Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Williams 25GV-5 LPG wall furnace

Williams 25GV-5 LPG wall furnace Parts

Here are the diagrams and repair parts for Williams 25GV-5 LPG wall furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 25GV-5 LPG Wall Furnace

  • Door for Williams 25GV-5 LPG - Part 8300989

    #1A

    All parts diagram

    Door

    Part #8300989

    The manufacturer no longer makes this part, and there's no substitute part

  • Wire for Williams 25GV-5 LPG - Part P321520

    #36

    All parts diagram

    Wire

    Part #P321520

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Temperature Limit Switch for Williams 25GV-5 LPG - Part P321127

    #33

    All parts diagram

    Furnace Temperature Limit Switch

    Part #P321127

    The manufacturer no longer makes this part, and there's no substitute part

  • Wire for Williams 25GV-5 LPG - Part P321519

    #35

    All parts diagram

    Wire

    Part #P321519

    The manufacturer no longer makes this part, and there's no substitute part

  • Valve for Williams 25GV-5 LPG - Part P172100

    #15D

    All parts diagram

    Valve

    Part #P172100

    The manufacturer no longer makes this part, and there's no substitute part

  • Valve for Williams 25GV-5 LPG - Part P172200

    #15E

    All parts diagram

    Valve

    Part #P172200

    The manufacturer no longer makes this part, and there's no substitute part

  • Wire for Williams 25GV-5 LPG - Part P321518

    #34

    All parts diagram

    Wire

    Part #P321518

    The manufacturer no longer makes this part, and there's no substitute part

  • Valve for Williams 25GV-5 LPG - Part P173200

    #15F

    All parts diagram

    Valve

    Part #P173200

    The manufacturer no longer makes this part, and there's no substitute part

  • Header for Williams 25GV-5 LPG - Part 8300992

    #8

    All parts diagram

    Header

    Part #8300992

    The manufacturer no longer makes this part, and there's no substitute part

  • Gas Valve for Williams 25GV-5 LPG - Part P295001A

    #15C

    All parts diagram

    Gas Valve

    Part #P295001A

    The manufacturer no longer makes this part, and there's no substitute part

Williams Wall Furnace 25GV-5 LPG FAQs

For a Williams 25GV-5 LPG wall furnace, we recommend having a qualified technician handle the installation. Mounting the cabinet can be DIY, but gas piping, combustion air, venting, and any electrical connections must be set up correctly to prevent fire, gas leaks, and carbon monoxide hazards.

What you can safely do yourself

If you are comfortable with basic hand tools, these steps are typically reasonable for a homeowner:

  • Confirm the heater is the correct fuel type (LPG/propane) for your home
  • Measure the wall cavity and verify clearances to combustibles (drywall, studs, insulation)
  • Prepare the mounting location (framing, patching, and securing the unit to studs)
  • Clean the area and keep the burner compartment free of dust and debris
  • Gather tools and supplies before the installer arrives (screwdrivers, level, drill, flashlight)

What should be left to a pro (and why)

These steps directly affect safe combustion and leak-free operation:

  • Connecting and leak-testing the gas line and shutoff valve
  • Setting manifold pressure and verifying proper burner flame
  • Verifying venting and draft (if your setup uses venting)
  • Checking for carbon monoxide risk and confirming safe operation
  • Confirming the installation meets local code requirements and permit rules

Quick decision guide

Task DIY-friendly? Why it matters
Mounting the heater body Usually Prevents vibration, noise, and shifting
Gas connection and leak test No Prevents fire and explosion risk
Venting and combustion setup No Prevents carbon monoxide and poor heating
Final startup and adjustments No Prevents soot, odor, and unsafe flames

Why it matters

Wall furnaces burn fuel inside your living space. Small installation errors (gas leaks, incorrect air supply, poor venting, wrong pressure) can create serious safety hazards and performance problems like soot buildup, strong odors, or nuisance shutdowns.

Helpful DIY reading before you start

Use our safety overview in are diy appliance repairs safe to decide which steps you should do yourself versus hand off to a technician.

Last updated: February 2026

To relight a Williams wall heater such as model 25GV-5, we turn the gas control knob to PILOT, press and hold it in while lighting the pilot, then keep holding briefly so the thermocouple heats up before switching back to ON.

