Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Coleman PM0401851 generator

Coleman PM0401851 generator Parts

Here are the diagrams and repair parts for Coleman PM0401851 generator, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for PM0401851 Generator

  • Hose Clamp for Coleman PM0401851 - Part 0035857

    Generator diagram

    Hose Clamp

    Part #0035857

    The manufacturer no longer makes this part, and there's no substitute part

  • Grommet,sp for Coleman PM0401851 - Part 0049908

    Generator diagram

    Grommet,sp

    Part #0049908

    The manufacturer no longer makes this part, and there's no substitute part

  • Foot,rubbe for Coleman PM0401851 - Part 0047774

    Generator diagram

    Foot,rubbe

    Part #0047774

    The manufacturer no longer makes this part, and there's no substitute part

  • Brkt,lower for Coleman PM0401851 - Part 0049865

    Generator diagram

    Brkt,lower

    Part #0049865

    The manufacturer no longer makes this part, and there's no substitute part

  • Bttry,cble for Coleman PM0401851 - Part 0051291

    Generator diagram

    Bttry,cble

    Part #0051291

    The manufacturer no longer makes this part, and there's no substitute part

  • Lug,ground for Coleman PM0401851 - Part 0008854

    Generator diagram

    Lug,ground

    Part #0008854

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw for Coleman PM0401851 - Part 0049875

    Generator diagram

    Screw

    Part #0049875

    The manufacturer no longer makes this part, and there's no substitute part

  • Nut 5/16x18 for Coleman PM0401851 - Part 0008466

    Generator diagram

    Nut 5/16x18

    Part #0008466

    The manufacturer no longer makes this part, and there's no substitute part

  • Rotor for Coleman PM0401851 - Part 0049824

    Generator diagram

    Rotor

    Part #0049824

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt for Coleman PM0401851 - Part 0050144

    Generator diagram

    Bolt

    Part #0050144

    The manufacturer no longer makes this part, and there's no substitute part

Coleman Generator PM0401851 FAQs

The most common problems we see with the Coleman PM0401851 generator are no-start or hard-start conditions, low or no AC output, and surging under load. These issues usually trace back to fuel quality, ignition/spark, airflow, or basic electrical protection components.

Common symptoms and likely causes

  • Won’t start / starts then dies: stale fuel, clogged carburetor jets, dirty air filter, fouled spark plug, low oil shutdown (if equipped)
  • Surging or hunting: partially clogged carburetor, air leak at intake, fuel cap vent restriction, load too light
  • No AC output: tripped breaker, bad receptacle, loose wiring, failed capacitor (if used), loss of residual magnetism
  • Low voltage / weak power: overloaded generator, engine speed (RPM) too low, dirty connections, failing voltage regulation components
  • Runs rough: old fuel, water in fuel, restricted airflow, incorrect choke position

Quick checks we recommend (in order)

  1. Fuel: drain old gas; refill with fresh fuel (and stabilizer if it will sit).
  2. Air and spark: inspect/clean air filter; check spark plug condition and gap.
  3. Load test: unplug everything; start the generator; then add one known-good load at a time.
  4. Protection devices: reset any breakers; inspect outlets for heat damage.
  5. Basic electrical testing: verify AC output at the receptacle with a meter.

Simple troubleshooting table

Symptom What to check first What it points to
No start Fresh fuel, choke, spark plug Fuel delivery or ignition
Surging Carburetor cleanliness, air leaks Lean fuel mixture
No AC output Breaker reset, receptacle, wiring Output circuit issue
Low voltage Overload, engine RPM Speed regulation or load

Why it matters

Generators like the PM0401851 are sensitive to fuel varnish and small airflow restrictions; fixing the root cause prevents repeated no-starts, protects connected equipment from low voltage, and reduces overheating.

Helpful DIY resource

If you need to confirm whether power is present at the outlet or trace a wiring issue, use how to use a multimeter to test electrical parts video.

Last updated: March 2026

The Coleman generator model PM0401851 is typically equipped with a Briggs & Stratton 4-cycle engine in the 3 to 3.5 HP range. This is the common engine configuration used on this portable 1,500 running watt class generator.

