Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
State PR650XODS water heater

State PR650XODS water heater Parts

Here are the diagrams and repair parts for State PR650XODS water heater, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for PR650XODS Water Heaters

  • Dirt Leg Asy for State PR650XODS - Part 181206-001

    Water heater diagram

    Dirt Leg Asy

    Part #181206-001

    The manufacturer no longer makes this part, and there's no substitute part

  • Vent Pipe for State PR650XODS - Part 9001275

    Vent kit diagram

    Vent Pipe

    Part #9001275

    The manufacturer no longer makes this part, and there's no substitute part

  • Door for State PR650XODS - Part 9000695

    Water heater diagram

    Door

    Part #9000695

    The manufacturer no longer makes this part, and there's no substitute part

  • Vent Pipe for State PR650XODS - Part 9001278

    Vent kit diagram

    Vent Pipe

    Part #9001278

    The manufacturer no longer makes this part, and there's no substitute part

  • Door for State PR650XODS - Part 9000696

    Water heater diagram

    Door

    Part #9000696

    The manufacturer no longer makes this part, and there's no substitute part

  • Gasket for State PR650XODS - Part 9000712

    Gasket

    Part #9000712

    The manufacturer no longer makes this part, and there's no substitute part

  • Vent Kit for State PR650XODS - Part 9000687

    Vent kit diagram

    Vent Kit

    Part #9000687

    The manufacturer no longer makes this part, and there's no substitute part

  • Flue Pipe for State PR650XODS - Part 9001285

    Vent kit diagram

    Flue Pipe

    Part #9001285

    The manufacturer no longer makes this part, and there's no substitute part

  • Thermostat Shield for State PR650XODS - Part 185424-000

    Water heater diagram

    Thermostat Shield

    Part #185424-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Burner Orifice Lp. Lht for State PR650XODS - Part 9004005

    Water heater diagram

    Burner Orifice Lp. Lht

    Part #9004005

    The manufacturer no longer makes this part, and there's no substitute part

State Water Heater PR650XODS FAQs

Most tank-style gas water heaters last 8 to 12 years. For a State PR650XODS gas water heater, good maintenance and stable water quality can push life closer to the high end, while heavy use, hard water, and neglected flushing can shorten it.

Typical lifespan and what changes it

  • 8 to 12 years is the normal service life for a standard tank gas water heater.
  • Hard water and sediment buildup can make the burner work harder and reduce efficiency.
  • A worn anode rod speeds up tank corrosion.
  • Poor venting or combustion issues can stress the burner and safety system.
Condition What you may notice What it usually means
Heavy sediment Rumbling or popping sounds Tank needs flushing; efficiency drops
Corrosion starting Rusty or metallic-smelling hot water Anode rod may be depleted
Combustion problems Pilot won’t stay lit, weak burner Ignition or burner components may need service
End-of-life tank Moisture or leaking at the base Tank failure is near or already happening

Signs your PR650XODS is near end of life

  • Water pooling or leaks at the bottom of the tank
  • Rusty hot water or frequent discoloration
  • Banging, popping, or gurgling during heating cycles
  • Inconsistent hot water or recovery getting noticeably slower
  • Pilot or burner issues that keep returning after cleaning and adjustment

Parts that can help extend performance (when the tank is still sound)

If the tank is not leaking, replacing common wear items can restore reliable operation:

Why it matters

Once a tank starts leaking, replacement becomes the practical fix. Catching corrosion early (often with an anode rod) and keeping sediment under control can help you get the full expected lifespan from a gas water heater.

Last updated: February 2026

For a 50-gallon gas water heater like the State PR650XODS, average labor to install typically runs $400 to $1,000. Labor goes up when the installer must modify gas piping, venting, or water lines, or when permits and code upgrades are required.

What usually changes the labor price

Labor is mostly driven by how close the new heater is to a “like-for-like” swap and how much work is needed to meet current plumbing and gas codes.

  • Venting changes (draft hood, flue size, chimney liner, power vent conversion)
  • Gas line work (new shutoff, sediment trap, resizing, leak testing)
  • Water piping updates (new shutoffs, dielectric unions, expansion tank)
  • T and P relief valve discharge piping additions or rework
  • Location and access (tight closet, attic, crawlspace, stairs)
  • Haul-away of the old tank and site cleanup

Typical labor ranges by job complexity

These ranges are common for a 50-gallon atmospheric-vent gas water heater replacement.

Install scenario Typical labor range What it usually includes
Straight swap (same type, easy access) $400 to $700 Disconnect, set tank, reconnect, basic startup checks
Moderate updates $700 to $1,200 Minor venting or piping changes, added safety items
Complex or code-heavy $1,200 to $2,000+ Significant venting or gas work, difficult access, multiple upgrades

Parts that can affect install time on PR650XODS

If the heater is being serviced during install (or the old unit has ignition issues), these parts can be involved:

Why it matters

A low labor quote can look great until venting, gas-line safety items, or the T and P discharge pipe are added. Comparing quotes using the same scope (swap vs. upgrades) helps you avoid surprise add-ons and keeps the installation safe.

