Here are the diagrams and repair parts for Maytag UKI1000AXX ice maker kit, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for UKI1000AXX Refrigerators

  • Refrigerator Water Tubing for Maytag UKI1000AXX - Part WPB5705307

    Ice maker kit diagram

    Tubing Valve

    Part #67579-6

    Replaced by #WPB5705307

    Info Icon
    Manufacturer substitution
    This part replaces 67579-6. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $11.94
    14% OFF Phone Price : $13.94Info Icon
    Minus Item
    Qty
    Plus Item
  • Refrigerator Water Tubing Clip for Maytag UKI1000AXX - Part WPM0114003

    Ice maker kit diagram

    Refrigerator Clamp Spring

    Part #60333-4

    Replaced by #WPM0114003

    Info Icon
    Manufacturer substitution
    This part replaces 60333-4. Substitute parts can look different from the original.
    In Stock
    $8.98
    10% OFF Phone Price : $9.98Info Icon
    Minus Item
    Qty
    Plus Item
  • Nut for Maytag UKI1000AXX - Part WP245183

    Ice maker kit diagram

    Refrigerator Nut

    Part #69432-1

    Replaced by #WP245183

    Info Icon
    Manufacturer substitution
    This part replaces 69432-1. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $33.29
    Minus Item
    Qty
    Plus Item
  • Aluminum Cement for Maytag UKI1000AXX - Part 95093-1

    Ice maker kit diagram

    Aluminum Cement

    Part #95093-1

    The manufacturer no longer makes this part, and there's no substitute part

  • Refrigerator Wire Harness for Maytag UKI1000AXX - Part 61001882

    Ice maker kit diagram

    Refrigerator Wire Harness

    Part #61001882

    The manufacturer no longer makes this part, and there's no substitute part

  • Refrigerator Water Valve for Maytag UKI1000AXX - Part 61003020

    Ice maker kit diagram

    Refrigerator Water Valve

    Part #61003020

    The manufacturer no longer makes this part, and there's no substitute part

  • Refrigerator Wire Harness for Maytag UKI1000AXX - Part 61003573

    Ice maker kit diagram

    Refrigerator Wire Harness

    Part #61003573

    The manufacturer no longer makes this part, and there's no substitute part

  • Refrigerator Water Line for Maytag UKI1000AXX - Part 61001858

    Ice maker kit diagram

    Refrigerator Water Line

    Part #61001858

    The manufacturer no longer makes this part, and there's no substitute part

  • Refrigerator Bracket Module for Maytag UKI1000AXX - Part 95107-1

    Ice maker kit diagram

    Refrigerator Bracket Module

    Part #95107-1

    The manufacturer no longer makes this part, and there's no substitute part

  • Ice Module for Maytag UKI1000AXX - Part 06100049

    Ice maker kit diagram

    Ice Module

    Part #06100049

    The manufacturer no longer makes this part, and there's no substitute part

Maytag Ice Maker Kit UKI1000AXX FAQs

On the Maytag UKI1000AXX ice maker kit, water fill is typically adjusted at the ice maker module using the small fill-adjustment screw. Turn the screw clockwise in small increments to reduce water fill; turn it counterclockwise to increase water fill.

Before you adjust anything

  • Unplug the refrigerator or switch off power at the breaker.
  • Locate the ice maker head (the front cover usually snaps off).
  • Find the fill-adjustment screw (often labeled “+ / -” or “increase / decrease”).
  • Make only small changes; a little turn makes a noticeable difference.
  • Restore power and let the ice maker run several cycles before judging results.

How much to turn the screw

Most ice makers respond well to small, repeatable adjustments.

Adjustment Direction Typical change When to use it
Decrease fill Clockwise 1/4 turn Cubes are fused together, hollow “shell” cubes, water sloshes in mold
Increase fill Counterclockwise 1/4 turn Small cubes, incomplete cubes, cubes look thin
Re-check After 2 to 3 harvests N/A Confirms the change without overcorrecting

If adjusting does not fix the problem

Water fill issues are often caused by water supply restrictions or a weak inlet valve, not the adjustment screw.

Why it matters

Correct water fill prevents hollow cubes, clumping, overflow into the ice bin, and slow ice production. A properly set fill level also reduces strain on the inlet valve and helps the ice maker harvest consistently.

Last updated: January 2026

For the Maytag UKI1000AXX ice maker kit, no-water filling is usually caused by a shutoff water supply, a kinked or frozen fill tube, or a failed inlet valve that is not opening to send water to the ice maker. Start with the supply and tubing checks, then test the valve and ice maker components.

Quick checks we recommend first

  • Confirm the household shutoff valve is fully open.
  • Check the water line for kinks, pinches, or a crushed section behind the refrigerator.
  • Look for a frozen fill tube at the back of the ice maker (ice blockage stops filling).
  • Make sure the freezer is cold enough; most ice makers need about 0 F to 10 F to cycle reliably.
  • If you recently moved the refrigerator, recheck the line connection for leaks or restrictions.

