Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Carrier 38CKC060300 condensing unit

Carrier 38CKC060300 condensing unit Parts

Here are the diagrams and repair parts for Carrier 38CKC060300 condensing unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 38CKC060300 Condensing Unit

  • Control Box Assembly for Carrier 38CKC060300 - Part 317456-710

    Control box diagram

    Control Box Assembly

    Part #317456-710

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel for Carrier 38CKC060300 - Part 317405-708138

    Outlet grille/top cover diagram

    Panel

    Part #317405-708138

    The manufacturer no longer makes this part, and there's no substitute part

  • Paint for Carrier 38CKC060300 - Part 313974-755

    Outlet grille/top cover diagram

    Paint

    Part #313974-755

    The manufacturer no longer makes this part, and there's no substitute part

  • Lug for Carrier 38CKC060300 - Part HY90AZ009

    Control box diagram

    Lug

    Part #HY90AZ009

    The manufacturer no longer makes this part, and there's no substitute part

  • Control Box for Carrier 38CKC060300 - Part 317404-404

    Control box diagram

    Control Box

    Part #317404-404

    The manufacturer no longer makes this part, and there's no substitute part

  • 085,kit,tvx(86-101) for Carrier 38CKC060300 - Part KSATX0601HSO

    Outlet grille/top cover diagram

    085,kit,tvx(86-101)

    Part #KSATX0601HSO

    The manufacturer no longer makes this part, and there's no substitute part

  • Control Bx for Carrier 38CKC060300 - Part 317406-774

    Outlet grille/top cover diagram

    Control Bx

    Part #317406-774

    The manufacturer no longer makes this part, and there's no substitute part

  • Carrier Valve Piston for Carrier 38CKC060300 - Part EA52PH093

    Outlet grille/top cover diagram

    Carrier Valve Piston

    Part #EA52PH093

    The manufacturer no longer makes this part, and there's no substitute part

  • 078,kit,l Ambient(79-81) for Carrier 38CKC060300 - Part KSALA0201R22

    Outlet grille/top cover diagram

    078,kit,l Ambient(79-81)

    Part #KSALA0201R22

    The manufacturer no longer makes this part, and there's no substitute part

  • Thermostat Cnvrsn Kit for Carrier 38CKC060300 - Part TSTATXXCNV10

    Outlet grille/top cover diagram

    Thermostat Cnvrsn Kit

    Part #TSTATXXCNV10

    The manufacturer no longer makes this part, and there's no substitute part

Carrier Condensing Unit 38CKC060300 FAQs

Most central air conditioning systems last 15 to 20 years with normal use and regular maintenance. For your Carrier condensing unit model 38CKC060300, keeping airflow unrestricted and staying on top of filter and coil care helps you reach the high end of that range (see the owner's manual).

Typical lifespan ranges (what to expect)

Lifespan depends most on maintenance, airflow, and how hard the system runs during hot weather.

System type Typical lifespan What shortens life fastest
Central AC (split system) 15 to 20 years Dirty filters, restricted airflow, dirty coils
Older or poorly maintained systems 10 to 12 years Rapid cycling, debris around outdoor unit

Maintenance that extends lifespan

The manual highlights several habits that directly reduce wear on the compressor and improve efficiency.

  • Never run the system without a clean air filter installed; a clogged filter raises operating cost and shortens unit life.
  • Keep supply and return registers unblocked (furniture, drapes, toys can restrict airflow).
  • Keep the outdoor unit clear; do not cover it or let leaves and grass clippings build up.
  • Maintain about 12 inches of clearance between the outdoor unit and tall grass, vines, or shrubs.
  • Avoid thermostat “jiggling” and wait at least 5 minutes before restarting after the compressor shuts off to prevent rapid cycling.

What “professional maintenance” should include

A thorough service visit (often seasonally, or at least every other year) typically covers:

  • Inspect and clean or replace air filter(s)
  • Inspect and clean indoor and outdoor coils
  • Check electrical wiring and connections
  • Verify secure physical connections of components
  • Run an operational check to confirm proper working condition

Why it matters

A central AC’s most expensive components (especially the compressor and fan motor) last longer when airflow is correct and the system does not short-cycle. Good maintenance also keeps energy use lower, so the unit runs less to deliver the same cooling.

Parts that commonly come up as systems age

If you are troubleshooting airflow or outdoor-unit operation on model 38CKC060300, these are common replacement categories:

For ordering, use the parts list for model 38CKC060300 or search by model number on Sears PartsDirect.

Last updated: February 2026

On most central AC systems, the most common failure is the run capacitor (it helps start and keep the compressor and condenser fan motor running). On your Carrier 38CKC060300 condensing unit, another very common failure point is the contactor, which switches high voltage power to the outdoor unit.

