Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Kenmore 72163659300 microwave/hood combo

Kenmore 72163659300 microwave/hood combo Parts

Here are the diagrams and repair parts for Kenmore 72163659300 microwave/hood combo, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 72163659300 Microwave/Hood Combo

  • Vent Grille for Kenmore 72163659300 - Part 3530W0A041B

    Oven cavity diagram

    Vent Grille

    Part #3530W0A041B

    The manufacturer no longer makes this part, and there's no substitute part

  • Microwave/hood Glass for Kenmore 72163659300 - Part 4890W1A030X

    Door diagram

    Microwave/hood Glass

    Part #4890W1A030X

    The manufacturer no longer makes this part, and there's no substitute part

  • Microwave/hood Cover for Kenmore 72163659300 - Part 3550W1S001A

    Interior 1 diagram

    Microwave/hood Cover

    Part #3550W1S001A

    The manufacturer no longer makes this part, and there's no substitute part

  • Bracket, C for Kenmore 72163659300 - Part 4810W1P009A

    Control panel diagram

    Bracket, C

    Part #4810W1P009A

    The manufacturer no longer makes this part, and there's no substitute part

  • Microwave/hood Control Panel for Kenmore 72163659300 - Part 3720W0C168B

    Control panel diagram

    Microwave/hood Control Panel

    Part #3720W0C168B

    The manufacturer no longer makes this part, and there's no substitute part

  • Harness for Kenmore 72163659300 - Part 6877W1A349B

    Interior 2 diagram

    Harness

    Part #6877W1A349B

    The manufacturer no longer makes this part, and there's no substitute part

  • Tray for Kenmore 72163659300 - Part 3390W1A023B

    Oven cavity diagram

    Tray

    Part #3390W1A023B

    The manufacturer no longer makes this part, and there's no substitute part

  • Mount for Kenmore 72163659300 - Part 4960W1A004A

    Oven cavity diagram

    Mount

    Part #4960W1A004A

    The manufacturer no longer makes this part, and there's no substitute part

  • Shelf for Kenmore 72163659300 - Part 5026W1A053C

    Oven cavity diagram

    Shelf

    Part #5026W1A053C

    The manufacturer no longer makes this part, and there's no substitute part

  • Fuse for Kenmore 72163659300 - Part 3B72974C

    Interior 2 diagram

    Fuse

    Part #3B72974C

    The manufacturer no longer makes this part, and there's no substitute part

Kenmore Microwave/Hood Combo 72163659300 FAQs

To remove a Kenmore over-the-range microwave like model 72163659300, we take the weight off the mounting bracket by supporting the unit from below, remove the upper cabinet mounting bolts, then tilt the front down and lift the microwave off the rear wall bracket. Follow the exact bolt locations and venting setup in the installation guide.

Before you start (safety and prep)

  • Turn off power at the breaker, then unplug the microwave if the cord is accessible.
  • Protect the cooktop with a thick towel or cardboard.
  • Use two people; these units are heavy and awkward.
  • If the unit is vented (roof or wall), plan to disconnect the duct as you lower it.
  • Keep a container for screws and the upper cabinet bolts.

Removal steps (typical over-the-range process)

  1. Support the microwave from below (a helper holding it, or a stable support platform).
  2. Remove the vent grille (front top grille) screws and pull the grille off.
  3. Disconnect wiring as needed (unplug cord from the upper cabinet outlet; do not pull on the cord).
  4. From inside the upper cabinet, remove the mounting bolts that go down into the top of the microwave.
  5. Tilt the front of the microwave downward slowly while a helper supports the weight.
  6. If ducted, separate the duct connection as the unit lowers.
  7. Lift the microwave up and off the rear wall mounting bracket, then carry it away.

What changes the steps (venting type)

Your 72163659300 can be set up for different venting paths; that affects what you disconnect during removal.

Venting setup What you usually disconnect during removal What to watch for
Room-vented (recirculating) No ductwork Charcoal filter and grille area clearance
Wall-vented Rear duct transition Sharp sheet metal edges, damper alignment
Roof-vented Upper duct transition Cabinet cutout alignment and duct screws

Why it matters

The upper cabinet bolts and rear wall bracket carry nearly all the load. Supporting the microwave and removing bolts in the right order prevents cabinet damage, bent brackets, and dropped units.

