Browse Parts for A42-15 Air Handler with Coil

  • Blower Mount for Goodman A42-15 - Part 17171-04

    Air handler diagram

    Blower Mount

    Part #17171-04

    The manufacturer no longer makes this part, and there's no substitute part

  • Terminal Blo for Goodman A42-15 - Part B13682-48

    Air handler diagram

    Terminal Blo

    Part #B13682-48

    The manufacturer no longer makes this part, and there's no substitute part

  • Lwr Accs Pnl for Goodman A42-15 - Part 17220-51P

    Air handler diagram

    Lwr Accs Pnl

    Part #17220-51P

    The manufacturer no longer makes this part, and there's no substitute part

  • Service Coil for Goodman A42-15 - Part 1585404-42NS

    Air handler diagram

    Service Coil

    Part #1585404-42NS

    The manufacturer no longer makes this part, and there's no substitute part

  • Heating Elem for Goodman A42-15 - Part B10374-69

    Air handler diagram

    Heating Elem

    Part #B10374-69

    The manufacturer no longer makes this part, and there's no substitute part

  • Central Air Conditioner Air Handler Blower Motor for Goodman A42-15 - Part B13400-353

    Air handler diagram

    Central Air Conditioner Air Handler Blower Motor

    Part #B13400-353

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel, Upper Access ((a36-05) (a36-06) (a36-08) (a36-10) (a42-10) for Goodman A42-15 - Part 17220-06P

    Air handler diagram

    Panel, Upper Access ((a36-05) (a36-06) (a36-08) (a36-10) (a42-10)

    Part #17220-06P

    The manufacturer no longer makes this part, and there's no substitute part

  • Heating Elem for Goodman A42-15 - Part B10374-72

    Air handler diagram

    Heating Elem

    Part #B10374-72

    The manufacturer no longer makes this part, and there's no substitute part

  • Circuit Breaker for Goodman A42-15 - Part 14952-04

    Air handler diagram

    Circuit Breaker

    Part #14952-04

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Temperature Limit Switch for Goodman A42-15 - Part B13701-15

    Air handler diagram

    Furnace Temperature Limit Switch

    Part #B13701-15

    The manufacturer no longer makes this part, and there's no substitute part

Goodman Air Handler with Coil A42-15 FAQs

Most Goodman air handlers like model A42-15 typically last 10 to 15 years. With consistent maintenance (clean airflow, correct electrical operation, and prompt repair of worn components), it’s common to reach the upper end of that range and sometimes longer.

Typical lifespan and what affects it

A Goodman air handler’s service life depends more on operating conditions than the brand name alone.

  • Run time and climate: long heating and cooling seasons shorten life
  • Airflow health: dirty filters and blocked returns overheat the blower motor and heater
  • Moisture and corrosion: coil-area condensation can accelerate rust and electrical issues
  • Electrical stability: loose connections and weak capacitors stress the motor
  • Repair history: replacing failing wear parts early prevents bigger damage

What “end of life” usually looks like

These are the most common failure patterns we see in air handlers with coils:

Symptom Common cause Typical fix
Blower hums but won’t start Weak run capacitor Replace capacitor 7. 12907
No or weak airflow Worn blower wheel or failing motor Inspect wheel, test motor; replace if needed
Heat strips do not heat Failed heating element or sequencer/control issue Test elements and controls; replace failed part
Loud vibration or scraping Damaged blower wheel or debris Clean housing; replace wheel if bent

Maintenance that extends air handler life

We recommend these practical steps to keep your A42-15 running longer:

  • Change or clean the air filter on schedule (most homes: every 1 to 3 months)
  • Keep return vents and supply registers open and unobstructed
  • Vacuum dust from the blower compartment during seasonal service (power off)
  • Have a technician check electrical connections and heater operation annually
  • Address early warning signs (burning smell, repeated breaker trips, slow-start blower)

Why it matters

Air handlers fail gradually; catching a weak capacitor, noisy blower wheel, or overheating heater early can prevent a blower motor failure and reduce comfort problems, energy use, and downtime.

Last updated: February 2026

Replacing a blower motor in a Goodman system typically costs about $300 to $900 total (parts plus labor), depending on motor type (PSC vs ECM), accessibility, and whether the technician also replaces related items like a run capacitor. For the Goodman A42-15 air handler, the blower motor itself is a major share of that total.

Typical cost breakdown (what you usually pay for)

Costs vary by region and job complexity, but this is a practical way to think about the total:

Cost item Typical range Notes
Blower motor part $150 to $600 ECM motors usually cost more than PSC motors
Labor $150 to $400 Often 1 to 3 hours depending on access and wiring
Diagnostic/service call $75 to $150 Sometimes credited toward the repair
Optional add-ons $10 to $150 Capacitor, wiring repair, wheel cleaning, etc.

Model-specific parts to check for the A42-15

If your A42-15 uses the listed motor, the part price is a strong indicator of the parts portion of the repair:

When the motor is not the real problem

Before replacing the motor, we typically see these issues cause “no blower” or “weak airflow” symptoms:

  • Failed run capacitor (motor hums, starts slowly, or needs a push)
  • Dirty blower wheel or heavy dust buildup restricting airflow
  • Loose/burned wiring connections or a failing control signal
  • Overheating from a clogged filter or blocked return air
  • Heat kit or sequencer issues on electric heat systems (blower timing problems)

A quick electrical check with a meter can prevent replacing the wrong part; our how to use a multimeter to test electrical parts video is a good starting point.

Why it matters

A failing blower motor can reduce airflow across the coil, which hurts comfort and efficiency and can lead to overheating or icing issues. Catching the root cause early often keeps the repair closer to the low end of the cost range.

