Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Maytag MED9600SQ0 dryer

Maytag MED9600SQ0 dryer Parts

Here are the diagrams and repair parts for Maytag MED9600SQ0 dryer, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for MED9600SQ0 Dryer

  • Dryer Switch Kit for Maytag MED9600SQ0 - Part 279782

    Cabinet parts diagram

    Switch

    Part #3394881

    Replaced by #279782

    Info Icon
    Manufacturer substitution
    This part replaces 3394881. Substitute parts can look different from the original.
    In Stock
    $51.30
    10% OFF Phone Price : $57.30Info Icon
    Minus Item
    Qty
    Plus Item
  • Whirlpool Appliance Screw for Maytag MED9600SQ0 - Part WP488729

    Bulkhead parts diagram

    Screw

    Part #695240

    Replaced by #WP488729

    Info Icon
    Manufacturer substitution
    This part replaces 695240. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.93
    17% OFF Phone Price : $5.93Info Icon
    Minus Item
    Qty
    Plus Item
  • Whirlpool Appliance Screw for Maytag MED9600SQ0 - Part WP488729

    Screw

    Part #3390647

    Replaced by #WP488729

    Info Icon
    Manufacturer substitution
    This part replaces 3390647. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.93
    17% OFF Phone Price : $5.93Info Icon
    Minus Item
    Qty
    Plus Item
  • Whirlpool Appliance Screw for Maytag MED9600SQ0 - Part WP488729

    Bulkhead parts diagram

    Screw

    Part #487909

    Replaced by #WP488729

    Info Icon
    Manufacturer substitution
    This part replaces 487909. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.93
    17% OFF Phone Price : $5.93Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Terminal Block Wire Set for Maytag MED9600SQ0 - Part 279318

    Cabinet parts diagram

    Dryer Terminal Block Wire Set

    In Stock
    $61.34
    9% OFF Phone Price : $67.34Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Terminal Block Screw And Nut Set for Maytag MED9600SQ0 - Part 279393

    Cabinet parts diagram

    Dryer Terminal Block Screw And Nut Set

    In Stock
    $31.10
    16% OFF Phone Price : $37.10Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Leveling Leg for Maytag MED9600SQ0 - Part 49621

    Cabinet parts diagram

    Foot

    Part #3392100

    Replaced by #49621

    Info Icon
    Manufacturer substitution
    This part replaces 3392100. Substitute parts can look different from the original.
    In Stock
    $9.22
    10% OFF Phone Price : $10.22Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Leveling Leg for Maytag MED9600SQ0 - Part 49621

    Cabinet parts diagram

    Dryer Extended-length Leveling Leg

    Part #279810

    Replaced by #49621

    Info Icon
    Manufacturer substitution
    This part replaces 279810. Substitute parts can look different from the original.
    In Stock
    $9.22
    10% OFF Phone Price : $10.22Info Icon
    Minus Item
    Qty
    Plus Item
  • Washer Screw for Maytag MED9600SQ0 - Part WP90767

    Cabinet parts diagram

    Screw

    Part #3390814

    Replaced by #WP90767

    Info Icon
    Manufacturer substitution
    This part replaces 3390814. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.88
    17% OFF Phone Price : $5.88Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Drum for Maytag MED9600SQ0 - Part W10545924

    Bulkhead parts diagram

    Drum

    Part #697282

    Replaced by #W10545924

    Info Icon
    Manufacturer substitution
    This part replaces 697282. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $249.38
    5% OFF Phone Price : $261.38Info Icon
    Minus Item
    Qty
    Plus Item

Maytag Dryer MED9600SQ0 FAQs

The AF code on your Maytag MED9600SQ0 dryer points to an airflow restriction. We fix it by cleaning the lint screen and then clearing the entire exhaust path (lint housing, blower area, vent hose, and outside hood) so the dryer can move air and dry normally.

