Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
ICP CA9030VKA2 cooling condenser

ICP CA9030VKA2 cooling condenser Parts

Here are the diagrams and repair parts for ICP CA9030VKA2 cooling condenser, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for CA9030VKA2 Cooling Condenser

  • Access Panel for ICP CA9030VKA2 - Part 1052800

    Non-functional replacement parts diagram

    Access Panel

    In Stock
    $55.81
    Minus Item
    Qty
    Plus Item
  • Condenser for ICP CA9030VKA2 - Part 1061896

    Functional replacement parts diagram

    Condenser

    In Stock
    $29.46
    Minus Item
    Qty
    Plus Item
  • Motor Mount for ICP CA9030VKA2 - Part 1052968

    Functional replacement parts diagram

    Motor Mount

    In Stock
    $36.96
    Minus Item
    Qty
    Plus Item
  • Compressor for ICP CA9030VKA2 - Part 1052809

    Functional replacement parts diagram

    Compressor

    In Stock
    $63.25
    Minus Item
    Qty
    Plus Item
  • Valve for ICP CA9030VKA2 - Part 1080999

    Functional replacement parts diagram

    Valve Servic

    Part #1063722

    Replaced by #1080999

    Info Icon
    Manufacturer substitution
    This part replaces 1063722. Substitute parts can look different from the original.
    In Stock
    $330.89
    Minus Item
    Qty
    Plus Item
  • Fan for ICP CA9030VKA2 - Part 1085840

    Functional replacement parts diagram

    Fan Blade

    Part #1053342

    Replaced by #1085840

    Info Icon
    Manufacturer substitution
    This part replaces 1053342. Substitute parts can look different from the original.
    In Stock
    $245.72
    Minus Item
    Qty
    Plus Item
  • Valve Suct for ICP CA9030VKA2 - Part 1080995

    Functional replacement parts diagram

    Valve Servic

    Part #1063718

    Replaced by #1080995

    Info Icon
    Manufacturer substitution
    This part replaces 1063718. Substitute parts can look different from the original.
    In Stock
    $239.40
    Minus Item
    Qty
    Plus Item
  • Users Guide for ICP CA9030VKA2 - Part 1053084

    #NI

    All parts diagram

    Users Guide

    Part #1053084

    The manufacturer no longer makes this part, and there's no substitute part

  • Inlet Grille for ICP CA9030VKA2 - Part 1053369

    Non-functional replacement parts diagram

    Inlet Grille

    Part #1053369

    The manufacturer no longer makes this part, and there's no substitute part

  • C-box Cover for ICP CA9030VKA2 - Part 1052702

    Non-functional replacement parts diagram

    C-box Cover

    Part #1052702

    The manufacturer no longer makes this part, and there's no substitute part

ICP Cooling Condenser CA9030VKA2 FAQs

A central air conditioning system typically costs $3,000 to $15,000+ installed, depending on system size (tonnage), efficiency (SEER2), and installation complexity. For an Icp CA9030VKA2 outdoor condenser, the biggest price swings usually come from labor, ductwork, and electrical work, not the cabinet itself.

What drives the price most

  • System size (tons/BTU capacity): larger capacity equipment and more labor cost more
  • Efficiency (SEER2): higher efficiency usually increases equipment cost
  • Installation complexity: pad, electrical disconnect, line-set routing, and refrigerant work
  • Ductwork condition: sealing, repairs, or resizing can add significant cost
  • Indoor equipment needs: evaporator coil plus furnace or air handler compatibility
  • Permits and code requirements: varies by location

Typical installed cost ranges

Scenario Typical range What’s usually included
Basic condenser and indoor coil replacement $3,000 to $7,000 Swap-out when ducts and electrical are in good shape
Higher-efficiency upgrade $6,000 to $12,000 More setup, commissioning, and sometimes additional components
Ductwork or electrical modifications needed $10,000 to $15,000+ Duct repairs, new circuits, disconnect, or major airflow corrections

Quick checks before you compare quotes

  • Confirm the exact model number CA9030VKA2 and match the indoor coil and metering device
  • Ask whether the quote includes a new line set, filter drier, and refrigerant charge
  • Verify the contractor will measure airflow and static pressure, not just replace equipment
  • Make sure start-up includes electrical checks of components such as the contactor and fan motor

Why it matters

A low bid often skips airflow and commissioning steps that prevent short cycling, poor comfort, and high energy use. Proper sizing and installation reduces strain on key components and helps the system run reliably.

