Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

Coleman PM0401851 generator Parts

Here are the diagrams and repair parts for Coleman PM0401851 generator, as well as links to manuals and error code tables, if available.

Coleman PM0401851 generator
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for PM0401851 Generator

  • Screw for Coleman PM0401851 - Part 0049874

    Generator diagram

    Screw

    Part #0049874

    The manufacturer no longer makes this part, and there's no substitute part

  • Hex Screw for Coleman PM0401851 - Part 0001537

    Generator diagram

    Hex Screw

    Part #0001537

    The manufacturer no longer makes this part, and there's no substitute part

  • Fuel Cap for Coleman PM0401851 - Part 0049841

    Generator diagram

    Fuel Cap

    Part #0049841

    The manufacturer no longer makes this part, and there's no substitute part

  • Nyloc 1/4x20 for Coleman PM0401851 - Part 0040832

    Generator diagram

    Nyloc 1/4x20

    Part #0040832

    The manufacturer no longer makes this part, and there's no substitute part

  • Fastener for Coleman PM0401851 - Part 0049846

    Generator diagram

    Fastener

    Part #0049846

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw for Coleman PM0401851 - Part 0049875

    Generator diagram

    Screw

    Part #0049875

    The manufacturer no longer makes this part, and there's no substitute part

  • Owner's Manual for Coleman PM0401851 - Part 0049860.06

    Generator diagram

    Owner's Manual

    Part #0049860.06

    The manufacturer no longer makes this part, and there's no substitute part

  • Foot,rubbe for Coleman PM0401851 - Part 0047774

    Generator diagram

    Foot,rubbe

    Part #0047774

    The manufacturer no longer makes this part, and there's no substitute part

  • Spacer for Coleman PM0401851 - Part 0048119

    Generator diagram

    Spacer

    Part #0048119

    The manufacturer no longer makes this part, and there's no substitute part

  • Shield,muf for Coleman PM0401851 - Part 0049923

    Generator diagram

    Shield,muf

    Part #0049923

    The manufacturer no longer makes this part, and there's no substitute part

Coleman Generator PM0401851 FAQs

The most common problems we see with the Coleman PM0401851 generator are no-start or hard-start conditions, low or no AC output, and surging under load. These issues usually trace back to fuel quality, ignition/spark, airflow, or basic electrical protection components.

Common symptoms and likely causes

  • Won’t start / starts then dies: stale fuel, clogged carburetor jets, dirty air filter, fouled spark plug, low oil shutdown (if equipped)
  • Surging or hunting: partially clogged carburetor, air leak at intake, fuel cap vent restriction, load too light
  • No AC output: tripped breaker, bad receptacle, loose wiring, failed capacitor (if used), loss of residual magnetism
  • Low voltage / weak power: overloaded generator, engine speed (RPM) too low, dirty connections, failing voltage regulation components
  • Runs rough: old fuel, water in fuel, restricted airflow, incorrect choke position

Quick checks we recommend (in order)

  1. Fuel: drain old gas; refill with fresh fuel (and stabilizer if it will sit).
  2. Air and spark: inspect/clean air filter; check spark plug condition and gap.
  3. Load test: unplug everything; start the generator; then add one known-good load at a time.
  4. Protection devices: reset any breakers; inspect outlets for heat damage.
  5. Basic electrical testing: verify AC output at the receptacle with a meter.

Simple troubleshooting table

Symptom What to check first What it points to
No start Fresh fuel, choke, spark plug Fuel delivery or ignition
Surging Carburetor cleanliness, air leaks Lean fuel mixture
No AC output Breaker reset, receptacle, wiring Output circuit issue
Low voltage Overload, engine RPM Speed regulation or load

Why it matters

Generators like the PM0401851 are sensitive to fuel varnish and small airflow restrictions; fixing the root cause prevents repeated no-starts, protects connected equipment from low voltage, and reduces overheating.

Helpful DIY resource

If you need to confirm whether power is present at the outlet or trace a wiring issue, use how to use a multimeter to test electrical parts video.

Last updated: March 2026

The Coleman generator model PM0401851 is typically equipped with a Briggs & Stratton 4-cycle engine in the 3 to 3.5 HP range. This is the common engine configuration used on this portable 1,500 running watt class generator.

