Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Carrier 38BRC060 SERIES360 condensing unit

Carrier 38BRC060 SERIES360 condensing unit Parts

Here are the diagrams and repair parts for Carrier 38BRC060 SERIES360 condensing unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 38BRC060 SERIES360 Condensing Unit

  • Relay for Carrier 38BRC060 SERIES360 - Part P283-9930

    #89

    All parts diagram

    Relay

    Part #P283-9930

    The manufacturer no longer makes this part, and there's no substitute part

  • Switch for Carrier 38BRC060 SERIES360 - Part KAALP0101LPS

    #56

    All parts diagram

    Switch

    Part #KAALP0101LPS

    The manufacturer no longer makes this part, and there's no substitute part

  • Washer Kit for Carrier 38BRC060 SERIES360 - Part 324392-751

    #75B

    All parts diagram

    Washer Kit

    Part #324392-751

    The manufacturer no longer makes this part, and there's no substitute part

  • 099,kit Sound Blkt for Carrier 38BRC060 SERIES360 - Part KSASH2101COP

    #82

    All parts diagram

    099,kit Sound Blkt

    Part #KSASH2101COP

    The manufacturer no longer makes this part, and there's no substitute part

  • Cushion for Carrier 38BRC060 SERIES360 - Part 312251-201

    #43

    All parts diagram

    Cushion

    Part #312251-201

    The manufacturer no longer makes this part, and there's no substitute part

  • Heater for Carrier 38BRC060 SERIES360 - Part P041-4443

    #12B

    All parts diagram

    Heater

    Part #P041-4443

    The manufacturer no longer makes this part, and there's no substitute part

  • Nut for Carrier 38BRC060 SERIES360 - Part DD02CA101

    Nut

    Part #DD02CA101

    The manufacturer no longer makes this part, and there's no substitute part

  • Mtr Mountng for Carrier 38BRC060 SERIES360 - Part 316709-201

    #32

    All parts diagram

    Mtr Mountng

    Part #316709-201

    The manufacturer no longer makes this part, and there's no substitute part

  • 086,adaptr Parts Assy for Carrier 38BRC060 SERIES360 - Part 324330-701

    #74

    All parts diagram

    086,adaptr Parts Assy

    Part #324330-701

    The manufacturer no longer makes this part, and there's no substitute part

  • Outdoor Ambient Sensor for Carrier 38BRC060 SERIES360 - Part TSTATXXSENO1

    #52

    All parts diagram

    Outdoor Ambient Sensor

    Part #TSTATXXSENO1

    The manufacturer no longer makes this part, and there's no substitute part

Carrier Condensing Unit 38BRC060 SERIES360 FAQs

Yes. Carrier is a strong, well-established AC brand, and Carrier systems like the 38BRC060 condensing unit are known for dependable performance when they are correctly installed and maintained. In real-world use, airflow, filter condition, and routine service have as much impact on comfort and reliability as the brand name.

What “good” means for a central AC system

A “good” central air conditioner brand typically delivers consistent cooling, reasonable operating noise, and long service life when the system is matched to the home and maintained.

Key factors that matter most:

  • Correct sizing and installation of the outdoor condensing unit and indoor equipment
  • Clean, properly installed air filter (a clogged filter raises cost and shortens unit life)
  • Unblocked supply and return registers for proper airflow
  • Outdoor unit kept clear of debris and obstructions
  • Periodic professional inspection of electrical connections and coil condition

Maintenance that protects performance (and why it matters)

Carrier’s own guidance emphasizes that restricted airflow and dirty filters reduce efficiency and shorten lifespan. It also calls out keeping the outdoor unit clear and maintaining at least 12 inches of clearance from tall grass, vines, and shrubs. Details and safety warnings are in the 38BRC060 owner's manual.

Most seasonal or every-other-year service visits include:

  • Inspecting and cleaning or replacing air filter(s)
  • Inspecting and cleaning indoor and outdoor coils as needed
  • Checking electrical wiring and connections
  • Verifying secure physical connections of components
  • Running an operational check to confirm proper working condition

Quick “brand vs. system” reality check

What you’re judging What usually drives the outcome What you can control
Reliability Installation quality, airflow, electrical condition Filter changes, keeping the condenser clear, scheduled service
Efficiency Clean coils, correct refrigerant charge, airflow Filter, registers open, outdoor debris removal
Noise Fan motor condition, mounting, airflow restrictions Keep panels secure; replace worn fan components

When a “good brand” still has problems

If your outdoor fan is noisy, not spinning, or the unit overheats and shuts down, the condenser fan system is a common place to start. For this model, a key replacement part is the central air conditioner condenser fan motor HC39GE237.

