Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Maytag MED5500FW1 electric dryer

Maytag MED5500FW1 electric dryer Parts

Here are the diagrams and repair parts for Maytag MED5500FW1 electric dryer, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for MED5500FW1 Electric Dryer

  • Whirlpool Dryer Drum Support Roller Shaft for Maytag MED5500FW1 - Part WPW10359272

    Bulkhead parts diagram

    Dryer Drum Support Roller Shaft

    Part #W10359272

    Replaced by #WPW10359272

    Info Icon
    Manufacturer substitution
    This part replaces W10359272. Substitute parts can look different from the original.
    In Stock
    $42.43
    12% OFF Phone Price : $48.43Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Drum Support Roller Shaft for Maytag MED5500FW1 - Part WPW10359271

    Bulkhead parts diagram

    Dryer Drum Support Roller Shaft

    Part #W10359271

    Replaced by #WPW10359271

    Info Icon
    Manufacturer substitution
    This part replaces W10359271. Substitute parts can look different from the original.
    In Stock
    $44.08
    12% OFF Phone Price : $50.08Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Idler Spring for Maytag MED5500FW1 - Part WPW10446781

    Cabinet parts diagram

    Dryer Idler Spring

    Part #W10446781

    Replaced by #WPW10446781

    Info Icon
    Manufacturer substitution
    This part replaces W10446781. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $18.64
    10% OFF Phone Price : $20.64Info Icon
    Minus Item
    Qty
    Plus Item
  • Whirlpool Washer Door Hinge for Maytag MED5500FW1 - Part WPW10208415

    Door parts diagram

    Washer Door Hinge

    Part #W10208415

    Replaced by #WPW10208415

    Info Icon
    Manufacturer substitution
    This part replaces W10208415. Substitute parts can look different from the original.
    In Stock
    $103.15
    10% OFF Phone Price : $115.15Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Terminal Block for Maytag MED5500FW1 - Part WP3397659

    Cabinet parts diagram

    Dryer Terminal Block

    Part #3397659

    Replaced by #WP3397659

    Info Icon
    Manufacturer substitution
    This part replaces 3397659. Substitute parts can look different from the original.
    In Stock
    $17.68
    10% OFF Phone Price : $19.68Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Terminal Block Screw And Nut Set for Maytag MED5500FW1 - Part 279393

    Cabinet parts diagram

    Dryer Terminal Block Screw And Nut Set

    In Stock
    $31.10
    16% OFF Phone Price : $37.10Info Icon
    Minus Item
    Qty
    Plus Item
  • Appliance Spray Paint (white) for Maytag MED5500FW1 - Part 350930

    Optional parts (not included) diagram

    Appliance Spray Paint (white)

    Part #350930
    This item is not returnable
    In Stock
    $26.00
    19% OFF Phone Price : $32.00Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Heater Box for Maytag MED5500FW1 - Part W10802681

    Bulkhead parts diagram

    Assembly, Weld Heater Box

    Part #W10891205

    Replaced by #W10802681

    Info Icon
    Manufacturer substitution
    This part replaces W10891205. Substitute parts can look different from the original.
    In Stock
    $89.52
    6% OFF Phone Price : $95.52Info Icon
    Minus Item
    Qty
    Plus Item
  • Whirlpool Dryer Electronic Control Board for Maytag MED5500FW1 - Part W11537215

    Cabinet parts diagram

    Plant Prog A

    Part #W10847936

    Replaced by #W11537215

    Info Icon
    Manufacturer substitution
    This part replaces W10847936. Substitute parts can look different from the original.
    In Stock
    $171.80
    7% OFF Phone Price : $183.80Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Leveling Leg for Maytag MED5500FW1 - Part 49621

    Cabinet parts diagram

    Dryer Extended-length Leveling Leg

    Part #279810

    Replaced by #49621

    Info Icon
    Manufacturer substitution
    This part replaces 279810. Substitute parts can look different from the original.
    In Stock
    $9.22
    10% OFF Phone Price : $10.22Info Icon
    Minus Item
    Qty
    Plus Item

Maytag Electric Dryer MED5500FW1 FAQs

To hard reset your Maytag MED5500FW1 electric dryer, unplug it (or switch the breaker OFF) for 1 minute, then restore power and start a cycle. This clears many temporary control glitches without replacing parts; use the MED5500FW1 owner's manual for model-specific control and cycle details.

