Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Kenmore 11060012002 commercial dryer

Kenmore 11060012002 commercial dryer Parts

Here are the diagrams and repair parts for Kenmore 11060012002 commercial dryer, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 11060012002 Commercial Dryer

  • Dryer Terminal Block for Kenmore 11060012002 - Part WP3397659

    Cabinet parts diagram

    Dryer Terminal Block

    Part #3397659

    Replaced by #WP3397659

    Info Icon
    Manufacturer substitution
    This part replaces 3397659. Substitute parts can look different from the original.
    In Stock
    $17.68
    10% OFF Phone Price : $19.68Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Terminal Block Screw And Nut Set for Kenmore 11060012002 - Part 279393

    Cabinet parts diagram

    Dryer Terminal Block Screw And Nut Set

    In Stock
    $31.10
    16% OFF Phone Price : $37.10Info Icon
    Minus Item
    Qty
    Plus Item
  • Appliance Spray Paint (white) for Kenmore 11060012002 - Part 350930

    Bulkhead parts diagram

    Appliance Spray Paint (white)

    Part #350930
    This item is not returnable
    In Stock
    $26.00
    19% OFF Phone Price : $32.00Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Drum Seal, Rear for Kenmore 11060012002 - Part 239087

    Bulkhead parts diagram

    Seal

    Part #8066085

    Replaced by #239087

    Info Icon
    Manufacturer substitution
    This part replaces 8066085. Substitute parts can look different from the original.
    In Stock
    $58.90
    9% OFF Phone Price : $64.90Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Leveling Leg for Kenmore 11060012002 - Part 49621

    Cabinet parts diagram

    Foot

    Part #3392100

    Replaced by #49621

    Info Icon
    Manufacturer substitution
    This part replaces 3392100. Substitute parts can look different from the original.
    In Stock
    $9.22
    10% OFF Phone Price : $10.22Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Cabinet Clip for Kenmore 11060012002 - Part WP98234

    Cabinet parts diagram

    Dryer Cabinet Clip

    Part #98234

    Replaced by #WP98234

    Info Icon
    Manufacturer substitution
    This part replaces 98234. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $8.62
    10% OFF Phone Price : $9.62Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Top Panel Clip for Kenmore 11060012002 - Part WP18776

    Cabinet parts diagram

    Dryer Top Panel Clip

    Part #18776

    Replaced by #WP18776

    Info Icon
    Manufacturer substitution
    This part replaces 18776. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $9.27
    10% OFF Phone Price : $10.27Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Motor Clamp for Kenmore 11060012002 - Part WP660658

    Cabinet parts diagram

    Dryer Motor Clamp

    Part #660658

    Replaced by #WP660658

    Info Icon
    Manufacturer substitution
    This part replaces 660658. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $7.43
    12% OFF Phone Price : $8.43Info Icon
    Minus Item
    Qty
    Plus Item
  • Laundry Appliance Push Nut for Kenmore 11060012002 - Part WP90296

    Bulkhead parts diagram

    Clip

    Part #90296

    Replaced by #WP90296

    Info Icon
    Manufacturer substitution
    This part replaces 90296. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.76
    17% OFF Phone Price : $5.76Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Motor Clamp for Kenmore 11060012002 - Part WP3404162

    Cabinet parts diagram

    Dryer Motor Clamp

    Part #3404162

    Replaced by #WP3404162

    Info Icon
    Manufacturer substitution
    This part replaces 3404162. Substitute parts can look different from the original.
    In Stock
    $7.43
    12% OFF Phone Price : $8.43Info Icon
    Minus Item
    Qty
    Plus Item

Kenmore Commercial Dryer 11060012002 FAQs

Unplug your Kenmore dryer model 11060012002 for 5 minutes, then plug it back in and try a cycle. This power reset clears many temporary control and motor-start issues; if it still will not run, use the troubleshooting steps in the 11060012002 owner's manual.

Quick reset and restart checklist

  • Turn the dryer OFF.
  • Unplug the power cord (or switch the breaker OFF).
  • Wait 5 minutes.
  • Restore power.
  • Close the door fully, then press PUSH TO START firmly.
  • If it is coin-operated, confirm the meter-case service door is closed and locked.