How to confirm the exact engine on your unit

We recommend verifying the engine make and model from the engine’s ID label (not the generator frame label). Check these spots:

  • On the blower housing (recoil starter cover)
  • Near the spark plug area
  • On the valve cover or muffler side shroud
  • Stamped into the engine block (some versions)

If you find a Briggs & Stratton code set, it’s usually:

What you’ll see What it tells you
Model Engine family/model identifier
Type Configuration/version
Code Build date code

Why the engine ID matters for parts

On the PM0401851, many service items are engine-specific. Using the engine ID helps match the right:

  • Spark plug
  • Air filter
  • Carburetor or carburetor kit
  • Recoil starter parts
  • Fuel shutoff and fuel line fittings

Quick safety checks before inspecting

  • Shut the generator off and let it cool completely
  • Turn the fuel valve to OFF (if equipped)
  • Disconnect the spark plug wire before touching moving parts

For safe electrical testing and troubleshooting steps, use our guide: how to use a multimeter to test electrical parts video.

Why it matters

The generator model number (PM0401851) identifies the frame and alternator system, but the engine label is what ensures you get correct tune-up and fuel-system parts.

Last updated: February 2026

For a Coleman generator like model PM0401851, the 20/20/20 rule is a simple safety checklist: run the generator 20 feet from your home (away from doors, windows, and vents), let it cool 20 minutes before refueling, and use a $20 carbon monoxide (CO) alarm inside the home.

What each “20” means

  • 20 feet away: Reduces the risk of carbon monoxide entering living spaces.
  • 20 minutes to cool: Lowers the chance of fuel igniting on hot engine parts.
  • $20 CO alarm: Adds an extra layer of protection by alerting you to dangerous CO levels.

Quick setup checklist (PM0401851)

  • Place the generator outdoors on a firm, level surface.
  • Point the exhaust away from the house and any occupied areas.
  • Keep it at least 20 feet from doors, windows, soffit vents, crawlspace vents, and garage openings.
  • Shut the generator off and let it cool 20 minutes before adding fuel.
  • Use heavy-duty outdoor-rated extension cords (or a properly installed transfer setup) to prevent overheating and backfeed hazards.

Why it matters

Portable generators produce carbon monoxide and high heat. The 20/20/20 rule helps prevent CO poisoning, flash fires during refueling, and unsafe power connections during an outage.

20/20/20 at a glance

Rule step What you do What it helps prevent
20 feet Run outdoors, away from openings CO entering the home
20 minutes Cool down before refueling Fuel ignition, burns
$20 alarm Use a CO alarm indoors Delayed CO detection

Helpful DIY electrical testing tips

If you are troubleshooting power output, breakers, or wiring issues on a generator, safe testing practices matter.

  • Use the right meter setting before probing
  • Verify the meter on a known live source first
  • Inspect cords for cuts, melted insulation, or loose plugs

For a quick refresher, see how to use a multimeter to test electrical parts video.

Last updated: February 2026

Repair guides for side-by-side refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a press-in door gasket in a side-by-side refrigerator

How to replace a press-in door gasket in a side-by-side refrigerator

The door gasket seals the gap around the door to keep the cold air in and the warm air out. Replace a worn or damaged do…

Repair time and Difficulty

 15 minutes or less
How to replace an ice maker in a side-by-side refrigerator

How to replace an ice maker in a side-by-side refrigerator

Learn how to replace the ice maker in a side-by-side refrigerator with these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Articles and videos for side-by-side refrigerators

How to reset the door alarm on a GE refrigerator

How to reset the door alarm on a GE refrigerator

Your fridge is tattling again. Here’s how to reset the door alarm on your GE refrigerator—and how to tell if the beeping…

How to Replace the Water Filter in a Kenmore Pro Refrigerator

How to Replace the Water Filter in a Kenmore Pro Refrigerator

Discover how easy it is to replace the water filter in a Kenmore Pro refrigerator.…

Common Refrigerator Ice Maker Problems and Solutions

Common Refrigerator Ice Maker Problems and Solutions

Find tips on how to fix the ice maker in your fridge when it isn't working or when it isn't working right.…

Parts & More

Canister Vacuum
Dishwasher
Dryer
Electric Wall Oven
Parts
Refrigerator
Side-By-Side Refrigerator
Wall Oven/Microwave Combo
Washer