Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

GE DDC0580BAL dryer Parts

Here are the diagrams and repair parts for GE DDC0580BAL dryer, as well as links to manuals and error code tables, if available.

GE DDC0580BAL dryer
By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for DDC0580BAL Dryer

  • Toe Board for GE DDC0580BAL - Part WE20X347

    #402

    All parts diagram

    Toe Board

    Part #WE20X347

    The manufacturer no longer makes this part, and there's no substitute part

  • Hinge Bushing for GE DDC0580BAL - Part WE1X404

    #609

    All parts diagram

    Hinge Bushing

    Part #WE1X404

    The manufacturer no longer makes this part, and there's no substitute part

  • Weld Asm Cab Front Cf for GE DDC0580BAL - Part WE20X565

    #NI

    All parts diagram

    Weld Asm Cab Front Cf

    Part #WE20X565

    The manufacturer no longer makes this part, and there's no substitute part

  • Clip for GE DDC0580BAL - Part WE1X299

    #500

    All parts diagram

    Clip

    Part #WE1X299

    The manufacturer no longer makes this part, and there's no substitute part

  • 846b133g031a for GE DDC0580BAL - Part WE10X262

    #395

    All parts diagram

    846b133g031a

    Part #WE10X262

    The manufacturer no longer makes this part, and there's no substitute part

  • Base & Wrapper Asm Cf for GE DDC0580BAL - Part WE20X595

    #NI

    All parts diagram

    Base & Wrapper Asm Cf

    Part #WE20X595

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw, 2-pack for GE DDC0580BAL - Part WZ4X236

    #233

    All parts diagram

    Screw, 2-pack

    Part #WZ4X236

    The manufacturer no longer makes this part, and there's no substitute part

  • Hsng&nut A for GE DDC0580BAL - Part WH46X211

    #72

    All parts diagram

    Hsng&nut A

    Part #WH46X211

    The manufacturer no longer makes this part, and there's no substitute part

  • Thermostat Cover for GE DDC0580BAL - Part WE1X944

    #305

    All parts diagram

    Thermostat Cover

    Part #WE1X944

    The manufacturer no longer makes this part, and there's no substitute part

  • Button Plug for GE DDC0580BAL - Part WE1X983

    #11

    All parts diagram

    Button Plug

    Part #WE1X983

    The manufacturer no longer makes this part, and there's no substitute part

GE Dryer DDC0580BAL FAQs

For a GE dryer model DDC0580BAL, the most reliable way to know the correct belt size is to match the belt to your exact model using the parts list; measuring works, but small differences in length or rib/profile can cause slipping or a no-tumble problem.

Best way: match the belt to your model

We recommend identifying the belt by model first, then using measurements only as a backup.

  • Find the belt listing for GE DDC0580BAL in the model’s parts breakdown
  • Compare the belt style (flat vs V-belt, ribbed vs smooth)
  • Confirm the belt’s length and width from the listing before ordering
  • If your dryer has been repaired before, verify the belt style matches the current drum and motor setup

If you need to measure the belt (backup method)

If the belt is missing, broken, or the part listing is unavailable, measure the belt path and belt profile.

  • String method (belt path circumference): route a string around the drum and motor pulley path where the belt rides, pull snug, mark and measure
  • Belt width: measure across the belt (flat belts are commonly around 1/4 inch wide, but variations matter)
  • Belt thickness/profile: note whether it is flat, multi-rib, or V-belt style
  • Condition check: a stretched, glazed, or cracked belt can measure “right” but still be wrong for performance

Quick measurement checklist

What to measure What it tells you Common mistake
Circumference (string method) Overall belt length needed Measuring loosely and ordering too long
Width Correct belt tracking on drum/pulleys Ignoring width and getting a belt that walks off
Profile (flat/rib/V) Correct grip and pulley fit Ordering a flat belt for a ribbed pulley

Why it matters

A belt that is even slightly off can cause squealing, thumping, poor tumbling, or the motor running without the drum turning. Correct belt fit also reduces wear on the motor and drum support components.

When the dryer is open, we typically inspect airflow and drive-area components for noise or drag.