If it still will not start (most common causes)

A reset will not fix an open safety switch, blown thermal device, or a drive problem. Check these items next:

  • Door not registering closed: test the door switch; replace if it fails continuity testing.
  • Overheating safety opened: inspect venting and test the thermal cut-off components.
  • No airflow restriction check: clean the lint screen area and confirm the exhaust vent is not crushed or clogged.
  • Drive system jammed: a seized roller or idler can prevent the motor from starting.

Parts that commonly solve “won’t start” after a reset

Symptom What to check Example part for this model
Push-to-start does nothing, door must be shut Door switch Door switch WP3406105
Runs briefly then stops, or overheats Thermal cut-off/high-limit circuit Dryer thermal cut-off fuse kit 279816
Hums but drum will not turn Belt and idler/rollers Dryer drum belt 341241 or dryer repair kit 4392065

Why it matters

On a commercial Kenmore dryer like 11060012002, a simple power reset is a fast first step, but repeated no-start problems usually point to a safety device (door switch, thermal cut-off) or airflow/drive wear. Fixing the root cause prevents downtime and repeat shutdowns.

Last updated: February 2026

To find the exact model of your Kenmore dryer, look for the model and rating label on the appliance itself (not the owner’s manual). On model 11060012002, the label is typically on the back of the dryer cabinet; write the full number exactly as shown, including all digits.

Where to look on the dryer

Check these common label locations first:

  • Back of the dryer cabinet (often near the center or upper area)
  • Inside the door opening on the cabinet frame
  • Behind the lower access panel (if your unit has one)
  • Inside the meter-case area on commercial/coin models (after opening the access door)

For diagrams and access details specific to this commercial dryer, use the 11060012002 owner's manual.

How to record the model number correctly

Use this quick checklist so you get the right parts the first time:

  • Copy the model number exactly (for example, 11060012002, not a shortened version)
  • Also record the serial number from the same label
  • Take a clear photo of the label in case the print is worn
  • If the label is hard to read, use a flashlight and wipe dust off gently

Model number vs. other numbers (what to ignore)

What you see What it is Use it for parts?
Model number (example: 11060012002) Exact dryer identity Yes
Serial number Production identifier Sometimes
Timer/coin box key number Key/lock identifier No
Part numbers on components Individual part IDs No

Why it matters

Kenmore dryers often share a similar look across multiple model numbers, but parts like a door switch, thermal cut-off, or drum belt can vary by model. Using the exact model number ensures the correct match for items such as the dryer drum belt 341241 and other drive or heating components.

Last updated: February 2026

In the Kenmore 11060012002 commercial dryer, heating element failure is most often caused by restricted airflow (lint-clogged exhaust), overheating from poor cycling control, or an electrical problem such as a broken element wire or a grounded/shorted circuit. Use the wiring and heat checks in the 11060012002 owner's manual to pinpoint the cause.

Common causes (and what to check first)

  • Blocked exhaust vent or lint buildup: A clogged vent makes the heater run hotter and longer than designed.
  • Lint accumulation inside the cabinet (blower or motor area): Reduces airflow and raises internal temperatures.
  • Failed temperature control: A bad operating thermostat or high-limit thermostat can cause overheating or improper cycling.
  • Broken element wire or loose connection: The manual specifically calls out checking for a broken element wire.
  • Grounded wiring or component: A grounded control panel or harness can create abnormal current flow and damage heater circuits.

Quick diagnostic path for “no heat”

  1. Confirm airflow: Clean the lint screen; inspect the full exhaust run for blockage or crushed ducting.
  2. Verify power supply: Check line fuses/switches; many electric dryers can run but not heat if one leg of power is lost.
  3. Inspect heater wiring: Look for burnt terminals, loose spade connectors, or a broken element wire.
  4. Test thermostats for continuity: The manual procedure commonly uses a continuity test (or a temporary jumper test during diagnosis).
  5. Check for grounding/shorts: Inspect the main wiring harness at the element terminals for signs of rubbing, scorching, or contact with metal.

