Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Goodman CKL60-1 split-system outdoor unit

Goodman CKL60-1 split-system outdoor unit Parts

Here are the diagrams and repair parts for Goodman CKL60-1 split-system outdoor unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for CKL60-1 Split-System Outdoor Unit

  • Cover for Goodman CKL60-1 - Part 1787624PDG

    Cover & control box diagram

    Cover

    In Stock
    $52.66
    Minus Item
    Qty
    Plus Item
  • Bottom Pan for Goodman CKL60-1 - Part 1787212PDG

    Compressor & tubing diagram

    Bottom Pan

    In Stock
    $100.68
    Minus Item
    Qty
    Plus Item
  • Panel for Goodman CKL60-1 - Part 1787709PDG

    Cover & control box diagram

    Panel

    In Stock
    $54.26
    Minus Item
    Qty
    Plus Item
  • Contactor for Goodman CKL60-1 - Part CONT3P025024VS

    Cover & control box diagram

  • Goodman Condenfanmotor 1/4hp,1sp,6pl for Goodman CKL60-1 - Part 0131M00847S

    Top & panels diagram

    Motor

    Part #0131M00007PS

    Replaced by #0131M00847S

    Info Icon
    Manufacturer substitution
    This part replaces 0131M00007PS. Substitute parts can look different from the original.
    In Stock
    $308.03
    Minus Item
    Qty
    Plus Item
  • Louvered Panel-return Side for Goodman CKL60-1 - Part 1259565PDG

    Top & panels diagram

    Louvered Panel-return Side

    Part #1259565PDG

    The manufacturer no longer makes this part, and there's no substitute part

  • Pvc Conduit 11.0 Lrg for Goodman CKL60-1 - Part 17788000062

    Cover & control box diagram

    Pvc Conduit 11.0 Lrg

    Part #17788000062

    The manufacturer no longer makes this part, and there's no substitute part

  • Start Assist for Goodman CKL60-1 - Part B1141657

    Cover & control box diagram

    Start Assist

    Part #B1141657

    The manufacturer no longer makes this part, and there's no substitute part

  • Central Air Conditioner Condenser Top Cover for Goodman CKL60-1 - Part 1779415PDG

    Top & panels diagram

    Central Air Conditioner Condenser Top Cover

    Part #1779415PDG

    The manufacturer no longer makes this part, and there's no substitute part

  • Compressor for Goodman CKL60-1 - Part ZR57K3PFV930

    Compressor & tubing diagram

    Compressor

    Part #ZR57K3PFV930

    The manufacturer no longer makes this part, and there's no substitute part

Goodman Split-System Outdoor Unit CKL60-1 FAQs

For Goodman model CKL60-1, the “60” in the model number typically indicates about 60,000 BTU/h of cooling capacity; divide by 12,000 to estimate 5 tons. Confirm the exact capacity on the unit data plate and in the owner's manual.

Quick tonnage math (works for most central AC model numbers)

Look for a 2-digit number in the model number that matches common BTU “thousands” sizes.

  • Find the capacity code: 18, 24, 30, 36, 42, 48, 60
  • Treat it as BTU in thousands (example: 36 = 36,000 BTU/h)
  • Divide by 12 to convert BTU “thousands” to tons
  • If the model number does not include a clear code, use the rating label on the outdoor unit

Common capacity codes and tonnage

Model number code Approx. BTU/h Approx. tons
18 18,000 1.5
24 24,000 2
36 36,000 3
48 48,000 4
60 60,000 5

Why the model number method is only an estimate

Manufacturers sometimes reuse numbers for a “series” or round capacities, and actual rated output can vary by match-up (outdoor unit + indoor coil) and efficiency configuration.

Best ways to confirm tonnage

  • Check the outdoor unit nameplate for BTU/h or capacity
  • Cross-check the model number details in the owner's manual
  • If you are replacing electrical parts during diagnosis (for example, a weak run capacitor), match parts by model and wiring diagram; the capacitor CAP050600440RTP listed for CKL60-1 is a common service item for condenser fan and compressor circuits

Why it matters

Correct tonnage helps you choose compatible replacement parts, verify the right indoor coil match, and avoid performance issues like short cycling, poor humidity control, or high energy use.

Last updated: February 2026

A Goodman central AC outdoor unit like model CKL60-1 typically lasts 12 to 15 years. With correct sizing, solid installation, and consistent maintenance (clean coils, correct airflow, and healthy electrical components), it commonly reaches the upper end of that range.