Before we relight (safety and setup)

  • Set the thermostat to the lowest setting.
  • Turn the gas control knob to OFF and wait at least 5 minutes to clear any unburned gas.
  • Make sure the area around the wall furnace is clear and well ventilated.
  • Locate the pilot access or observation opening (some units have a small pilot observation door).
  • Have a long match or long-reach lighter ready.

Relighting steps (typical Williams standing-pilot sequence)

  1. Turn the gas control knob to PILOT.
  2. Press and hold the knob in (this opens gas to the pilot).
  3. While holding the knob in, light the pilot at the pilot burner.
  4. Keep holding the knob in for 30 to 60 seconds after the pilot lights.
  5. Release the knob slowly.
    • If the pilot stays lit, turn the knob to ON.
    • If it goes out, repeat the steps and hold the knob in a bit longer.
  6. Set the thermostat to the desired temperature and confirm the main burner ignites.

If the pilot will not stay lit

What we see Most common cause What we do next
Pilot lights, then goes out when we release the knob Thermocouple not hot enough or weak Hold longer; if still failing, plan a thermocouple check/replacement
No pilot flame at all Gas not reaching pilot or pilot orifice clogged Confirm gas supply is on; clean pilot area; service may be needed
Pilot flame is tiny/yellow Dirty pilot burner or low gas pressure Clean pilot burner area; have gas supply/pressure checked

Why it matters

A stable pilot flame is what allows the safety system (thermocouple and gas valve) to keep gas flowing safely. If the pilot is weak or won’t hold, the heater will not run reliably and can shut down repeatedly.

Helpful DIY reference

For basic electrical testing steps used during heater troubleshooting (when applicable), we use guidance like how to use a multimeter to test electrical parts video.

Last updated: February 2026

To adjust a Williams wall heater model 25GV-5, set the temperature with the control knob or thermostat on the heater (or a wall thermostat, if your installation uses one). Turn the setting up for more heat and down for less; then give the burner a few minutes to stabilize.

Safe adjustment steps (LPG wall heater)

  • Make sure the area around the wall furnace is clear of dust, lint, and stored items.
  • If the heater has a thermostat dial, start at a mid-range setting and adjust in small increments.
  • If it uses a wall thermostat, set your target room temperature and avoid frequent up/down changes.
  • After changing the setting, wait 5 to 10 minutes to judge the result (wall heaters respond gradually).
  • If you smell gas, shut the heater off, ventilate the area, and contact a qualified technician.

What the common controls mean

Control you see What it does Best practice
Thermostat dial on the heater Regulates room temperature automatically Use small changes; wait between adjustments
Manual heat level knob (low to high) Changes flame/heat output more directly Set to a steady level, then fine-tune with thermostat
Wall thermostat (if equipped) Cycles the heater to maintain set temp Keep a consistent setpoint for comfort

If the heater will not respond to adjustments

  • Confirm the heater is set to HEAT (not OFF).
  • Check that the pilot is lit (standing-pilot models) and the burner is able to ignite.
  • Replace thermostat batteries (if your wall thermostat uses them).
  • Make sure supply registers and return airflow are not blocked.
  • If the burner cycles rapidly or will not stay on, stop adjusting and have the heater serviced.

Why it matters

Correct adjustment helps your Williams 25GV-5 wall furnace heat evenly, reduces nuisance cycling, and can prevent overheating from running the control at maximum when a smaller setting would maintain comfort.

For model-specific parts diagrams and replacement parts, use the model page for 25GV-5 on Sears PartsDirect.

Last updated: February 2026

A Williams wall furnace such as model 25GV-5 burns LPG (propane) in a sealed burner area, then uses a heat exchanger to warm room air while venting combustion gases safely outside. A thermostat and gas valve control when it lights and how long it runs.

What happens during a normal heat cycle

  • The thermostat calls for heat.
  • The gas valve opens and the ignition system lights the burner (pilot or spark ignition, depending on the setup).
  • The flame heats the heat exchanger, not the room air directly.
  • Room air circulates across the heat exchanger (natural convection or a blower, if equipped).
  • Exhaust gases move into the vent/flue and out of the home.
  • When the set temperature is reached, the gas valve closes and the burner shuts off.