Last updated: February 2026

Yes. On many Kenmore microwave/hood combo models like 72163659300, the practical “reset” is a power reset: cancel the current program, then restore power to clear a control glitch. If the oven still will not run, the issue is usually power, door latching, or a failed safety component.

Quick reset steps (safe, no tools)

  • Touch STOP/Clear to cancel any active cooking or timer.
  • If the display is frozen or unresponsive, unplug the microwave (or switch the breaker off).
  • Wait 1 minute, then restore power.
  • Re-set the clock if needed.
  • Test with a simple heat test (1 cup of water for 1 minute).

For model-specific control features (clock, child lock, audible signals), use the owner's manual.

If it still will not start after a reset

The troubleshooting guidance for this Kenmore series points to a few common causes when “nothing works” or the microwave “will not run”:

  • Power cord not fully plugged into a grounded outlet
  • House fuse blown or circuit breaker tripped
  • Door not firmly closed and latched
  • START not pressed after entering a cook time
  • A previous operation is still programmed (use STOP/Clear)

What to check first

Symptom Most likely cause What we recommend
No display, no lights No power to unit Check outlet, breaker, and cord seating
Display works, won’t run Door not latching or control not cleared Press STOP/Clear, close door firmly, try again
Runs but no heat High-voltage circuit problem Use our heating diagnosis steps below

Why it matters

A “reset” clears stuck keypad inputs and cancels programmed cycles, but it will not fix a failed door interlock or high-voltage heating component. Doing the quick checks first prevents unnecessary parts replacement.

Parts that commonly relate to “won’t run” or “no heat”

If basic checks do not solve it, these model-compatible parts are often involved:

For a step-by-step heating diagnosis, use why is my microwave not heating.

Last updated: February 2026

The average lifespan of a Kenmore microwave/hood combo like model 72163659300 is about 8 to 10 years with normal use and basic maintenance (keeping vents and filters clean, avoiding slamming the door, and fixing small issues early). See the owner's manual for care and operating guidance.

What affects lifespan most

  • Grease buildup restricting airflow and overheating the magnetron area
  • Running the microwave empty or repeatedly overheating foods
  • Door wear that prevents proper latching (can stop heating or starting)
  • Power surges and frequent breaker trips
  • Heavy daily use (multiple long cook cycles per day)

Maintenance that helps it last longer

  • Clean the grease filters regularly; replace charcoal filtration when airflow or odors worsen (recirculating setups)
  • Keep the intake and exhaust vents clear; confirm the damper moves freely
  • Use microwave-safe cookware and avoid metal trim that can arc
  • Close the door gently to protect the latch and interlock system
  • Replace failed lights promptly so you can monitor cooking safely

Common “wear” items vs. “major” items

Type Examples What you typically notice
Wear/maintenance Charcoal filter, lamps, door latch pieces Odors, dim/no light, door not closing smoothly
Functional/safety Door interlock switches, thermostats Won’t start, stops mid-cycle, intermittent operation
High-voltage heating Capacitor, diode Runs but does not heat, loud hum, burning smell

Why it matters

Microwave/hood combos rely on airflow for cooling; restricted ventilation and door-latch wear are two of the biggest reasons heating components fail early. Staying ahead of filter cleaning and door issues helps you reach the full 8 to 10 year service life.

Last updated: March 2026

Symptoms for gas ranges

Main causes: gas supply problem, faulty pressure regulator, clogs in burner or orifice, control system failure, faulty t…

Main causes: burner igniter switch failure, bad spark module, dirty or damaged spark electrode, wiring failure…

Repair guides for gas ranges

How to replace a gas range oven igniter

How to replace a gas range oven igniter

If your gas oven doesn't heat up, the problem could be a faulty oven igniter. These step-by-step instructions guide you …

Repair time and Difficulty

 45 minutes or less
How to replace an oven temperature sensor on a gas range

How to replace an oven temperature sensor on a gas range

See how to replace an oven temperature sensor on a gas range.…

Repair time and Difficulty

 15 minutes or less
How to replace a gas range oven control board

How to replace a gas range oven control board

These step-by-step instructions explain how to replace an oven control board on a gas range…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your microwave/hood combos

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Range
Electric Water Heater
Freestanding Ice Maker
Front-Engine Lawn Tractor
Gas Range
Parts
Side-By-Side Refrigerator
Top-Mount Refrigerator
Washer