Hard reset steps (MED5500FW1)
  • Turn the dryer OFF and make sure the cycle has stopped.
  • Unplug the power cord from the wall outlet.
  • If you cannot reach the plug, switch the dryer’s circuit breaker OFF.
  • Wait 60 seconds.
  • Restore power (plug back in or turn breaker ON).
  • Select a normal cycle and press Start to confirm the control responds.
If the reset does not fix it

A reset helps with a “stuck” control, but it will not correct a heating or airflow problem. Check these common causes next:

  • House power issue (electric dryers need full 240V supply; a partial power loss can cause odd behavior).
  • Restricted venting or lint buildup (can cause long dry times and overheating symptoms).
  • Overheating protection opening (a blown fuse or thermostat issue can stop heat or stop the dryer).
  • Moisture sensor bars coated with residue (auto cycles may end early).
Quick symptom-to-part check
Symptom after reset Most common area to inspect Example part for this model
Runs but no heat Heating circuit Dryer heating element WP3387747
Stops heating, may run but won’t dry Overheat protection, airflow Thermal fuse W10909685
Auto cycles end too soon Sensor circuit Dryer moisture sensor WP3387223
Why it matters

Resetting first prevents unnecessary part replacement. If the dryer immediately acts up again, the pattern of symptoms (no heat, long dry time, early shutoff) points us toward the heating element, thermal fuse, moisture sensor, or venting so you can troubleshoot efficiently.

Last updated: February 2026

On a Maytag MED5500FW1 electric dryer, the F-01 error points to a problem with the main electronic control (machine control board). It typically shows up when the control can’t reliably run the cycle, read inputs, or store cycle settings.

What you should do first
  • Unplug the dryer (or switch off the breaker) for 1 minute, then restore power and try a cycle again.
  • If the code returns immediately, stop using the dryer until you check airflow and wiring connections.
  • Confirm the door is fully closed and the Start button is pressed firmly.
  • Make sure the vent is not crushed or kinked behind the dryer.
  • If the dryer will not start at all, verify the house breaker is not tripped (electric dryers often need a full 240V supply).

For model-specific operating checks and control panel behavior, follow the steps in the MED5500FW1 owner's manual.

Common causes of an F-01 code

F-01 is most often tied to the control board itself, but we also see it triggered by power or connection issues.

  • Power interruption or unstable supply (tripped breaker, loose cord/terminal block connection)
  • Loose or damaged wire harness connection at the control
  • Moisture or corrosion at connectors (especially after a move or storage)
  • Control board internal failure (memory or relay fault)
Quick troubleshooting guide (what to check vs. what it means)
What you notice Most likely direction What we recommend
F-01 comes back right after reset Control or power issue persists Check power, then inspect wiring to control
Dryer starts, then stops and shows F-01 Control losing input or failing under load Check venting and connections; plan for control diagnosis
Dryer won’t start and shows F-01 Control not enabling motor circuit Verify 240V supply; inspect terminal block and harness
Why it matters

The control board manages heat timing, motor operation, and cycle logic. When it faults, the dryer can stop mid-cycle, over-dry, or fail to heat properly. Fixing airflow and power issues first prevents repeat failures and nuisance codes.

If you’re seeing other codes along with F-01, use our Maytag bravos dryer error codes reference to compare symptoms and narrow the diagnosis.

Last updated: February 2026

The Maytag MED5500FW1 is an electric dryer; its drum capacity is measured in cubic feet, but the capacity value is not shown in the installation measurements we have for this model. For the exact capacity rating, we recommend checking the model’s specifications in the MED5500FW1 owner's manual.