Key parts and what they do

Component What it does Common symptom if it fails
Thermostat Signals the furnace to start/stop No heat or short cycling
Gas valve Regulates gas flow to the burner No ignition or weak flame
Igniter/pilot Lights the burner Clicking but no flame, or pilot will not stay lit
Burner Mixes gas and air for combustion Yellow flame, soot, odor
Heat exchanger Transfers heat to room air Poor heat, unusual smells, overheating
Vent/flue Routes exhaust outdoors Backdrafting, shutdowns, soot around grille

Why it matters

Understanding the sequence helps you troubleshoot safely. For example, “no heat” can be thermostat related, ignition related, or gas supply related, while “runs but doesn’t warm” often points to airflow, burner flame quality, or venting.

Safe, practical checks you can do

  • Confirm the thermostat is set to HEAT and above room temperature.
  • Make sure the LPG supply valve is open and other gas appliances work.
  • Check that the front grille and louvers are not blocked by dust, rugs, or furniture.
  • Watch the flame through the viewing area (steady blue is typical; persistent yellow indicates a combustion issue).
  • If you smell gas, shut off the furnace and stop troubleshooting.

For general repair readiness and tool basics before you start any DIY work, use our guide: must have tools for appliance repair.

Last updated: February 2026

Most Williams wall heaters typically last 15 to 20 years. With clean combustion, correct gas pressure, and regular maintenance of the burner and venting, many units (including the Williams 25GV-5 LPG wall heater) run reliably beyond that range.

Typical lifespan (what to expect)

A wall furnace’s service life depends most on heat exchanger condition, burner cleanliness, and safe venting.

  • Typical lifespan: 15 to 20 years
  • Often lasts longer when: burner stays clean, flame is steady blue, and venting stays clear
  • Usually replaced sooner when: corrosion develops, overheating occurs, or venting problems persist

What shortens the life of an LPG wall heater

These are the most common causes of early failure in propane (LPG) wall furnaces:

  • Dust, lint, or pet hair restricting airflow through the cabinet
  • Burner ports clogged, causing delayed ignition or yellow tipping
  • Incorrect gas pressure or an undersized propane supply/regulator
  • Blocked or leaking venting (poor draft, soot, or repeated shutdowns)
  • Moisture exposure leading to rust and heat exchanger deterioration

Quick “repair vs. replace” guide

Use this as a practical decision check.

What you’re seeing What it usually means Best next step
Steady heat, normal ignition Normal operation Keep up annual cleaning and inspection
Frequent pilot/ignition issues Dirty burner, weak thermocouple/controls, draft issues Diagnose and service ignition and venting
Soot smell or visible soot Incomplete combustion or venting problem Stop using and have it inspected
Repeated overheating shutdowns Airflow restriction or internal damage Clean airflow path; inspect heat exchanger

Why it matters

Once a wall heater gets into the 15 to 20 year range, small combustion or venting issues can accelerate wear on critical components (especially the heat exchanger). Catching airflow, burner, and venting problems early helps extend life and keeps operation safe.

For general repair readiness and safe DIY planning, we recommend reviewing are diy appliance repairs safe and having the right basics on hand from must have tools for appliance repair.

Last updated: February 2026

Repair guides for front-engine lawn tractors

How to replace a blade clutch cable on a riding lawn mower

How to replace a blade clutch cable on a riding lawn mower

If the blades don't spin on your riding mower when you shift the lever, the blade clutch cable could be broken. Here’s h…

Repair time and Difficulty

 30 minutes or less
How to replace a ground drive belt on a riding lawn mower

How to replace a ground drive belt on a riding lawn mower

Replace the ground drive belt if it's broken or too worn to spin the transaxle pulley.…

Repair time and Difficulty

 45 minutes or less
How to replace a riding lawn mower blade drive belt

How to replace a riding lawn mower blade drive belt

Replace the blade drive belt if it's broken or won't spin the cutting blades because of wear.…

Repair time and Difficulty

 45 minutes or less

Articles and videos for front-engine lawn tractors

Should I get an electric riding mower?

Should I get an electric riding mower?

Get help deciding whether to make the switch to a battery-powered riding mower…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

Parts & More

Air Purifier
Chipper/Shredder
Dishwasher
Dryer
Electric Range
Freestanding Freezer
Furnace
Gas Line Trimmer
Lcd Television
Parts
Room Air Conditioner
Side-By-Side Refrigerator
Washer