Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Kenmore 153320592HT power miser 12 electric water heater

Kenmore 153320592HT power miser 12 electric water heater Parts

Here are the diagrams and repair parts for Kenmore 153320592HT power miser 12 electric water heater, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 153320592HT Water Heaters

  • Relief Valve for Kenmore 153320592HT - Part 9001583

    Water heater diagram

    Relief Valve

    Part #9001583

    The manufacturer no longer makes this part, and there's no substitute part

  • Water Heater Buss Bar Kit for Kenmore 153320592HT - Part 9001591

    Water heater diagram

    Water Heater Buss Bar Kit

    Part #9001591

    The manufacturer no longer makes this part, and there's no substitute part

  • Terminal Cover for Kenmore 153320592HT - Part 9002303

    Terminal Cover

    Part #9002303

    The manufacturer no longer makes this part, and there's no substitute part

  • Rating Plate for Kenmore 153320592HT - Part 0270182

    Water heater diagram

    Rating Plate

    Part #0270182

    The manufacturer no longer makes this part, and there's no substitute part

  • Lower Panel for Kenmore 153320592HT - Part 9001587

    Water heater diagram

    Lower Panel

    Part #9001587

    The manufacturer no longer makes this part, and there's no substitute part

  • Dip Tube for Kenmore 153320592HT - Part 9002432

    Water heater diagram

    Dip Tube

    Part #9002432

    The manufacturer no longer makes this part, and there's no substitute part

  • Heat Trap Nipple (cold Inlet) (153.320392, 153.320393) for Kenmore 153320592HT - Part 9002420

    Water heater diagram

    Heat Trap Nipple (cold Inlet) (153.320392, 153.320393)

    Part #9002420

    The manufacturer no longer makes this part, and there's no substitute part

  • Water Heater Owner's Manual for Kenmore 153320592HT - Part 0002917680

    #NI

    All parts diagram

    Water Heater Owner's Manual

    Part #0002917680

    The manufacturer no longer makes this part, and there's no substitute part

Kenmore Power Miser 12 Electric Water Heater 153320592HT FAQs

For Kenmore model 153320592HT, a typical professional heating element replacement runs about $150 to $350 per element (parts plus labor). DIY cost is usually the price of the element plus a new gasket, but the total depends on whether your heater is set up for a 3800W or 5500W element (the rating plate “If Converted” box). See the 153320592HT owner's manual for the correct element selection and safe service steps.

Typical cost breakdown
  • DIY parts only: commonly $70 to $200+ (element plus gasket, depending on which element you need)
  • Professional replacement (one element): commonly $150 to $350
  • Professional replacement (both elements): commonly $250 to $600
  • Possible add-ons: thermostat replacement, wiring repair, or sediment flush
Scenario What you usually pay What drives the price
DIY replace one element Parts cost only Correct wattage/voltage match, gasket, tools
Pro replace one element $150 to $350 Labor rates, access, condition of fittings
Pro replace both elements $250 to $600 Time on site, additional diagnostics
Picking the right element for this model

This Kenmore Power Miser 12 series uses 240V elements; the manual notes ordering depends on whether the heater was converted.

Why it matters

Using the correct element rating helps prevent nuisance tripping, slow recovery, and repeat failures. The manual also warns to never energize the heater unless the tank is completely full of water, because a dry-fired element can fail immediately.

Last updated: January 2026

Kenmore model 153320592HT is built for one voltage only, and you must match your home’s supply to the voltage shown on the water heater’s rating plate. In this Power Miser 12 series, the heating elements are designed to run at their rated wattage on 240V systems.

How to tell which voltage your water heater uses

Use the rating plate near the bottom access panel as the deciding factor.

  • Turn OFF power at the breaker before opening any access panel
  • Check the rating plate for the listed voltage (commonly 240V on full-size electric tanks)
  • Confirm the breaker size and wire gauge match the heater requirements
  • Never connect the heater to a different voltage than listed
  • If you are converting the lower element wattage, confirm the supply is 240V first

For model-specific safety and electrical details, follow the 153320592HT owner's manual.

120V vs 240V: what changes in real use

Most residential electric tank water heaters are 240V because they recover (reheat) hot water faster.

Voltage Typical use case What you notice most
120V Point-of-use or very small tanks Slower recovery, lower power draw
240V Standard residential tank heaters Faster recovery, supports higher watt elements
What the manual says about this Kenmore Power Miser 12 series

This series is equipped for one voltage only, and the upper element (on double-element models) operates at its rated wattage on 240 volts. The lower element can be configured to operate at 3800W or converted to 5500W on a 240V system (when the installation supports it).

Why it matters

Using the wrong voltage can cause no-heat symptoms, nuisance breaker trips, damaged components (like the thermostat or heating element), and unsafe operation. Matching the rating plate protects the heater and keeps hot water recovery consistent.

Last updated: January 2026

For the Kenmore 153320592HT electric water heater, the three most important parts are the dip tube (brings cold water into the tank), the anode rod (protects the tank from corrosion), and the temperature-pressure relief valve (helps prevent dangerous pressure buildup). For locations and service steps, use the 153320592HT owner's manual.