How to find the exact capacity for MED5500FW1

We use the capacity listed in the model specs (not the cabinet size). Check these common places:

  • The specifications section in the MED5500FW1 owner's manual
  • The model/serial tag area (often inside the door opening) for the full model ID
  • Product literature that lists drum capacity (cu. ft.)
  • If you are comparing dryers, use capacity plus venting and cycle type (timed vs. sensor dry)
Capacity vs. dimensions (they are different)

The installation guide provides cabinet dimensions for fit and clearances, not drum capacity. For MED5500FW1, the guide shows approximate exterior measurements:

Measurement type What it helps with Typical value shown in install guide
Width Fit in closet/recess 27 in (686 mm)
Height Fit under shelves/cabinets 38 3/4 in min to 39 in max (984 to 990 mm)
Depth/venting space Room for vent connection Determined by vent route and clearance
Why it matters

Capacity affects how well the dryer handles bulky items (comforters, towels) and how efficiently loads dry. Using the correct capacity spec also helps when matching a washer and dryer set and planning laundry room space.

Last updated: February 2026

Most Maytag washers last 10 to 13 years with normal household use. Even though your page is for the Maytag MED5500FW1 electric dryer, that washer lifespan range is a solid expectation for Maytag laundry appliances when they are installed correctly and maintained; see the MED5500FW1 installation guide for setup basics that also protect laundry performance.

Typical lifespan by washer type

Washer design and usage patterns affect longevity.

Washer type Typical average lifespan
Top-load (agitator or impeller) 10 to 13 years
Front-load 10 to 13 years
Compact/stacked units 8 to 12 years
What helps a Maytag washer reach (or beat) 10 to 13 years

We see the biggest gains from preventing vibration, overload, and moisture-related issues.

  • Keep the washer level to reduce bearing and suspension wear
  • Avoid overloading; heavy loads strain the drive system
  • Use the right detergent amount (especially HE detergent in HE machines)
  • Leave the door/lid open after use to reduce odor and gasket/mold issues
  • Clean the tub and dispensers on a regular schedule
  • Fix small leaks quickly to prevent corrosion and electrical damage
Quick “replace vs. repair” rule of thumb

Age and symptom severity usually decide the best path.

  • Under 5 years: repairs are usually worth it
  • 5 to 10 years: repair if it is a single, clear failure (pump, belt, lid lock)
  • 10+ years: consider replacement if multiple issues stack up (noise + leaks + poor spin)
Why it matters

A washer near end-of-life often shows longer cycle times, poor spin-out, louder operation, and repeat service needs. Staying within proper installation and load limits reduces stress on the motor, bearings, and suspension, which is what most often determines whether you get 10 years or 13.

Last updated: February 2026

On your Maytag MED5500FW1 electric dryer, we find the model and serial tag first, then use that information to match the correct part number. The tag is typically on the door opening (door jamb) or on the cabinet opening just inside the door.

Where to look on the MED5500FW1

Check these common label locations (in order):

  • Door opening: along the door jamb or the front frame
  • Just inside the door: on the cabinet opening near the lint screen housing
  • Rear panel: a rating label on the back of the dryer cabinet
  • Side panel edge: near the front seam where the cabinet meets the front panel
How to use the label to get the right part

Once you find the tag, use the model number and serial number to confirm the exact version of your dryer, then match parts by description.

  • Write down the full model number (MED5500FW1) and serial number
  • Match the part by name (example: heating element, thermal fuse, drum roller)
  • Compare the part number and any notes for your model variation
  • If you are replacing a failed heat component, inspect wiring and terminals for heat damage
Quick examples of “part number” vs “part name”
What you see What it means Example for this model
Model number Identifies the dryer MED5500FW1
Serial number Identifies production series Used to confirm correct part fit
Part name What the component does Dryer heating element
Part number / part ID The exact replacement identifier Dryer heating element WP3387747
Why it matters

Maytag dryers can have small production changes within the same model family. Using the model and serial tag prevents ordering a look-alike part that mounts differently, uses a different connector, or has a different temperature rating.

Helpful reference

For diagrams and label details, use the MED5500FW1 installation guide.

Last updated: February 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Chipper/Shredder
Dryer
Electric Range
Gas Grill
Gas Snowblower
Outdoor Grill
Parts
Refrigerator
Vacuum Cleaner
Washer
Water Softener
Weight System