How to reset Kenmore 11094834201 dryer?
To reset a Kenmore 11094834201 gas dryer, we power-cycle it: turn the dryer off, unplug it (or switch the breaker off) for 1 minute, then restore power and try a normal cycle. This clears many control glitches and false error conditions.
- Turn the dryer OFF.
- Unplug the power cord (or turn the breaker OFF).
- Wait 60 seconds.
- Plug back in (or turn the breaker ON).
- Close the door firmly and select a Timed Dry cycle.
- Press Start.
A reset will not fix a failed door switch, drive system problem, or heat system failure. Check these common causes next:
- Door not latching; inspect the door strike and latch alignment (the door must close tightly).
- No drum movement or a squeal/grind; the belt, rollers, or idler can bind.
- Motor hums but drum will not turn; the drive system may be stuck.
- Dryer runs but has heat issues; ignition components can fail on gas models.
| Symptom | What it often points to | Example part for this model |
|---|---|---|
| Door will not stay shut | Worn strike/latch | Strike 279570 |
| Squealing, thumping, hard-to-turn drum | Worn drum support rollers | Support WPW10314173 |
| Belt slack, drum not turning smoothly | Worn idler pulley | Dryer idler pulley 279640 |
| No heat or intermittent ignition | Weak gas valve coils or igniter/sensor | Dryer valve coil kit 279834, igniter 279311, dryer radiant sensor WP338906 |
A proper reset is a fast first step, but repeated “reset and retry” can hide a mechanical drag or ignition issue that gets worse over time. Checking the door latch, drum support, and gas ignition parts helps you fix the root cause instead of chasing symptoms.
If your dryer is showing an error code or acting like the controls are locked up, use our Kenmore 110 series electronic control model dryer error codes guide to match the code to the most likely failure.
Last updated: February 2026
What is the PF code on a Kenmore 11094834201?
The PF code on your Kenmore 11094834201 gas dryer means the dryer detected a power interruption (power failure) during operation. Clear it by pressing Stop/Cancel (or Pause/Cancel) twice, then restart the cycle.
- Press Stop/Cancel twice to clear the display.
- If the dryer was running, reselect your cycle and press Start.
- Check that the power cord is fully seated at the outlet (no loose plug).
- Reset the home breaker by switching the dryer circuit OFF then ON.
- Avoid using an extension cord or power strip; plug the dryer directly into the wall outlet.
PF is usually not a “bad part” code; it is almost always related to power stability.
| Likely cause | What you may notice | What to do |
|---|---|---|
| Brief outage or flicker | PF appears after a storm or blink | Clear code and restart |
| Loose outlet or plug | PF happens when the dryer vibrates | Reseat plug; inspect outlet |
| Tripped/weak breaker | Dryer stops mid-cycle | Reset breaker; monitor |
| Intermittent internal connection | PF repeats even with stable power | Inspect wiring connections (unplug first) |
If PF returns frequently (for example, multiple times per week), focus on vibration-related power loss and internal connections.
- Confirm the dryer is level and not “walking.”
- Inspect the power cord and terminal block area for heat damage (unplug first).
- If the drum support system is worn, the dryer can vibrate more than normal; consider checking the support WPW10314173 and the dryer idler pulley 279640.
Repeated power interruptions can stop a cycle before clothes are dry and can also point to a loose electrical connection that should be corrected for reliable, safe operation.
Last updated: February 2026
What is the cubic foot of my Kenmore dryer model 11094834201?
Kenmore gas dryer model 11094834201 is a full-size dryer; most full-size Kenmore 110-series gas dryers run about 7.0 cubic feet of drum capacity. For an exact number, the most reliable method is to calculate capacity from your drum’s inside measurements.
Use the drum’s inside dimensions to compute cubic feet.
- Unplug the dryer and shut off the gas supply
- Measure inside drum diameter (inches)
- Measure inside drum depth (front to back, inches)
- Calculate cubic inches:
3.1416 × (diameter ÷ 2)² × depth - Convert to cubic feet:
cubic inches ÷ 1728
If you are comparing specs across similar Kenmore models, matching major drum-area parts keeps you in the right capacity family.
| What you need | Best check | What it tells you |
|---|---|---|
| Exact cubic feet | Drum diameter and depth | True capacity calculation |
| Same dryer platform | Drum and bulkhead part IDs | Confirms drum and front support design |
| Similar airflow and tumbling | Drum baffle part ID | Confirms lift pattern and airflow style |
Capacity affects drying performance. Loads that exceed the drum’s practical capacity restrict airflow, increase dry time, and can contribute to overheating or cycling temperature issues.
For heat-related symptoms on a gas dryer, follow our gas dryer wont heat troubleshooting video.
Last updated: February 2026