  • Drum support and bearing surfaces
  • Blower wheel area for rubbing or wobble
  • Motor mounting hardware and straps

If you’re chasing a rumbling or vibration issue along with a belt problem, inspect the blower wheel and retainer: dryer blower wheel WE16X16 and dryer blower wheel retainer assembly WE1X688.

Last updated: January 2026

The most common issues we see with the GE DDC0580BAL dryer are no-start or weak tumbling (drive or motor problems), loud squealing or rumbling (bearing or blower issues), and long dry times (airflow restrictions). Many symptoms trace back to the motor, blower wheel, or worn support components.

Most common symptoms and what they usually mean

  • Dryer will not start: power supply issue, door switch/timer circuit, or a failing drive motor
  • Hums but will not tumble: motor struggling, seized blower, or mechanical drag in the drum support system
  • Loud squeal or grind: worn bearing surfaces or support hardware (often gets worse quickly)
  • Rattling or thumping: loose fasteners, clip/bracket issues, or a damaged blower wheel
  • Long dry times or overheating: clogged lint screen/venting, restricted blower housing, or weak airflow

Parts that commonly relate to these problems

If your DDC0580BAL is noisy, not tumbling, or airflow seems weak, these model-matched parts are often involved:

Symptom Common area to inspect Example part on this model
No tumble, burning smell, intermittent run Drive motor and mounting Motor WE17X10010
Loud roaring, vibration, poor airflow Blower wheel and retainer Dryer blower wheel WE16X16 and dryer blower wheel retainer assembly WE1X688
Squeal/rumble from drum area Drum support/bearing surfaces Bearing plate WE1X461

Quick checks we recommend before replacing parts

  • Clean the lint screen and confirm strong airflow at the outside vent hood
  • Inspect the vent duct for crushing, kinks, or heavy lint buildup
  • Run a short timed cycle and listen: squeal (bearing), roar (blower), hum (motor)
  • Unplug the dryer and spin the drum by hand; it should turn smoothly without scraping
  • Check for loose screws or brackets that can rattle during operation

Why it matters

Airflow restrictions and failing rotating parts (motor, blower wheel, bearing surfaces) can turn a simple “takes too long to dry” complaint into overheating, shutdowns, or additional wear. Catching noise and airflow symptoms early helps prevent bigger repairs.

For error-code style troubleshooting on GE dryers, use GE cleanspeak dryer error codes.

Last updated: March 2026

On a GE dryer such as model DDC0580BAL, an E5 display is a fault code from the electronic control. The exact definition varies by GE platform, so we treat E5 as a “stop and check” code and troubleshoot by symptoms (won’t start, stops mid-cycle, poor drying).

What to do right away

  • Unplug the dryer (or switch off the breaker) for 2 minutes to reset the control.
  • Clean the lint screen and confirm strong airflow at the outside vent hood.
  • Try a small load on a timed cycle to see if the code returns.
  • Listen at start-up for a hum, click, or immediate shutoff.
  • If the drum is hard to turn by hand, stop using the dryer and check for binding.

Symptom-based troubleshooting for E5

Because E5 meanings differ across GE series, use what the dryer is doing to narrow the cause.

What you notice Most common area to check What it can indicate
Hums but drum will not turn Drive system, blower area Jammed blower wheel, failing motor, seized drum support
Starts then stops quickly Motor circuit, wiring, control sensing Loose connection, overheating motor, intermittent motor
Runs but dries slowly Venting, airflow, blower Clogged vent, restricted airflow, damaged blower wheel

Parts that commonly match E5-type symptoms on DDC0580BAL

If your DDC0580BAL is humming, stalling, or shutting down, these model-matched parts are often involved:

Why it matters

An E5 code usually appears when the dryer detects abnormal operation. Addressing airflow restrictions and any motor or blower binding prevents repeat shutdowns, long dry times, and extra wear on rotating parts.

For GE-specific code families, compare symptoms to GE’s platform guides such as GE gfd model series error codes or GE cleanspeak dryer error codes.

Last updated: January 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Band Saw
Bottom-Mount Refrigerator
Dryer
Elliptical Machine
Front-Engine Lawn Tractor
Gas Line Trimmer
Grass Catcher Attachment
Household Fan
Parts
Rolling Tool Cart
Table Saw