If you are repairing (not replacing) a CA9030VKA2, common service parts include the central air conditioner condenser fan motor 1053217 and the fan blade 1085840.

Last updated: January 2026

The “best” central air conditioner brand is the one that matches your home’s load calculation, has strong local installer support, and offers the efficiency and features you want. For an Icp CA9030VKA2 condenser, brand quality matters, but correct sizing and installation matter more.

Brands that are commonly rated highly

Most homeowners and HVAC pros tend to put these brands in the top tier for reliability and dealer support (availability varies by region):

  • Carrier
  • Trane
  • Lennox
  • Rheem
  • American Standard
  • York
  • Goodman
  • Bryant

What to compare when choosing a brand

Use these factors to compare models across brands, not just the logo on the cabinet:

  • SEER2/EER2 efficiency: higher efficiency can lower operating cost
  • Compressor type: single-stage, two-stage, or variable-speed (comfort and noise)
  • Sound ratings: quieter outdoor units improve comfort near patios and bedrooms
  • Warranty terms: parts coverage length and any registration requirements
  • Local parts and service availability: fast repairs depend on local supply
  • Compatibility: matching indoor coil and thermostat controls

Quick comparison guide

What you care about What to look for Why it helps
Lower energy bills Higher SEER2, properly matched system Reduces run cost when sized correctly
Best comfort Two-stage or variable-speed More even temperatures and humidity control
Quiet operation Lower published dB rating Less outdoor noise
Fewer repair delays Strong local dealer network Faster diagnosis and parts sourcing

Why it matters

Central air conditioners are a “system,” not just an outdoor unit. Even a premium brand can perform poorly if the unit is oversized, airflow is wrong, or refrigerant charge is off. A properly installed mid-tier system often outperforms a poorly installed top-tier system.

Helpful part note for Icp CA9030VKA2 owners

If you are evaluating repair versus replace, the condition of key components can influence the decision. Common service items on this model include the central air conditioner condenser fan motor 1053217 and the contactor (a frequent electrical wear item).

Last updated: January 2026

Most central air conditioning units last 15 to 20 years with normal use and regular maintenance; for an Icp CA9030VKA2 outdoor cooling condenser, keeping airflow clear and electrical components healthy is what most often determines whether you reach the high end of that range.

Typical lifespan ranges

Unit condition Typical lifespan What usually shortens life
Well maintained 15 to 20 years Dirty coil, restricted airflow, electrical wear
Minimal maintenance 10 to 15 years Overheating, hard starts, corrosion
Harsh conditions (coastal, heavy run time) 8 to 12 years Salt corrosion, constant cycling, vibration

What to do to help your CA9030VKA2 reach 15 to 20 years

  • Keep the outdoor coil and cabinet free of leaves, grass clippings, and lint.
  • Maintain 18 to 24 inches of clearance around the condenser for proper airflow.
  • Replace or clean the indoor air filter regularly (a clogged filter raises system strain).
  • Watch for frequent clicking, buzzing, or hard-start symptoms; those often point to a failing contactor or motor.
  • Have a technician check refrigerant charge and electrical connections during seasonal service.

Parts that commonly affect reliability

If the condenser will not start, starts intermittently, or the fan does not run, these model-matched parts are common suspects:

Why it matters

A central air conditioner that is nearing end-of-life often costs more to run and is more likely to fail during peak heat. Simple airflow and electrical checks reduce overheating and repeated start stress, which are two of the biggest lifespan killers for outdoor condensers.

Last updated: January 2026

Symptoms for top-mount refrigerators

Main causes: frozen or clogged defrost drain tube, cracked water system tubing…

Repair guides for top-mount refrigerators

How to replace the light switch in a top-freezer refrigerator

How to replace the light switch in a top-freezer refrigerator

The light switch turns the refrigerator light on and off and monitors door position. Replace the light switch if it does…

Repair time and Difficulty

 15 minutes or less
How to replace the water inlet valve in a top-freezer refrigerator

How to replace the water inlet valve in a top-freezer refrigerator

The water inlet valve controls water flow to the ice maker. Replace the water valve if it doesn't open or shut properly.…

Repair time and Difficulty

 15 minutes or less
How to replace the compressor run capacitor in a top-freezer refrigerator

How to replace the compressor run capacitor in a top-freezer refrigerator

The run capacitor sends electric current to the compressor motor to help the motor run efficiently. Replace the run capa…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your central air conditioners

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Accessory
Dryer
Electric Water Heater
Front-Engine Lawn Tractor
Gas Walk-Behind Mower
Laundry Center
Parts
Side-By-Side Refrigerator