Parts that commonly relate to overheating and heater damage

Symptom Most likely area Example part for this model
No heat, dryer runs Heater circuit safety opened Dryer thermal cut-off fuse kit 279816
Overheats, cycles oddly Temperature regulation Dryer operating thermostat WP3387134
Shuts heat down too late Safety limit control Dryer high-limit thermostat WP3977767

Why it matters

A heating element usually fails as a result of another problem, especially airflow restriction. Fixing the root cause (venting, lint buildup, thermostat cycling, wiring condition) helps prevent repeat element and fuse failures and reduces fire risk.

Last updated: February 2026

On Kenmore dryers like model 11060012002, an E1 code points to an exhaust temperature problem (the dryer senses the exhaust air temperature is out of the normal range). The most common causes are a restricted venting system or a failing temperature sensor circuit.

What to check first (fast, most common fixes)

  • Clean the lint screen and confirm strong airflow at the outside vent hood.
  • Inspect the entire vent run for kinks, crushed flex duct, lint buildup, or a stuck vent flap.
  • Make sure the dryer is not pushed too tightly against the wall (it can pinch the exhaust).
  • If installed in a closet or recessed area, confirm the installation clearances and venting match the requirements in the 11060012002 owner’s manual.
  • Run a timed dry cycle with the vent disconnected briefly (only long enough to test airflow); if the code stops, the house venting is the issue.

Parts that commonly relate to exhaust temperature sensing

If airflow is good and E1 returns, the temperature control parts in the heater/exhaust circuit are the next place to look.

  • Operating thermostat: regulates normal cycling temperature (see dryer operating thermostat WP3387134).
  • High-limit thermostat: opens if the heater area overheats.
  • Thermal cut-off: opens if severe overheating occurs.

Quick symptom guide

What you notice Most likely issue What to do
Weak airflow, long dry times, hot cabinet Vent restriction Clean/shorten venting, replace crushed duct
E1 appears soon after start, airflow seems normal Sensor/thermostat circuit issue Test thermostats and wiring with a meter
Dryer overheats, then stops heating Safety device opened Check venting first, then test safety parts

Why it matters

E1 is often the dryer warning you that heat is not being carried out correctly. Fixing venting and temperature-control issues helps prevent repeated shutdowns, long dry times, and overheating stress on the heater and motor.

Last updated: February 2026

The Kenmore commercial dryer model 11060012002 is a full-size, 27-inch class dryer. Most dryers in this design family measure about 27 inches wide, about 27 to 29 inches deep, and about 43 to 44 inches tall; confirm the exact cabinet dimensions in the 11060012002 owner's manual.

Typical dimensions you can expect

These are the most common exterior size ranges for a Kenmore 110-style (Whirlpool-built) dryer like model 11060012002:

  • Width: ~27 inches
  • Depth: ~27 to 29 inches (often deeper with the vent elbow installed)
  • Height: ~43 to 44 inches (to the top of the cabinet)
  • Exhaust outlet: rear outlet location (affects depth and clearance planning)

How to confirm the exact size for your installation

Use these quick checks so your dryer fits the space and vents correctly:

  • Check the model and rating plate for clearance notes (commonly on the back of the dryer).
  • Measure width, height, and depth at the widest points (include knobs and door edge).
  • Add space for the power cord and vent connection behind the cabinet.
  • Plan for side and rear clearances listed for the unit.
  • If the dryer sits in a closet or recessed area, follow the spacing guidance in the manual.

Space planning cheat sheet

What you are sizing What to measure/include Why it matters
Cabinet width Left-to-right at the widest point Fit between walls/cabinets
Cabinet depth Front-to-back plus vent elbow Prevents crushed/kinked venting
Cabinet height Floor to top of cabinet Fit under shelves and counters
Rear clearance Space for vent and cord Airflow, safety, easier service

Why it matters

Correct sizing is not just about fitting the opening; it also helps you route the exhaust with fewer bends and less crushing or kinking, which supports better airflow and more consistent drying performance.

Last updated: February 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Bottom-Mount Refrigerator
Central Air Conditioner
Garage Door Opener
Gas Range
Gas Snowblower
Parts
Top-Mount Refrigerator
Treadmill
Washer