Last updated: February 2026

For the Carrier 38BRC060 condensing unit, the most common problems are outdoor fan issues, contactor failures, electrical connection problems, and airflow or coil cleanliness issues that reduce cooling. Many symptoms trace back to the condenser fan motor, propeller, or the contactor in the outdoor unit.

Common symptoms you may notice

  • Outdoor unit will not start, but the thermostat is calling for cooling
  • Outdoor fan is not spinning, spins slowly, or is noisy
  • Unit starts and stops rapidly (short cycling)
  • Warm air indoors, weak cooling, or long run times
  • Buzzing or clicking at the outdoor unit

Likely causes (and what to check first)

Turn off power at the disconnect and breaker before inspecting the outdoor unit.

  • Condenser fan problems: worn motor bearings, failed capacitor (if used), or a damaged blade; check the central air conditioner condenser fan motor HC39GE237 and propeller LA01RA027.
  • Contactor problems: pitted or stuck contacts can prevent the compressor and fan from running; inspect the contacter HN52KD020 for burned terminals or a stuck plunger.
  • Loose or damaged wiring: vibration and weather can loosen spade connectors; look for overheated terminals and brittle insulation.
  • Dirty condenser coil or blocked airflow: debris around the unit and a dirty coil raise head pressure and reduce capacity.
  • Refrigerant or compressor-related issues: icing, poor cooling, or loud compressor operation often requires a licensed HVAC technician.

Quick diagnosis guide

Symptom Most common area Typical next step
Fan not spinning Fan motor or propeller Verify blade spins freely; inspect motor wiring
Loud grinding/squeal Fan motor bearings Replace fan motor
Clicking/buzzing, no run Contactor or power supply Check contactor movement and line voltage
Short cycling Electrical/control or airflow Check contactor, coil cleanliness, indoor filter

Why it matters

Catching a failing fan motor or contactor early helps prevent overheating, nuisance shutdowns, and compressor stress, which is the most expensive component in a central air conditioner.

Helpful model-specific reference

Use the wiring diagram, parts breakdown, and electrical specs in the 38BRC060 owner's manual to match terminals and confirm the correct replacement part for your exact configuration.

Last updated: March 2026

Carrier model 38BRC060 is a 5-ton central air conditioner (condensing unit). In Carrier model numbers, “060” typically indicates about 60,000 BTU/hr of cooling capacity; since 1 ton = 12,000 BTU/hr, that equals 5 tons. For model-specific ratings, confirm in the owner's manual.

Quick conversion (BTU to tons)

  • Find the capacity code in the model number (here, 060).
  • Convert to BTU/hr (typically 60,000 BTU/hr).
  • Divide by 12,000 to get nominal tons.
  • Use nominal tons for sizing discussions; use nameplate data for exact performance.
Model code Nominal BTU/hr Nominal tons
060 60,000 5.0

Why tonnage matters for your system

Correct tonnage helps your system cool and dehumidify properly and protects major components like the compressor and condenser fan motor.

Common symptoms of a mismatched size include:

  • Short cycling (turns on and off too often)
  • Poor humidity control
  • Uneven temperatures across rooms
  • Higher energy use
  • Extra wear on electrical parts (contactor, capacitors) and motors

If you are servicing airflow or outdoor-unit operation on a 5-ton condenser, these parts are commonly involved:

When to use the manual vs. the model code

Use this Best for
Model code (060) Quick identification of nominal tonnage
Owner's manual and unit nameplate Exact electrical and performance specifications

Last updated: February 2026

Repair guides for side-by-side refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a press-in door gasket in a side-by-side refrigerator

How to replace a press-in door gasket in a side-by-side refrigerator

The door gasket seals the gap around the door to keep the cold air in and the warm air out. Replace a worn or damaged do…

Repair time and Difficulty

 15 minutes or less
How to replace an ice maker in a side-by-side refrigerator

How to replace an ice maker in a side-by-side refrigerator

Learn how to replace the ice maker in a side-by-side refrigerator with these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your central air conditioners

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Range
Front-Engine Lawn Tractor
Gas Range
Gas Snowblower
Lawn Sweeper
Microwave
Parts
Range
Side-By-Side Refrigerator
Washer