Last updated: February 2026

An air handler (including the Goodman A42-15 air handler with coil) is the indoor unit that moves conditioned air through your ductwork. Most air handlers include a blower assembly, an evaporator coil, electrical controls, and often electric heat components, plus a drain system to manage condensation.

Main parts you will typically find

  • Blower motor and blower wheel: pushes air across the coil and into the ducts
  • Evaporator (cooling) coil: absorbs heat during cooling; can also support heat pump operation
  • Electric heat kit components (if equipped): heating elements and safety controls
  • Run capacitor: helps the blower motor start and run efficiently
  • Sequencer/relays and wiring: controls when electric heat stages turn on
  • Condensate drain pan and drain line: collects and routes away water from the coil
  • Air filter rack or filter grille: holds the filter that protects the coil and blower

Model-relevant examples of parts we list for Goodman A42-15

If you are troubleshooting airflow, no-heat, or a blower that will not start, these are common service parts for this model:

Quick “symptom to part area” guide

Symptom Most likely area to check Common part types
Weak airflow Blower section Motor, blower wheel, filter
Blower hums but will not start Motor electrical Capacitor, motor
No heat (electric heat) Heat kit section Heating element, sequencer
Water around unit Drain system Drain pan/line, coil icing causes

Why it matters

Knowing the major air handler components helps you troubleshoot faster and order the right replacement part the first time. For example, airflow problems usually point to the blower motor, blower wheel, or a restricted filter, while electric heat issues often involve heating elements and their controls.

Last updated: February 2026

A 2-ton Goodman air handler height depends on the exact model and cabinet width, so there is no single “standard” height. For your Goodman A42-15 air handler with coil, confirm the cabinet dimensions on the unit data label, then match that to your closet or plenum clearance.

Typical height range you can plan around

Most 2-ton, multi-position air handlers (including many Goodman-style cabinets) are commonly in the 40 to 55 inch overall height range, depending on whether the coil is integrated, the cabinet width, and the blower section design.

Use this as a planning range, then verify your exact unit:

  • Check the data plate on the air handler cabinet (often inside the blower door or on the exterior panel)
  • Look for overall height and cabinet width
  • Measure from the bottom rail to the top of the cabinet (exclude field-installed transitions unless you need total installed height)

How to measure your A42-15 correctly

To avoid ordering the wrong plenum, stand, or return drop, measure these points:

  • Cabinet height: bottom of cabinet to top of cabinet
  • Installed height: cabinet height plus any field-installed base, filter rack, or transition
  • Clearance: space needed to remove the blower door and slide out the blower assembly
  • Drain and refrigerant line space: room for condensate trap, drain slope, and line set bends

Quick reference table (what you are measuring)

Measurement What it includes Why you need it
Cabinet height Factory cabinet only Fit in closet, match coil section
Installed height Cabinet plus base/stand/transition Total floor-to-duct clearance
Service clearance Space in front/side Access blower, wiring, and heater kit

Why it matters

Air handler height affects duct alignment, condensate drainage, and service access. Even a 1 to 2 inch mismatch can force duct rework or make it hard to remove the blower or electric heat components later.

Parts that often come up during air handler service

If you are servicing the blower or electric heat while verifying fitment, these model-matched parts are commonly involved:

Last updated: February 2026

Goodman air handler width depends on the exact model and cabinet size. For the Goodman A42-15 air handler with coil, the most reliable way to confirm width is to match the cabinet dimensions to the model’s data label and then compare to the correct replacement parts listed for this unit, such as the blower components.

Typical width range (what most homeowners see)

Most residential Goodman air handlers are commonly built in cabinet widths around:

  • 14 inches (compact cabinets)
  • 17.5 inches (mid-size cabinets)
  • 21 inches (larger cabinets)
  • 24.5 inches (wide cabinets)

If you are measuring for a closet, platform, or return plenum, measure the metal cabinet, not the coil lineset, drain fittings, or electrical whip.

How to measure width the right way

Use a tape measure and follow these steps:

  • Turn off power at the breaker to avoid contact with live wiring
  • Measure left-to-right across the front face of the cabinet
  • Measure at the widest point of the sheet metal, not the door lip
  • Ignore protruding items (refrigerant lines, condensate drain, wiring)
  • If installed tight to framing, measure the opening and subtract clearance

Quick reference: width vs. what it affects

What you are doing Why width matters What to check
Replacing the air handler Fit in closet or attic access Cabinet width and service clearance
Replacing blower parts Correct airflow and fit Blower wheel diameter and motor mounting
Rebuilding electric heat Heater kit fit and wiring Heater element size and sequencer style

Parts that help confirm you have the right unit

When you are confirming the correct air handler, matching parts to model A42-15 helps prevent ordering the wrong cabinet size. Common air-handler parts on this model include:

Why it matters

Air handler width drives fit, duct transitions, filter rack alignment, and service access. A cabinet that is even 1 to 2 inches wider than expected can prevent installation or force ductwork changes.

Last updated: February 2026

Repair guides for side-by-side refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a press-in door gasket in a side-by-side refrigerator

How to replace a press-in door gasket in a side-by-side refrigerator

The door gasket seals the gap around the door to keep the cold air in and the warm air out. Replace a worn or damaged do…

Repair time and Difficulty

 15 minutes or less
How to replace an ice maker in a side-by-side refrigerator

How to replace an ice maker in a side-by-side refrigerator

Learn how to replace the ice maker in a side-by-side refrigerator with these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your air handlers

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Range
Freestanding Freezer
Front-Engine Lawn Tractor
Gas Walk-Behind Mower
Home Improvement
Lawn Sweeper
Microwave/Hood Combo
Parts
Range
Range Hood
Refrigerator
Side-By-Side Refrigerator
Water Softener