How to confirm the exact engine on your unit

We recommend verifying the engine make and model from the engine’s ID label (not the generator frame label). Check these spots:

  • On the blower housing (recoil starter cover)
  • Near the spark plug area
  • On the valve cover or muffler side shroud
  • Stamped into the engine block (some versions)

If you find a Briggs & Stratton code set, it’s usually:

What you’ll see What it tells you
Model Engine family/model identifier
Type Configuration/version
Code Build date code

Why the engine ID matters for parts

On the PM0401851, many service items are engine-specific. Using the engine ID helps match the right:

  • Spark plug
  • Air filter
  • Carburetor or carburetor kit
  • Recoil starter parts
  • Fuel shutoff and fuel line fittings

Quick safety checks before inspecting

  • Shut the generator off and let it cool completely
  • Turn the fuel valve to OFF (if equipped)
  • Disconnect the spark plug wire before touching moving parts

For safe electrical testing and troubleshooting steps, use our guide: how to use a multimeter to test electrical parts video.

Why it matters

The generator model number (PM0401851) identifies the frame and alternator system, but the engine label is what ensures you get correct tune-up and fuel-system parts.

Last updated: February 2026

For a Coleman generator like model PM0401851, the 20/20/20 rule is a simple safety checklist: run the generator 20 feet from your home (away from doors, windows, and vents), let it cool 20 minutes before refueling, and use a $20 carbon monoxide (CO) alarm inside the home.

What each “20” means

  • 20 feet away: Reduces the risk of carbon monoxide entering living spaces.
  • 20 minutes to cool: Lowers the chance of fuel igniting on hot engine parts.
  • $20 CO alarm: Adds an extra layer of protection by alerting you to dangerous CO levels.

Quick setup checklist (PM0401851)

  • Place the generator outdoors on a firm, level surface.
  • Point the exhaust away from the house and any occupied areas.
  • Keep it at least 20 feet from doors, windows, soffit vents, crawlspace vents, and garage openings.
  • Shut the generator off and let it cool 20 minutes before adding fuel.
  • Use heavy-duty outdoor-rated extension cords (or a properly installed transfer setup) to prevent overheating and backfeed hazards.

Why it matters

Portable generators produce carbon monoxide and high heat. The 20/20/20 rule helps prevent CO poisoning, flash fires during refueling, and unsafe power connections during an outage.

20/20/20 at a glance

Rule step What you do What it helps prevent
20 feet Run outdoors, away from openings CO entering the home
20 minutes Cool down before refueling Fuel ignition, burns
$20 alarm Use a CO alarm indoors Delayed CO detection

Helpful DIY electrical testing tips

If you are troubleshooting power output, breakers, or wiring issues on a generator, safe testing practices matter.

  • Use the right meter setting before probing
  • Verify the meter on a known live source first
  • Inspect cords for cuts, melted insulation, or loose plugs

For a quick refresher, see how to use a multimeter to test electrical parts video.

Last updated: February 2026

Symptoms for top-mount refrigerators

Main causes: frozen or clogged defrost drain tube, cracked water system tubing…

Repair guides for top-mount refrigerators

How to replace the light switch in a top-freezer refrigerator

How to replace the light switch in a top-freezer refrigerator

The light switch turns the refrigerator light on and off and monitors door position. Replace the light switch if it does…

Repair time and Difficulty

 15 minutes or less
How to replace the water inlet valve in a top-freezer refrigerator

How to replace the water inlet valve in a top-freezer refrigerator

The water inlet valve controls water flow to the ice maker. Replace the water valve if it doesn't open or shut properly.…

Repair time and Difficulty

 15 minutes or less
How to replace the compressor run capacitor in a top-freezer refrigerator

How to replace the compressor run capacitor in a top-freezer refrigerator

The run capacitor sends electric current to the compressor motor to help the motor run efficiently. Replace the run capa…

Repair time and Difficulty

 15 minutes or less

Articles and videos for top-mount refrigerators

Can I fix my own fridge?

Can I fix my own fridge?

Find DIY repair tips to fix your refrigerator when it breaks down.…

How to replace Whirlpool refrigerator water filter EDR1RXD1 (EveryDrop Type 1)

How to replace Whirlpool refrigerator water filter EDR1RXD1 (EveryDrop Type 1)

Learn how to replace the Whirlpool EveryDrop 1 refrigerator water filter.…

How to replace open-tray-and-twist-out refrigerator water filters

How to replace open-tray-and-twist-out refrigerator water filters

Watch our video to see how to replace a refrigerator water filter located in a tray you open and then twist out the filt…

Parts & More

Canister Vacuum
Dishwasher
Dryer
Electric Wall Oven
Parts
Refrigerator
Side-By-Side Refrigerator
Wall Oven/Microwave Combo
Washer