Quick fix checklist (start here)
  • Unplug the dryer (or switch off the breaker) before opening panels.
  • Clean the lint screen with warm water and a soft brush; remove any fabric softener film.
  • Disconnect the vent hose from the back of the dryer and remove packed lint.
  • Check the outside vent hood; make sure the flap opens fully and is not blocked.
  • Run a timed dry cycle for 5 to 10 minutes with the vent disconnected (brief test only) to see if airflow improves.
  • If airflow is still weak, inspect the blower housing and internal ducting.
What usually causes AF on MED9600SQ0
Cause What you notice What to do
Clogged lint screen or lint screen film Long dry times, AF appears mid-cycle Wash and dry the screen; clean the lint screen slot
Crushed or long vent hose Hot cabinet, poor airflow at hood Shorten/replace venting; avoid kinks
Lint buildup inside dryer Burning smell, weak airflow even with short vent Clean internal ducting and blower area
Temperature sensing issue AF persists with verified clear venting Check the thermistor and related wiring
Parts that can be involved (when cleaning is not enough)

If the venting is clear and AF keeps returning, we focus on airflow and temperature feedback parts:

Why it matters

Restricted airflow makes the dryer run hotter and longer, which can trip safety devices, increase energy use, and lead to repeated shutdowns or poor drying performance.

For model-specific access steps and panel removal guidance, follow the MED9600SQ0 owner's manual.

Last updated: January 2026

To reset an error code on your Maytag dryer model MED9600SQ0, we power-cycle the dryer: turn it off, disconnect power for a few minutes, then restore power and restart a cycle. If the code returns, the dryer is still detecting the underlying problem.

Reset steps (power-cycle)
  • Press Power/Cancel to stop the cycle.
  • Unplug the dryer (or switch the breaker off).
  • Wait 2 to 5 minutes.
  • Restore power.
  • Start a cycle and watch for the code to reappear.
If the code comes back right away

An error code that returns after a reset usually points to a real fault (heat, airflow, sensor, or drive system). Use these quick checks first:

  • Clean the lint screen and confirm strong airflow at the outside vent.
  • Avoid overloading; heavy loads can trigger moisture-sensing and temperature issues.
  • If the dryer is not heating, check for restricted venting and heat-system problems.
  • If the dryer tumbles poorly or squeals, inspect belt and drum support components.
  • If the dryer stops mid-cycle, check door closure and overheating symptoms.
Common parts tied to “won’t heat” or temperature-related codes
Symptom What to check Example part for MED9600SQ0
No heat or weak heat Heater circuit Dryer heating element WP3387747
Overheats, then shuts down Safety cutoffs Dryer thermal cut-off fuse kit 279973
Erratic temps, long dry times Temperature sensing Dryer thermistor WP8577274
Why it matters

Resetting clears the control’s temporary state, but it does not fix the condition that triggered the code. Addressing airflow, heating, and sensor issues helps prevent repeat errors, long dry times, and overheating.

For model-specific control panel behavior and any diagnostic steps, follow the MED9600SQ0 owner’s manual.

Last updated: January 2026

The most common Maytag dryer problem is no heat or long dry times caused by restricted airflow (lint buildup or a clogged vent). Poor airflow overheats the dryer and commonly leads to a blown thermal cut-off or thermostat, and it can also contribute to “won’t start” symptoms on models like Maytag MED9600SQ0.

What you’ll notice first
  • Clothes take much longer than normal to dry
  • Dryer runs but doesn’t heat (or heat is weak)
  • Dryer shuts off mid-cycle
  • Burning smell or the cabinet feels unusually hot
  • Dryer won’t start after overheating (some safety parts open and stop operation)
Quick checks that fix the root cause

Use these steps before replacing parts; they prevent repeat failures.

  • Clean the lint screen every load; wash it with mild soap if it has fabric softener residue
  • Inspect the vent hose for kinks, crushing, or excessive length
  • Clear lint from the exhaust duct and outside vent hood; confirm the flap opens fully
  • Run a timed heat cycle and check airflow outside; it should feel strong and steady
  • Avoid overloading; heavy loads restrict tumbling and airflow
Parts that commonly fail after airflow problems

If airflow is good and the dryer still won’t heat, these are frequent culprits on electric dryers.

Symptom Most likely area Example part for MED9600SQ0
Runs, no heat Heater circuit Dryer heating element WP3387747
Overheats, then no heat Safety cut-off Dryer thermal cut-off fuse kit 279973
Heat cycles erratically Temperature sensing Dryer thermistor WP8577274
Why it matters

Restricted venting is the #1 driver behind repeated heating failures. Fixing airflow first protects the heating element, thermostats, and wiring, and it also reduces dry time and energy use.

For model-specific operating tips and maintenance intervals, follow the MED9600SQ0 manual.

Last updated: January 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Air Compressor
Blender
Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Chainsaw
Elliptical Machine
Front-Engine Lawn Tractor
Gas Line Trimmer
Gas Walk-Behind Mower
Parts
Refrigerator
Side-By-Side Refrigerator
Table Saw
Treadmill
Washer