  • Crosley Dryer Terminal Block Cover for Maytag MED5800TW0 - Part W11736322

    Cabinet parts diagram

    Dryer Terminal Block Cover

    Part #3396795

    Replaced by #W11736322

    Info Icon
    Manufacturer substitution
    This part replaces 3396795. Substitute parts can look different from the original.
    In Stock
    $60.13
    Minus Item
    Qty
    Plus Item
  • Dryer Lint Chute Shield for Maytag MED5800TW0 - Part W11233063

    Bulkhead parts, optional parts (not included) diagram

    Shield

    Part #696302

    Replaced by #W11233063

    Info Icon
    Manufacturer substitution
    This part replaces 696302. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $22.33
    21% OFF Phone Price : $28.33Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Motor Bracket for Maytag MED5800TW0 - Part WP348780

    Cabinet parts diagram

    Base

    Part #348780

    Replaced by #WP348780

    Info Icon
    Manufacturer substitution
    This part replaces 348780. Substitute parts can look different from the original.
    In Stock
    $107.29
    Minus Item
    Qty
    Plus Item
  • Refrigerator Screw for Maytag MED5800TW0 - Part WP489463

    Bulkhead parts, optional parts (not included) diagram

    Refrigerator Terminal Block Enclosure Screw

    Part #489463

    Replaced by #WP489463

    Info Icon
    Manufacturer substitution
    This part replaces 489463. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.91
    17% OFF Phone Price : $5.91Info Icon
    Minus Item
    Qty
    Plus Item
  • Refrigerator Screw for Maytag MED5800TW0 - Part WP488627

    Cabinet parts diagram

    Screw

    Part #342055

    Replaced by #WP488627

    Info Icon
    Manufacturer substitution
    This part replaces 342055. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $8.31
    11% OFF Phone Price : $9.31Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Washer for Maytag MED5800TW0 - Part WP3388703

    Bulkhead parts, optional parts (not included) diagram

    Support Washer

    Part #3388703

    Replaced by #WP3388703

    Info Icon
    Manufacturer substitution
    This part replaces 3388703. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $8.54
    10% OFF Phone Price : $9.54Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Motor Wire Harness Connector for Maytag MED5800TW0 - Part 3395683

    Top and console parts diagram

    Dryer Motor Wire Harness Connector

    In Stock
    $33.07
    19% OFF Was : $40.77Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Drum Hole Plug for Maytag MED5800TW0 - Part 8066086

    Bulkhead parts, optional parts (not included) diagram

    Dryer Drum Hole Plug

    In Stock
    $9.87
    9% OFF Phone Price : $10.87Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Clip for Maytag MED5800TW0 - Part 279771

    Bulkhead parts, optional parts (not included) diagram

    Clip

    Part #3398161

    Replaced by #279771

    Info Icon
    Manufacturer substitution
    This part replaces 3398161. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $12.88
    13% OFF Phone Price : $14.88Info Icon
    Minus Item
    Qty
    Plus Item
  • Appliance Cap Screw for Maytag MED5800TW0 - Part W11693756

    Top and console parts diagram

    Refrigerator Capacitor Screw

    Part #WP487240

    Replaced by #W11693756

    Info Icon
    Manufacturer substitution
    This part replaces WP487240. Substitute parts can look different from the original.
    In Stock
    $45.15
    Minus Item
    Qty
    Plus Item

Maytag Dryer MED5800TW0 FAQs

No. Maytag dryers, including the Maytag MED5800TW0, do not come with a lifetime warranty; coverage is based on the warranty terms that came with your dryer. For the most accurate details for your unit, we recommend checking the warranty section in your owner's manual.

What warranty coverage typically includes

Warranty terms vary by model and purchase date, but most dryer warranties are limited-time coverage and may separate coverage for parts vs. labor.

Common items you may see in warranty paperwork:

  • Limited coverage period (often 1 year) for parts and labor
  • Longer limited coverage on specific components (varies by model)
  • Exclusions for normal wear items (for example, drum belts)
  • Requirements for proper installation, venting, and maintenance
  • Proof of purchase requirements

Parts that are usually considered wear items

Even when a dryer is under warranty, some components are commonly treated as maintenance or wear items. For MED5800TW0, examples of frequently replaced wear-related parts include:

Quick check: warranty vs. repair decision

Use this simple guide to decide your next step.

Situation Best next step
Dryer is within the warranty period in your paperwork Follow the warranty instructions in your documents before replacing parts
Dryer is out of warranty Troubleshoot the symptom, then replace the failed part
Unsure what failed Start with airflow and heat checks, then inspect common wear parts

Why it matters

Warranty coverage affects whether you should replace a part yourself or follow the warranty process first. It also helps set expectations because many dryer problems are caused by wear items (belt, rollers, idler) or airflow restrictions rather than a covered defect.

Last updated: February 2026

On a Maytag MED5800TW0 dryer, the L2 code points to a power supply problem, most often a missing or weak L2 leg of the 240-volt supply. The dryer may run but not heat, or it may stop and display L2; restoring correct power usually clears it.

What to check first (fast, safe checks)

  • Reset the dryer by turning it Off, then unplugging it for 1 minute and plugging it back in.
  • Confirm the dryer plug is fully seated and the cord is secure at the terminal block (see the MED5800TW0 owner's manual).
  • Check your home electrical panel for a tripped 2-pole breaker; reset it fully (Off, then On).
  • If you use a wall receptacle adapter or extension cord, remove it; dryers should plug directly into the correct outlet.
  • Run a Timed Dry heated cycle to test heat after power is restored.

