Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Kenmore 11071262311 gas dryer

Kenmore 11071262311 gas dryer Parts

Here are the diagrams and repair parts for Kenmore 11071262311 gas dryer, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 11071262311 Gas Dryer

  • Whirlpool Dryer Drum Support Roller Shaft for Kenmore 11071262311 - Part WPW10359270

    Bulkhead parts diagram

    Dryer Drum Support Roller Shaft

    Part #W10359270

    Replaced by #WPW10359270

    Info Icon
    Manufacturer substitution
    This part replaces W10359270. Substitute parts can look different from the original.
    In Stock
    $45.49
    12% OFF Phone Price : $51.49Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Valve Coil Kit for Kenmore 11071262311 - Part WPW10328463

    W10336852 burner assembly parts diagram

    Dryer Gas Valve Coil Kit

    Part #W10328463

    Replaced by #WPW10328463

    Info Icon
    Manufacturer substitution
    This part replaces W10328463. Substitute parts can look different from the original.
    In Stock
    $70.22
    8% OFF Phone Price : $76.22Info Icon
    Minus Item
    Qty
    Plus Item
  • Whirlpool Dryer Drum Front Bearing for Kenmore 11071262311 - Part W11035878

    Cabinet parts diagram

    Dryer Drum Front Bearing

    Part #W10568603

    Replaced by #W11035878

    Info Icon
    Manufacturer substitution
    This part replaces W10568603. Substitute parts can look different from the original.
    In Stock
    $58.92
    9% OFF Phone Price : $64.92Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Lint Chute Seal for Kenmore 11071262311 - Part W11415783

    Bulkhead parts diagram

    Dryer Lint Chute Seal

    Part #347139

    Replaced by #W11415783

    Info Icon
    Manufacturer substitution
    This part replaces 347139. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $14.84
    12% OFF Phone Price : $16.84Info Icon
    Minus Item
    Qty
    Plus Item
  • Laundry Appliance Control Knob Clip for Kenmore 11071262311 - Part WP8536939

    Top and console parts diagram

    Laundry Appliance Control Knob Clip

    Part #8536939

    Replaced by #WP8536939

    Info Icon
    Manufacturer substitution
    This part replaces 8536939. Substitute parts can look different from the original.
    In Stock
    $8.15
    11% OFF Phone Price : $9.15Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Door Seal for Kenmore 11071262311 - Part W10389572

    Cabinet parts diagram

    Dryer Door Seal

    Part #W10389572

    The manufacturer no longer makes this part, and there's no substitute part

  • Dryer Front Panel Clip for Kenmore 11071262311 - Part W10854425

    Cabinet parts diagram

    Dryer Front Panel Clip

    Part #3394083

    Replaced by #W10854425

    Info Icon
    Manufacturer substitution
    This part replaces 3394083. Substitute parts can look different from the original.
    In Stock
    $12.80
    14% OFF Phone Price : $14.80Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Drum Assembly for Kenmore 11071262311 - Part W10899578

    Bulkhead parts diagram

    Dryer Drum

    Part #W10389436

    Replaced by #W10899578

    Info Icon
    Manufacturer substitution
    This part replaces W10389436. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $188.89
    6% OFF Phone Price : $200.89Info Icon
    Minus Item
    Qty
    Plus Item
  • Dryer Burner And Gas Valve Assembly for Kenmore 11071262311 - Part W10823508

    Gas Burner

    Part #W10336852

    Replaced by #W10823508

    Info Icon
    Manufacturer substitution
    This part replaces W10336852. Substitute parts can look different from the original.
    In Stock
    $265.67
    $12.00 OFF Phone Price : $277.67Info Icon
    Minus Item
    Qty
    Plus Item
  • Appliance Spray Paint (white) for Kenmore 11071262311 - Part 350930

    Optional parts (not included) diagram

    Appliance Spray Paint (white)

    Part #350930
    This item is not returnable
    In Stock
    $26.00
    19% OFF Phone Price : $32.00Info Icon
    Minus Item
    Qty
    Plus Item

Kenmore Gas Dryer 11071262311 FAQs

No. The Kenmore gas dryer model 11071262311 plugs into a standard 120-volt, 60 Hz, grounded 3-prong outlet on a dedicated 15- or 20-amp circuit; it does not use the 240-volt outlet that most electric dryers require. See the electrical requirements in the installation guide.