Parts that commonly cause “no water to ice maker”

If the supply is good and the fill tube is not frozen, the next most common failure is the inlet valve.

Symptom Most likely cause What to do next
No water sound at all during fill Inlet valve not opening Test/replace refrigerator water valve WP61005273
Fill tube keeps freezing Seeping inlet valve or low airflow Replace valve; clear ice; verify freezer temp
Ice maker cycles but stays dry Valve, fill cup, or module issue Inspect refrigerator ice maker fill cup WP628356 and module
Intermittent fill Weak valve coil or wiring issue Check connections; test valve coil resistance

How to troubleshoot safely (basic DIY)

  • Unplug the refrigerator before inspecting wiring or removing the ice maker.
  • Thaw a frozen fill tube with warm air (hair dryer on low) and clear any ice blockage.
  • If the tube refreezes within a day or two, replace the inlet valve because it often seeps and refreezes.
  • If you have a multimeter, check the valve coil for continuity and inspect harness connections for corrosion.

For electrical testing help, use how to use a multimeter to test electrical parts video.

Why it matters

When the ice maker cannot fill, it will stop producing ice and can also lead to repeated cycling, small cubes, or a frozen fill tube. Fixing the water supply restriction or replacing the inlet valve restores normal fill volume and protects the ice maker module.

Last updated: January 2026

For a Maytag UKI1000AXX ice maker kit, we replace the ice machine water filter about every 6 months in most homes. Replace it sooner if ice production slows, cubes get smaller or hollow, or you notice taste or odor changes.

Typical replacement schedule

Most ice maker and refrigerator water filtration setups follow one of these intervals:

  • Every 6 months (most common)
  • Around 2,000 gallons of water filtered (if your system tracks usage)
  • Immediately after long periods of non-use (vacation) if water tastes stale
  • Sooner with hard water, heavy ice use, or noticeable sediment

Signs your filter needs changing

A filter can clog gradually, which reduces water flow to the ice maker. Watch for:

  • Smaller cubes or hollow cubes
  • Slow ice production or no ice
  • Cloudy ice or black specks (carbon fines) in the first batches after a change
  • Off taste or odor in ice
  • Water leaks at the filter head or connections

Quick troubleshooting if ice is slow after a filter change

If ice production drops right after installing a new filter, these checks usually help:

  • Flush several batches of ice (or run water through the system if applicable)
  • Confirm the filter is fully seated and locked
  • Check the supply shutoff valve is fully open
  • Inspect the inlet valve and tubing for restrictions; the refrigerator water valve WP61005273 is a common flow-control part in many Maytag and Whirlpool-built systems

Filter timing at a glance

Household situation Replace about every
Average use, normal water quality 6 months
Heavy ice use (large family, entertaining) 3 to 6 months
Hard water or sediment 2 to 4 months
Seasonal/vacation home At start of season

Why it matters

A fresh filter helps maintain steady water flow to the ice maker, supports normal cube size, and reduces taste and odor issues. It also helps protect water system components from sediment buildup.

Last updated: January 2026

On the Maytag UKI1000AXX ice maker kit, the water filter is typically not built into the ice maker itself. In most installations, filtration is either handled by the refrigerator’s main water filter (if equipped) or by an inline filter installed in the water supply line behind the refrigerator.

Most common filter locations to check

  • Inside the fresh food compartment (often upper right area) behind a small cover
  • In the base grille or kick plate at the bottom front of the refrigerator
  • Inline on the 1/4-inch water line behind the refrigerator (a small cylinder or cartridge housing)
  • Under-sink inline filter feeding the refrigerator water line

Quick way to identify what you have

Use this checklist before buying a replacement:

  • If you see a twist-in cartridge inside the refrigerator, that is the filter
  • If there is no cartridge inside, pull the refrigerator forward and look for an inline filter on the tubing
  • If the ice maker fills slowly or makes hollow cubes, suspect a restricted filter or water valve
  • If you recently installed the kit, confirm the water line routing and connections at the valve

Parts that affect water flow to the ice maker

If there is no separate filter, low ice production is often caused by the inlet valve or a restriction in the line.

Symptom Common cause What to check next
No water entering ice maker Inlet valve not opening Test/inspect refrigerator water valve WP61005273
Slow fill, small cubes Restricted filter or low pressure Replace filter (if present), verify shutoff valve fully open
Leaks at connections Loose tubing or clamp Inspect fittings, clamp, and tubing routing

Why it matters

A clogged or incorrectly located filter reduces water flow; that leads to slow ice production, small cubes, and can make the ice maker cycle inconsistently. Verifying the filter location first prevents ordering the wrong part.

Last updated: January 2026

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Automotive
Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Leaf Blower
Gas Pressure Washer
Grass Catcher Attachment
Microwave/Hood Combo
Parts
Receiver
Upright Freezer
Washer
Weight System