What L2 usually looks like in real use

What you notice Most common cause What to do
Drum tumbles but clothes stay cold One leg of 240V is out (L2 missing) Reset breaker; verify outlet power
Dryer stops and shows L2 mid-cycle Intermittent power connection Check cord/terminal connections per manual
No heat and long dry times Low/incorrect supply voltage Confirm proper 240V supply before replacing parts

When to consider parts (only after power is confirmed)

If your outlet and breaker are correct and the dryer still will not heat, then a heating circuit failure is more likely. For MED5800TW0, common heat-related parts include:

Why it matters

Your dryer motor can run on 120 volts, but the heater typically needs full 240-volt power. When L2 is missing, you can get tumbling with no heat, longer dry times, and repeated error codes.

Last updated: February 2026

On the Maytag MED5800TW0 dryer, the most common part failures usually show up as no heat, long dry times, no tumbling, or the dryer stopping mid-cycle. These problems typically trace back to the heating circuit (element and safety fuses), the drum drive system (belt and support parts), or airflow restrictions that cause overheating.

Most common failures and what you notice

  • No heat or weak heat: failed heating element, thermal cut-off, or high-limit thermostat
  • Dryer runs but won’t tumble: broken belt, worn drum support parts, or a motor issue
  • Stops mid-cycle or trips safety devices: restricted venting, overheating, or a failing thermostat
  • Won’t start at all: door switch problem, timer/control issue, or motor problem
  • Long dry times: lint buildup, crushed vent hose, blower wheel issues, or low heat

Model-relevant parts that commonly fix these symptoms

For MED5800TW0, these are frequent repair paths when symptoms match:

Symptom Common suspect part Example part on this model
No heat Heating element Dryer element 279838
Overheats, then shuts down Thermal cut-off or high-limit thermostat Dryer thermal cut-off fuse kit 279816, dryer high-limit thermostat WP3977767
Drum won’t turn Belt or drum support wear Belt 341241, dryer repair kit 4392065
Won’t start Door switch Dryer door switch WP3406107

Quick checks we recommend before replacing parts

  • Clean the lint screen and confirm strong airflow at the outside vent hood
  • Run a timed cycle and compare heat output to sensor cycles (sensor cycles can shut off early when the load reaches the selected dryness)
  • Listen for motor hum with no drum movement (often belt or drum support)
  • Check for a burning smell or very hot cabinet (often airflow restriction or thermostat protection)
  • Review cycle and feature behavior (Cool Down and Wrinkle Prevent use no heat)

Why it matters

Dryer “part failures” are often triggered or made worse by poor airflow. Fixing venting and lint buildup helps prevent repeat failures of heating safety parts and improves drying performance.

For cycle behavior and sensor-dry operation details, use the MED5800TW0 owner's manual.

Last updated: February 2026

You can get replacement parts for your Maytag dryer model MED5800TW0 directly from the parts list for this model, so you can match the exact part to your dryer. Use the model number on your dryer’s ID tag to confirm fit before ordering, and reference the owner's manual for model-specific guidance.

Best way to find the right part for MED5800TW0

  • Start with your full model number: MED5800TW0.
  • Identify the symptom (no heat, won’t start, noisy, not tumbling).
  • Match the part by name and ID, not just by a similar-looking photo.
  • If you are replacing a wear item, consider replacing related wear parts at the same time.
  • Keep your dryer’s cycle and feature info handy (for example, Sensor Dry vs. Timed Dry settings).

Common replacement parts customers order for this dryer

These are examples of parts available for MED5800TW0 that often solve common dryer problems:

Dryer problem Common part to check/replace Example part on this model
Drum not turning Drum belt, motor pulley, drive motor Belt 341241
No heat or weak heat Heating element, thermal cut-off, thermostat Dryer element 279838
Dryer won’t start when door closes Door switch Dryer door switch WP3406107

Why it matters

Ordering by the exact model (MED5800TW0) helps prevent returns and repeat repairs because Maytag dryers can use different belts, thermostats, or controls across similar-looking models. The owner's manual also helps you choose the right cycle and settings, which can reduce overheating and premature part wear.

Last updated: February 2026

Maytag dryer model MED5800TW0 uses “capacity” to mean drum volume (cubic feet), but the drum volume is not listed in the available model documentation excerpt. Use the load-size guidance in the MED5800TW0 owner's manual to match load size to the Sensor Dry and Timed Dry cycles.

What “capacity” means on a dryer

Dryer capacity is the interior drum volume, not the weight of laundry. It affects tumbling action, airflow, and how well the moisture-sensing system can detect dryness.

  • Drum volume is measured in cubic feet (cu. ft.)
  • Larger loads need space to tumble for even drying
  • Overloading restricts airflow and increases dry time
  • Underloading can cause uneven results on some sensor cycles

Practical load-size guidance for MED5800TW0

These targets work well for most Maytag dryers of this design.

  • Fill the drum no more than about 3/4 full for mixed loads
  • Dry bulky items (comforters, quilts, mattress pads) one at a time when possible
  • If items come out damp, reduce load size and verify the lint screen is clean
  • If drying takes too long, check venting and consider using Timed Dry to finish

Capacity and cycle choice (quick reference)

Load type Best starting cycle What to watch
Everyday mixed load Sensor Dry Stop when desired dryness is reached
Towels, denim Sensor Dry Avoid packing the drum; allow tumbling
Small loads Timed Dry or lower heat Prevent overdrying
Still damp at end Timed Dry Add time in small increments

Why it matters

Using the right load size helps the dryer heat and airflow work efficiently, reduces cycle time, and lowers wear on moving parts such as the belt 341241.

Last updated: February 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Range
Food Processor
Front-Engine Lawn Tractor
Gas Range
Lawn Edger
Parts
Power Stapler
Radial Arm Saw
Refrigerator
Top-Mount Refrigerator
Wall Oven