

Band Saw
Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Chainsaw
Electric Water Heater
Front-Engine Lawn Tractor
Gas Range
Gas Snowblower
Gas Walk-Behind Mower
Parts
Room Air Conditioner
Side-By-Side Refrigerator
Washer