Last updated: February 2026

The most common problem we see on gas water heaters like the State PR650XODS is the pilot light going out or not staying lit. In most cases, the root cause is a weak thermocouple signal, a dirty pilot/igniter area, or an airflow issue that prevents a stable flame.

Most common causes (and what to check first)

  • Thermocouple not sensing flame well: loose connection at the gas control, worn thermocouple, or a weak pilot flame.
  • Dirty pilot/igniter: dust or lint can disrupt ignition and flame stability.
  • Restricted combustion air: blocked intake openings, dirty burner area, or a sealed closet without enough makeup air.
  • Burner orifice or burner tube issues: debris can reduce gas flow and cause a weak, unstable flame.
  • Gas supply problems: partially closed shutoff valve or low supply pressure.

Quick troubleshooting steps (safe, no disassembly)

  1. Confirm the gas shutoff valve is fully open.
  2. Watch the pilot while lighting: a healthy pilot flame is steady and should engulf the thermocouple tip.
  3. Check for drafts around the burner access area that could blow the pilot out.
  4. If your control shows a diagnostic light, match the flash pattern to the State gas water heater error codes.

Parts that commonly fix “pilot won’t stay lit” on PR650XODS

Symptom Most likely part area Example part for this model
Pilot lights, then drops out Flame sensing Water heater thermocouple 100108462
Pilot is weak or inconsistent Pilot tubing/assembly Water heater pilot tube assembly 100108370
Burner lights poorly or is lazy Gas metering/burner Ao smith water heater burner orifice 100108672 or water heater burner tube 100108784

Why it matters

A pilot that will not stay lit usually means the heater is not proving flame reliably, so the gas control shuts down for safety. Fixing the flame-sensing and airflow basics restores consistent hot water and helps prevent nuisance shutdowns.

Last updated: February 2026

Plumbers often steer homeowners away from tankless water heaters because the total install cost and complexity can be much higher than a standard tank, performance can drop in hard-water conditions without regular descaling, and hot-water delivery can feel less consistent when multiple fixtures run at once.

The most common reasons plumbers push back

  • Higher installation complexity: Many homes need upgraded gas piping, dedicated electrical, and specific venting.
  • Hard-water sensitivity: Mineral scale can clog the heat exchanger and reduce efficiency and flow if maintenance is skipped.
  • Flow-rate limits: A single unit may struggle when showers, laundry, and a dishwasher run together.
  • “Cold-water sandwich” and delay: You can get a brief temperature swing or a longer wait for hot water at distant fixtures.
  • More maintenance expectations: Annual flushing or descaling is common in many areas.

Tank vs. tankless: quick comparison

Feature Tank water heater (like State PR650XODS) Tankless water heater
Upfront cost Typically lower Typically higher
Hot water for multiple fixtures Often steadier for simultaneous use Can be limited by GPM and temperature rise
Maintenance Periodic tank flushing, anode checks Regular descaling is often needed
Failure impact Usually gradual (recovery slows) Can be sudden (no hot water)

When tankless can still be a good fit

  • Small households with staggered hot-water use
  • Homes with proper gas supply and venting already in place
  • Owners willing to keep up with descaling and inlet filtering

Why it matters

Choosing the wrong style can lead to higher operating headaches: lukewarm showers during peak demand, nuisance shutdowns from scale, or unexpected retrofit costs. If you are maintaining a tank-style unit like the State PR650XODS, keeping key components in good shape often delivers the most predictable hot water.

Last updated: February 2026

Most common symptoms to help you fix your water heaters

Choose a symptom to see related water heater repairs.

Main causes: faulty pressure relief valve, water is overheating…

Main causes: thermostats need adjustment, water heater capacity too low, bad heating element, thermostat failure, excess…

Main causes: broken heating element, thermostat failure, excessive tank sediment, tank size too small, burner valve asse…

Main causes: thermostat temperature set too high, thermostats need adjustment, faulty thermostat, shorted heating elemen…

Main causes: loose water pipe fittings, leaky drain valve, bad temperature-pressure relief valve, leaky heating element,…

Main causes: lack of power, no gas supply, thermostat limit switch tripped, bad element, bad thermostat, gas valve failu…

Main causes: water supply needs chlorine treatment, anode rod too reactive…

Effective articles & videos to help repair your water heaters

Use the advice and tips in these articles and videos to get the most out of your water heater.

Quiz: Are you abusing your appliances?

Quiz: Are you abusing your appliances?

Take our quiz to see how well you treat your appliances. Then, find out what you can do to help them last longer.…

Water heater common questions

Water heater common questions

These common questions and answers can help you make the most of your water heater.…

Easy DIY water heater repairs

Easy DIY water heater repairs

Read about some water heater repairs that you can easily do yourself.…

Parts & More

Audio Equipment
Carpet Cleaner
Dishwasher
Dryer
Front-Engine Lawn Tractor
Gas Snowblower
Gas Walk-Behind Mower
Laundry Center
Parts
Pressure Cooker
Sewing Machine
Side-By-Side Refrigerator
Television
Washer