Typical lifespan ranges (what to expect)

Most split-system outdoor units fall into these practical ranges:

Condition Typical lifespan What usually limits life
Normal use + basic maintenance 12 to 15 years Wear on compressor, fan motor, electrical parts
Excellent maintenance + mild conditions 15 to 20 years Corrosion, refrigerant leaks, compressor fatigue
Neglected maintenance or harsh conditions 8 to 12 years Overheating, dirty coils, electrical failures

What shortens the life of an outdoor AC unit

These are the most common lifespan killers we see on outdoor condensers:

  • Dirty condenser coil causing high head pressure and overheating
  • Restricted airflow from debris, weeds, or blocked coil fins
  • Low refrigerant charge from leaks (runs hotter and longer)
  • Electrical stress from weak capacitors, pitted contactors, or loose wiring
  • Oversized or undersized system (short-cycling or constant run time)
  • Salt air, fertilizer, or sprinkler overspray accelerating corrosion

Maintenance that adds years

Use this checklist as a simple longevity plan:

  • Keep 18 to 24 inches of clearance around the unit; remove leaves and grass clippings
  • Rinse the outdoor coil gently (power off first); straighten crushed fins carefully
  • Replace or clean the indoor air filter regularly to protect airflow and coil temperature
  • Have refrigerant charge, superheat/subcooling, and electrical readings checked annually
  • If the unit struggles to start or the fan hums, test the run capacitor and replace if weak (a common fix is the capacitor CAP050600440RTP)

Why it matters

Once an outdoor unit gets into the 12 to 15 year range, small issues (dirty coils, weak capacitor, low charge) can turn into expensive stress on the compressor. Preventive maintenance and timely part replacement usually cost far less than running the system in an overheated or hard-start condition.

For model-specific maintenance intervals and safety steps, follow the owner's manual.

Last updated: February 2026

For the Goodman CKL60-1 split-system outdoor unit, the most common problems are no cooling, the outdoor fan or compressor not starting, breaker trips, and reduced airflow from a dirty coil. Many of these issues trace back to power, airflow, or a weak run capacitor; use the owner's manual for model-specific checks.

Common CKL60-1 symptoms and likely causes

  • Outdoor unit will not start: tripped breaker, blown disconnect fuse, failed contactor, weak capacitor
  • Hums but will not run: weak capacitor, stuck fan motor, compressor hard-start issue
  • Runs but does not cool well: dirty condenser coil, restricted airflow, low refrigerant charge (sealed system)
  • Short cycling: dirty coil, overheating, electrical control issue
  • Breaker trips: shorted wiring, failing compressor, failing fan motor, capacitor failure

Quick checks we recommend first (safe, homeowner-level)

  • Set thermostat to cool and lower setpoint 3 to 5 degrees.
  • Confirm the outdoor disconnect is fully inserted and the breaker is on.
  • Inspect and replace the indoor air filter (a clogged filter can make the outdoor unit struggle).
  • Gently clean debris from the outdoor coil and keep 18 to 24 inches of clearance.
  • Listen for clicking at the outdoor unit (often indicates a call for cooling but a start problem).

Capacitor problems (very common on outdoor units)

A weak capacitor is one of the most frequent causes of a condenser fan or compressor that will not start or that starts slowly and overheats. If testing confirms a bad capacitor, match it exactly to the CKL60-1 parts listing, such as the capacitor CAP050600440RTP.

Symptom What it often points to Typical next step
Fan blade not spinning, unit hums Weak capacitor or bad fan motor Test capacitor; inspect fan motor
Compressor tries to start then stops Weak capacitor or compressor issue Test capacitor; technician diagnosis
Breaker trips on start Electrical short or failing motor/compressor Inspect wiring; technician service

Why it matters

Running the CKL60-1 with poor airflow or a failing electrical start component can overheat the compressor and increase energy use. Catching coil, filter, and capacitor issues early helps prevent bigger repairs.

Last updated: March 2026

Most common symptoms to help you fix your ranges

Choose a symptom to see related range repairs.

Main causes: power supply failure, blown thermal fuse, bad relay control board, damaged terminal block, wiring failure…

Main causes: broken broiler element, weak or broken broil burner igniter, control system failure, faulty temperature sen…

Main causes: power supply problem, control thermostat or electronic control board failure, broken element, bad burner ig…

Main causes: broken oven door lock assembly, wiring failure, electronic control board problem…

Main causes: faulty temperature sensor, electronic control board problem, control thermostat failure, weak burner ignite…

Main causes: bad bake element, broken burner igniter, control system failure, blown thermal fuse, faulty temperature sen…

Main causes: food splatters, spilling food on the oven door, allowing liquid to drip through oven door vent when cleanin…

Most common repair guides to help fix your ranges

These step-by-step repair guides will help you safely fix what’s broken on your range.

How to replace a range oven door switch

How to replace a range oven door switch

The oven door switch detects whether the oven door is closed and helps control the oven light. Replace the switch if it …

Repair time and Difficulty

 30 minutes or less
How to replace a range oven door lock assembly

How to replace a range oven door lock assembly

Oven door not locking? You can replace the lock assembly in less than 30 minutes. Here's how.…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your ranges

Use the advice and tips in these articles and videos to get the most out of your range.

4 things you're doing wrong with your oven

4 things you're doing wrong with your oven

You might be surprised by these 4 tips for using your oven better.…

How to correct an oven's temperature setting

How to correct an oven's temperature setting

If your oven consistently undercooks or overcooks, it might need recalibration. You can reset it yourself.…

Quiz: Are you abusing your appliances?

Quiz: Are you abusing your appliances?

Take our quiz to see how well you treat your appliances. Then, find out what you can do to help them last longer.…

Parts & More

Bottom-Mount Refrigerator
Chipper/Shredder
Downdraft Ventilation System
Dryer
Electric Range
Electric Wall Oven
Gas Grill
Gas Walk-Behind Mower
Laundry Center
Parts
Range
Range Hood
Vacuum Cleaner
Washer