What each part does
  • Dip tube: Directs incoming cold water to the bottom of the tank so hot water at the top stays hot.
  • Anode rod: Sacrifices itself to slow rusting inside the tank; this helps extend tank life.
  • Temperature-pressure relief valve (T&P valve): Opens if temperature or pressure gets too high; the manual notes it can relieve excess pressure from thermal expansion, but it is not meant to discharge constantly.
Quick symptoms checklist
  • Dip tube problem: Lukewarm water quickly, reduced hot-water volume.
  • Anode rod worn out: Rusty odor, discolored water, faster tank corrosion.
  • T&P valve issue: Dripping or discharge (especially after heating cycles), or a valve that will not open when tested by a pro.
Related parts you may replace on this model

If you are troubleshooting hot-water performance or leaks, these model-listed parts often come up:

Part What it affects Common reason to replace
Water heater dip tube 100108708 Hot-water delivery Cracked or deteriorated tube
Anode rod 100108660 Tank protection Rod depleted from corrosion
Relief valve 100108779 Safety pressure relief Leaking, sticking, or age
Why it matters

These three components protect hot-water performance, tank longevity, and system safety. For example, a closed plumbing system can build pressure as water heats (thermal expansion); the T&P valve may open to relieve pressure, but the long-term fix is addressing the cause (such as adding an expansion tank when needed).

Last updated: January 2026

For Kenmore model 153320592HT, the wire size and conductor count depend on how the heater is configured and how your utility feeds it. The manual calls out 10 AWG copper with 30-amp overcurrent protection for 240V, higher-wattage operation; use 10/2 with ground for a standard 2-wire 240V feed, and 10/3 with ground only for a 3-wire (time clock or off-peak meter) setup. Confirm your exact connection type in the 153320592HT owner's manual.

What the manual says for this model

The 153320592HT documentation includes both 2-wire and 3-wire connection diagrams and specifies wiring and breaker sizing when configured for higher wattage.

  • 240V supply required; match the rating plate voltage
  • 10 AWG copper (60°C) is specified for 30-amp loading in the higher-wattage configuration
  • Two-wire connection is the most common household hookup
  • Three-wire connection is used with a utility time clock or off-peak meter
  • For long runs (about over 90 ft), wire sizing can change per electrical code
10/2 vs 10/3: which one to buy

Both are 10-gauge cable; the difference is the extra insulated conductor in 10/3.

Cable What you get (typical) Use it when What happens to the extra wire
10/2 w/ground 2 insulated conductors + ground Standard 240V, 2-wire feed None (no extra conductor)
10/3 w/ground 3 insulated conductors + ground Off-peak or time-clock, 3-wire feed Used as the third conductor required by that system
Quick safety and install checks
  • Turn off power at the breaker before opening the junction box
  • Verify the heater voltage and wiring diagram before pulling cable
  • Use a dedicated circuit sized to the heater configuration
  • Tighten junction box connections securely; overheating starts at loose terminals
Why it matters

Choosing the correct cable prevents overheated connections and nuisance breaker trips, and it ensures the thermostats and heating elements in the 153320592HT operate on the intended 240V circuit.

Last updated: January 2026

Most common symptoms to help you fix your water heaters

Choose a symptom to see related water heater repairs.

Main causes: faulty pressure relief valve, water is overheating…

Main causes: thermostats need adjustment, water heater capacity too low, bad heating element, thermostat failure, excess…

Main causes: broken heating element, thermostat failure, excessive tank sediment, tank size too small, burner valve asse…

Main causes: thermostat temperature set too high, thermostats need adjustment, faulty thermostat, shorted heating elemen…

Main causes: loose water pipe fittings, leaky drain valve, bad temperature-pressure relief valve, leaky heating element,…

Main causes: lack of power, no gas supply, thermostat limit switch tripped, bad element, bad thermostat, gas valve failu…

Main causes: water supply needs chlorine treatment, anode rod too reactive…

Repair guides for electric water heaters

How to replace a water heater element

How to replace a water heater element

If your water heater runs out of hot water quickly and one of the two heating elements has failed, replace the element f…

Repair time and Difficulty

 30 minutes or less
How to replace a water heater temperature and pressure (T&P) relief valve

How to replace a water heater temperature and pressure (T&P) relief valve

Replace a broken temperature/pressure (T&P) relief valve on an electric water heater using these instructions.…

Repair time and Difficulty

 15 minutes or less
How to replace a water heater drain valve

How to replace a water heater drain valve

If the drain valve on your electric water heater is leaking water, replace it following these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your water heaters

Use the advice and tips in these articles and videos to get the most out of your water heater.

Quiz: Are you abusing your appliances?

Quiz: Are you abusing your appliances?

Take our quiz to see how well you treat your appliances. Then, find out what you can do to help them last longer.…

Water heater common questions

Water heater common questions

These common questions and answers can help you make the most of your water heater.…

Easy DIY water heater repairs

Easy DIY water heater repairs

Read about some water heater repairs that you can easily do yourself.…

Parts & More

Bottom-Mount Refrigerator
Carpet Cleaner
Cooktop
Dishwasher
Dryer
Electric Range
Front-Engine Lawn Tractor
Heating & Cooling Combined Unit
Parts
Power Rake
Receiver
Reciprocating Saw
Walk-Behind Mower
Wall Oven
Washer