What outlet and circuit we recommend
  • Use a grounded 3-prong (120V) receptacle.
  • Put the dryer on a separate 15- or 20-amp circuit (time-delay fuse or circuit breaker recommended).
  • Keep the outlet within about 2 ft. of either side of the dryer (typical placement guidance).
  • Do not use an extension cord.
  • Do not use an adapter or remove the ground prong.
Quick comparison: gas vs. electric dryer power
Dryer type Typical plug/outlet Typical circuit Notes
Gas dryer (11071262311) 120V grounded 3-prong 15 or 20 amp Electricity runs the motor, controls, and igniter; gas provides heat
Electric dryer 240V dryer outlet 30 amp Electricity provides heat and runs the motor/controls
Why it matters

Using the correct grounded outlet and a dedicated circuit helps prevent nuisance tripping, reduces the risk of electrical shock, and keeps the dryer controls and motor running reliably during heating and tumbling.

Last updated: February 2026

For Kenmore gas dryer model 11071262311, a typical hookup includes a grounded 3-prong (120V) outlet, a gas supply line with an easy-to-reach manual shutoff valve, a flexible gas connector to the dryer’s gas pipe, and a vent duct routed to the home’s exhaust. See the installation guide for the exact connection layout and safety steps.

What you should see behind the dryer
  • A manual gas shutoff valve on the home’s gas supply line (handle parallel to the pipe when open)
  • A 1/2-inch NPT gas supply line feeding the shutoff valve
  • A 3/8-inch flexible gas connector running from the shutoff valve area to the dryer
  • A grounded 3-prong electrical outlet (120 Volt, 60 Hz, 15 or 20 amp)
  • A vent connection attached to the dryer exhaust outlet (avoid crushing or kinking)
Common connection methods (gas line)

The installation instructions describe two typical ways to connect the dryer to the gas supply.

Method What it uses When it’s commonly used
Option 1 (recommended) New flexible stainless steel gas connector plus flare/NPT fittings Most standard installations where local codes allow
Option 2 (alternate) Approved aluminum or copper tubing with proper adapters Some existing setups; tubing length and gas type affect what’s allowed
Key safety and setup checks
  • Plug into a grounded 3-prong outlet; do not use an adapter or extension cord.
  • Keep the shutoff valve within about 6 feet of the dryer and easy to access.
  • After connecting gas fittings, open the shutoff valve and test joints with an approved noncorrosive leak-detection solution (bubbles indicate a leak).
  • Move the dryer into place carefully; avoid crushing or kinking the vent.
Why it matters

A correct hookup helps your 11071262311 dryer heat safely and vent properly. Poor venting can cause long dry times and overheating, and incorrect gas connections can create leaks that must be corrected before operating the dryer.

Last updated: February 2026

To reset your Kenmore gas dryer model 11071262311, we recommend a hard reset: turn the dryer off, unplug it (or switch the breaker off) for about 1 to 5 minutes, then restore power and try a cycle again. This clears many temporary control and sensor glitches.

Quick reset steps (safe and effective)
  • Turn the cycle selector to Off.
  • Unplug the dryer (or turn the circuit breaker Off).
  • Wait 1 to 5 minutes.
  • Restore power.
  • Close the door fully and press Start.
  • If the dryer still will not start, follow the checks in the 11071262311 installation guide.
If it still will not start after a reset

The installation checklist for this model points to a few basics that commonly stop a dryer from running:

  • Confirm the dryer is plugged into a grounded 3-prong outlet.
  • Check the house fuse/breaker (not tripped, fuse intact and tight).
  • Make sure the door is fully closed.
  • Verify the exhaust vent is not crushed or kinked.
  • If the dryer runs but you do not feel heat after a few minutes, confirm the gas shut-off valve is open.
Part to check if the dryer thinks the door is open

If the dryer has power but will not run when you press Start, a failed door switch is a common cause on many Kenmore dryers.

Symptom What it often points to Example part for this model
Drum light works but dryer will not start Door switch not closing electrically Dryer door switch WP3406107
No response at all Power supply issue, breaker, cord/outlet Use the checklist in the 11071262311 installation guide
Why it matters

Resetting clears minor electronic lockups, but it will not bypass a real safety condition. On gas dryers, airflow restrictions, an open door switch circuit, or a closed gas valve can prevent normal operation and should be corrected before repeated restarts.

Last updated: February 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Audio Equipment
Bottom-Mount Refrigerator
Compact Refrigerator
Dishwasher
Dryer
Gas Pressure Washer
Gas Walk-Behind Mower
Microwave
Parts
Rear-Tine Tiller
Reciprocating Saw
Room Air Conditioner