Most common failures you will see first

These parts fail often because they cycle frequently, run hot, and are sensitive to power issues:

  • Run capacitor (hard-start/run function for compressor and fan)
  • Contactor (power switching; pitted or stuck contacts)
  • Condenser fan motor (overheats, bearings wear, won’t start)
  • Fan blade/propeller (bent, loose, or out of balance)
  • Filter drier (restriction after a sealed-system repair)

If you suspect a fan-related issue on this model, the parts list includes the central air conditioner condenser fan motor HC39GE237 and the propeller LA01RA027. For operating and safety guidance, follow the 38CKC060300 owner's manual.

Quick symptom-to-part guide

What you notice outside Most likely area What it usually means
Outdoor unit hums but fan does not spin Capacitor or fan motor Weak capacitor or failing motor
Outdoor unit will not run at all Contactor or power supply Contactor not pulling in, or no power
Fan runs but air is not cool Refrigerant/coil/airflow Possible restriction, leak, or dirty coil
Short cycling (on and off quickly) Controls/thermostat behavior Rapid cycling can stress the compressor

Why it matters

Catching a failing capacitor or contactor early helps prevent repeated hard starts and rapid cycling, which can shorten compressor life. The manual also emphasizes keeping airflow unrestricted and using the thermostat correctly to avoid damaging operation.

What we recommend before replacing parts

  • Turn off power at the disconnect and breaker before inspecting the outdoor unit.
  • Check for debris around the condenser and keep clearance around the unit.
  • Confirm the thermostat is controlling the system (avoid switching power on and off to control cooling).
  • If you are testing electrical components, use proper meter technique and safe procedures.
  • Order model-matched parts from the parts list for Carrier 38CKC060300, or search by model on Sears PartsDirect.

Last updated: February 2026

The Carrier 38CKC060300 is a 5-ton central air conditioner (about 60,000 BTU/hr). In Carrier model numbering, the “060” capacity code indicates roughly 60,000 BTU per hour; divide by 12,000 BTU per ton to get 5 tons.

Quick tonnage math (how we get 5 tons)

  • Nominal capacity code: 060
  • Approximate cooling capacity: 60,000 BTU/hr
  • Conversion: 12,000 BTU/hr = 1 ton
  • Result: 60,000 ÷ 12,000 = 5 tons
Model capacity code Approx. BTU/hr Approx. tons
030 30,000 2.5
036 36,000 3
048 48,000 4
060 60,000 5

Why the exact tonnage matters

Correct tonnage affects comfort and reliability. An oversized condensing unit can short-cycle and struggle with humidity control; an undersized unit can run constantly and still not keep up on hot days.

What to check on the unit to confirm

Even though “060” is the standard capacity indicator, we recommend confirming the rating plate and system match:

  • Outdoor unit data plate: look for cooling capacity or BTU/hr
  • Indoor coil and air handler/furnace match (mismatched coils can change performance)
  • Refrigerant type listed on the data plate (older systems are often R-22)
  • Electrical rating (voltage and phase) to ensure the replacement parts match

For model-specific operation and maintenance details, use the owner's manual.

If you are troubleshooting poor cooling, these parts on this model are often involved:

If you need to order parts for Carrier 38CKC060300, start with the parts list for this model, or search by model number on Sears PartsDirect.

Last updated: February 2026

Symptoms for table saws

Choose a symptom to see related table saw repairs.

Main causes: blade alignment needs adjustment, worn blade, bevel positive stops need adjustments, bevel pointer needs ad…

Main causes: dirty saw blade, dull or damaged saw blade, blade alignment needs adjustment…

Main causes: saw dust build up, blade elevating and tilting mechanisms need lubrication…

Main causes: worn motor brushes, bad drive motor, faulty overload switch, using an improper extension cord, binding saw …

Main causes: worn motor brushes, faulty drive motor, using an improper extension cord…

Main causes: lack of power, broken on/off switch, bad motor overload, broken power cord, bad drive motor…

Repair guides for table saws

These step-by-step repair guides will help you safely fix what’s broken on your table saw.

How to replace a table saw drive motor

How to replace a table saw drive motor

You can replace a table saw drive motor that is weak or won't run. Here’s how.…

Repair time and Difficulty

 45 minutes or less
How to replace a table saw blade

How to replace a table saw blade

If the table saw blade is dull or damaged, use these simple steps to replace it.…

Repair time and Difficulty

 15 minutes or less
How to replace a table saw motor brush set

How to replace a table saw motor brush set

Worn motor brushes can make the table saw motor run weak. Here’s how to replace them. …

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your central air conditioners

Use the advice and tips in these articles to get the most out of your table saw.

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Blender
Bottom-Mount Refrigerator
Cooktop
Dishwasher
Electric Chainsaw
Electric Leaf Blower
Electronic Sewing Machine
Front-Engine Lawn Tractor
Furnace
Gas Cooktop
Line Trimmer
Parts
Rear-Engine Riding Mower
Refrigerator
Side-By-Side Refrigerator
Table Saw