  • Control Lo P for ICP CA9636VKA1 - Part 1071932

    Functional replacement parts diagram

    Control Lo P

    In Stock
    $185.59
    Minus Item
    Qty
    Plus Item
  • Motor Mount for ICP CA9636VKA1 - Part 1052968

    Functional replacement parts diagram

    Motor Mount

    In Stock
    $36.96
    Minus Item
    Qty
    Plus Item
  • Fit Plate for ICP CA9636VKA1 - Part 1052849

    Functional replacement parts diagram

    Fit Plate

    In Stock
    $501.22
    Minus Item
    Qty
    Plus Item
  • Jacket Scrl for ICP CA9636VKA1 - Part 1068472

    Functional replacement parts diagram

    Jacket Scrl

    In Stock
    $877.49
    Minus Item
    Qty
    Plus Item
  • Valve Suct for ICP CA9636VKA1 - Part 1080995

    Functional replacement parts diagram

    Valve Servic

    Part #1063718

    Replaced by #1080995

    Info Icon
    Manufacturer substitution
    This part replaces 1063718. Substitute parts can look different from the original.
    In Stock
    $239.40
    Minus Item
    Qty
    Plus Item
  • 50+5 Mfd 440 for ICP CA9636VKA1 - Part TRCFD505

    Functional replacement parts diagram

    Cap Rnrd

    Part #1094993

    Replaced by #TRCFD505

    Info Icon
    Manufacturer substitution
    This part replaces 1094993. Substitute parts can look different from the original.
    In Stock
    $44.13
    Minus Item
    Qty
    Plus Item
  • Timer for ICP CA9636VKA1 - Part 1060410

    Functional replacement parts diagram

    Timer

    Part #1060410

    The manufacturer no longer makes this part, and there's no substitute part

  • Base for ICP CA9636VKA1 - Part 1084554

    Functional replacement parts diagram

    Base Panel

    Part #1068672

    Replaced by #1084554

    Info Icon
    Manufacturer substitution
    This part replaces 1068672. Substitute parts can look different from the original.
    In Stock
    $107.62
    Minus Item
    Qty
    Plus Item
  • Fan for ICP CA9636VKA1 - Part 1085840

    Functional replacement parts diagram

    Fan Blade

    Part #1053342

    Replaced by #1085840

    Info Icon
    Manufacturer substitution
    This part replaces 1053342. Substitute parts can look different from the original.
    In Stock
    $245.72
    Minus Item
    Qty
    Plus Item
  • Valve for ICP CA9636VKA1 - Part 1080999

    Functional replacement parts diagram

    Valve Servic

    Part #1063722

    Replaced by #1080999

    Info Icon
    Manufacturer substitution
    This part replaces 1063722. Substitute parts can look different from the original.
    In Stock
    $330.89
    Minus Item
    Qty
    Plus Item

ICP Central Air Conditioner CA9636VKA1 FAQs

For your Icp central air conditioner model CA9636VKA1, the fastest way to find the correct replacement parts is to match the exact model number on the unit’s data plate, then choose the part from the CA9636VKA1 parts list so the electrical ratings and fit are correct.

Step-by-step: find the right part for CA9636VKA1
  • Confirm the model number CA9636VKA1 on the outdoor condenser unit label.
  • Identify the system symptom (no cooling, fan not running, won’t start, buzzing).
  • Locate the matching part category (electrical controls, fan, capacitor, service valves).
  • Compare the part name and ID to what you need before ordering.
  • If you are troubleshooting, test safely with proper tools before replacing parts.
Common CA9636VKA1 parts customers replace

These are frequently involved when the outdoor unit will not start, the condenser fan will not run, or the unit short-cycles:

Symptom Likely area Example part on this model page
Outdoor unit won’t start Switching/control Fan control 1053553
Fan not spinning, compressor runs Fan motor/blade Central air conditioner condenser fan motor 1053217
Hums, struggles to start Run capacitor Cap rnrd TRCFD505
Quick safety and troubleshooting checks
  • Turn off power at the disconnect and breaker before opening the condenser panel.
  • Look for burned wires, loose spade connectors, or overheated terminals.
  • Check the condenser fan blade for wobble, rubbing, or damage.
  • If you suspect an electrical issue, use a meter correctly before replacing components.

Helpful DIY references we use:

Why it matters

Central air conditioner parts are not “one size fits all”. Matching the CA9636VKA1 model and selecting the exact control, motor, or capacitor helps prevent incorrect voltage or microfarad ratings, nuisance failures, and repeat service calls.

Last updated: February 2026

Replacing a central AC unit typically costs about $6,000 on average, with many full replacements landing in the $1,500 to $12,500 range depending on system size (tons/BTU), efficiency (SEER2), ductwork condition, electrical upgrades, and local labor rates. For your Icp CA9636VKA1, the exact total depends on what is being replaced and what your home needs.

What drives the price most
  • System size and capacity (larger homes need larger condensers and coils)
  • Efficiency level (SEER2) and any required matching indoor coil changes
  • Ductwork repairs or modifications (leaks, resizing, adding returns)
  • Electrical and code updates (disconnect, breaker, wiring, pad, surge protection)
  • Refrigerant-related work (line set condition, evacuation, charging)
  • Labor rates and access (tight installs, rooftop, long line sets)
Replace the whole system or repair the outdoor unit?

