What is the PF code on a Kenmore 11072062102?
On a Kenmore 11072062102 gas dryer, the PF code means power failure. It shows up when the dryer loses power during a cycle or was plugged in during installation; clear it with STOP/CANCEL, then restart the cycle if needed (see the owner's manual).
- Press STOP/CANCEL to clear the display.
- Press START to restart the cycle if it was interrupted.
- Confirm the dryer is firmly plugged into the outlet.
- Check your home circuit breaker or fuse (use a time-delay fuse if your setup uses fuses).
- Make sure the door is fully closed and the cycle is selected.
PF is almost always caused by an interruption in incoming power, such as:
- A brief outage or flicker while the dryer is running
- A tripped breaker or blown fuse
- A loose power cord connection at the outlet
- Power being connected during installation or after moving the dryer
| Goal | What to press | Result |
|---|---|---|
| Clear the PF message | STOP/CANCEL | Removes the code from the display |
| Continue drying | START | Restarts the selected cycle |
A power interruption can stop the motor and controls mid-cycle, leaving clothes damp and sometimes making the dryer appear “dead” until the PF message is cleared and the cycle is restarted.
Last updated: February 2026
How do I reset my Kenmore dryer?
To reset your Kenmore gas dryer model 11072062102, clear the cycle and restore power: press STOP/CANCEL to end the cycle, then unplug the dryer for 1 minute and plug it back in. This resets the control and often clears a “PF” (power failure) message. See the 11072062102 owner's manual for the exact STOP/CANCEL and START behavior.
- Press STOP/CANCEL once to pause, or STOP/CANCEL to stop the dryer.
- If you already started a cycle and want to end it, press STOP/CANCEL twice.
- Unplug the dryer for 1 minute, then plug it back in.
- Re-select a cycle and press START (the dryer can shut off if START is not pressed within about 5 minutes of choosing a cycle).
- If the display shows “PF”, press STOP/CANCEL to clear it, then press START to restart.
These checks solve most “won’t run” complaints on this model:
- Confirm the dryer is plugged into a grounded 3-prong outlet.
- Check the house fuse/circuit breaker (use a time-delay fuse if applicable).
- Make sure the door is fully closed; a failed door switch can prevent starting.
- Verify a cycle is selected and START is pressed firmly.
- If the cycle was interrupted for more than 5 minutes, select the cycle again before pressing START.
| Symptom | What it affects | Part to consider |
|---|---|---|
| Dryer does nothing when you press START | Door safety circuit | Dryer door switch WP3406107 |
| Starts then stops, or acts erratic after power flicker | Power interruption handling | Use STOP/CANCEL to clear “PF” |
A proper reset clears a stuck cycle state and power-failure messages, but it also helps you quickly separate a simple control issue from a real start-interlock problem (like a door switch) or a power supply issue.
Last updated: February 2026
What size is a Kenmore Model 11072062102 dryer?
Kenmore gas dryer model 11072062102 is a full-size dryer in the 27-inch class. For the exact cabinet width, depth, and height for your specific unit, use the Dryer Dimensions section in the 11072062102 owner's manual; it also lists the clearances you must allow for safe venting.
Most full-size Kenmore gas dryers like model 11072062102 fit within these common planning ranges:
- Width: about 27 inches
- Depth (cabinet): about 29 to 31 inches
- Height: about 38 to 43 inches
- Behind dryer: allow at least 5 1/2 inches for the exhaust vent and elbow (a common installation requirement)
Use the manual for the official dimensions, then verify with a tape measure if you are fitting a tight closet.
- Measure width at the widest cabinet point (not the door swing)
- Measure depth from the back panel to the front of the cabinet (exclude knobs/handle if they stick out)
- Measure height from the floor to the top of the cabinet
- Add room for the gas connection and vent duct elbow behind the dryer
| Area | What to allow | Purpose |
|---|---|---|
| Dryer body | 27-inch class | Standard full-size fit |
| Rear clearance | 5 1/2 in minimum | Space for vent and elbow |
| Sides/top | 1 in recommended | Reduces noise transfer; improves service access |
Correct sizing is about more than the cabinet fitting. A gas dryer needs proper outdoor venting; the right rear clearance helps prevent crushed ducting, poor airflow, and long dry times.
Last updated: February 2026
What does CE mean on my dryer?
On Kenmore gas dryer model 11072062102, a CE display indicates the control is detecting a condition it cannot run through normally. Because CE is not a standard Kenmore 110-series code, treat it as a control-related stop and use the reset and power checks below before moving to component testing.
- Unplug the dryer or switch off the breaker for 5 minutes, then restore power.
- Plug the dryer into a grounded 3-prong outlet; do not use an adapter or extension cord.
- Use a dedicated 15- or 20-amp circuit (recommended for this type of dryer).
- Start a timed dry cycle and listen for the motor to start; note whether CE appears immediately or after pressing Start.
- If the code returns right away, stop using the dryer until the cause is found.
For the grounding and electrical requirements for this model, follow the 11072062102 owner's manual.
CE is often triggered by an input the control does not like (power stability, door input, or a wiring connection). These are the most common items to check on this model family:
- Door not registering closed (switch or latch alignment)
- Loose or damaged wiring at the console or door switch circuit
- Intermittent power or poor grounding
| When CE shows up | What to check next | Parts commonly involved |
|---|---|---|
| Immediately at power-up | Power supply, grounding, console connections | Wiring connections (harness) |
| When pressing Start | Door closed signal, Start input | Door switch |
| Mid-cycle | Power interruption, vibration-loosened connection | Harness connections |
If CE is paired with a no-start symptom, these parts are frequently tested for continuity and secure connections:
A gas dryer relies on correct grounding and reliable input signals (like the door-closed circuit) to run safely. Fixing power, door-switch, or wiring issues prevents repeat shutdowns and protects the control.
Last updated: February 2026