If your CA9636VKA1 is not cooling, a repair can sometimes restore operation for far less than a full replacement, especially when the issue is electrical or airflow-related.

Option Best when Typical scope
Repair Unit is otherwise in good shape and failure is isolated Replace a failed electrical or fan component, test, and restart
Replace outdoor unit only Outdoor section is failing but indoor coil is compatible New condenser, possible line set work
Full system replacement Multiple major issues or efficiency upgrade goals New condenser + indoor coil (and sometimes furnace/air handler)
Common repair parts that can prevent a full replacement

These are frequent failure points on outdoor condensers and are available for CA9636VKA1:

Why it matters

A central AC replacement quote often includes more than the equipment. Knowing whether the problem is a single failed part (like a capacitor, contactor, or condenser fan motor) helps you decide if a targeted repair makes sense before committing to a full system changeout.

Last updated: February 2026

Most central air conditioning units last 15 to 20 years with normal use and regular maintenance. For an Icp CA9636VKA1 central air conditioner, reaching the high end of that range depends on keeping airflow unrestricted and the outdoor unit’s electrical and fan components operating correctly.

Typical lifespan ranges (what to expect)
  • 15 to 20 years: common for modern central AC systems with routine upkeep
  • 10 to 12 years: common when maintenance is skipped or the system runs under heavy strain
  • Earlier replacement: more likely with chronic overheating, repeated electrical failures, or long-term airflow restrictions
What shortens (or extends) AC life

These are the most common conditions that reduce service life:

  • Dirty air filter or restricted return air (low airflow)
  • Outdoor condenser coil packed with debris (poor heat transfer)
  • Frequent hard starts (electrical wear)
  • Overheating from a weak condenser fan motor or damaged fan blade
  • Loose or burned electrical connections in the outdoor unit
Quick maintenance checklist (high impact)
  • Replace or clean the air filter on schedule (often every 1 to 3 months)
  • Keep vegetation and debris away from the outdoor condenser
  • Gently rinse the outdoor coil (power off first)
  • Confirm the condenser fan starts quickly and runs smoothly
  • Schedule seasonal electrical and refrigerant checks as needed
Parts that commonly affect reliability

If your system is aging, these parts are often involved in “no cool” or “won’t start” problems:

Part What it does Common symptom when failing
Central air conditioner condenser fan motor 1053217 Moves air across the condenser coil Overheating, shutdowns, weak cooling
Fan control 1053553 Controls fan operation Fan not running, intermittent operation
Cap rnrd TRCFD505 Helps motors start and run Humming, hard starts, fan not spinning
Why it matters

Once a central AC is in the 15 to 20 year range, repeated “no start” or overheating issues usually point to age-related wear. If it is younger, correcting airflow and fan or electrical problems often restores reliable cooling.

Last updated: February 2026

On most central air conditioners (including Icp model CA9636VKA1), the compressor is typically the most expensive single component to replace because it is the core of the refrigerant system and the repair often includes significant labor and refrigerant handling.

Typical high-cost AC parts (and why)
  • Compressor: highest part cost; labor-intensive sealed-system work
  • Condenser coil: expensive coil plus refrigerant recovery and recharge
  • Control board/inverter (on some systems): costly electronics and diagnostics
  • Refrigerant leak repair: cost varies widely based on access and leak location
  • Fan motor: moderate-to-high cost; can be a major repair on some models
What you can price on this CA9636VKA1 parts list

Even when the compressor is the most expensive overall, common “big ticket” repairs on the outdoor unit often involve the fan and electrical controls. Examples from the CA9636VKA1 parts list include:

Quick comparison (part cost vs. typical impact)
Part type What it affects Typical symptom when failing
Compressor Cooling and refrigerant circulation Hums/trips breaker, no cooling, hard start
Condenser fan motor Heat rejection at outdoor unit Outdoor fan not spinning, overheating shutdown
Contactor/capacitor Starting and power switching Clicking, intermittent start, buzzing
How to decide: repair vs. replace
  • Compare repair total (parts + labor) to the unit’s age and overall condition
  • If the compressor is involved, get a firm diagnosis first; misdiagnosis is common
  • If the issue is electrical (contactor, capacitor, fan control), repairs are often more cost-effective
Why it matters

The “most expensive part” question is really about risk: compressor and sealed-system repairs carry the highest cost and the highest chance that other wear issues show up soon after.

Last updated: February 2026

Repair guides for side-by-side refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a press-in door gasket in a side-by-side refrigerator

How to replace a press-in door gasket in a side-by-side refrigerator

The door gasket seals the gap around the door to keep the cold air in and the warm air out. Replace a worn or damaged do…

Repair time and Difficulty

 15 minutes or less
How to replace an ice maker in a side-by-side refrigerator

How to replace an ice maker in a side-by-side refrigerator

Learn how to replace the ice maker in a side-by-side refrigerator with these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your central air conditioners

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Audio Equipment
Electric Range
Garbage Disposal
Gas Chainsaw
Parts
Side-By-Side Refrigerator
Top-Mount Refrigerator
Washer