Frigidaire
Chest Freezer

Model #CF5NL2 Frigidaire chest freezer - 5995203576

Here are the diagrams and repair parts for Frigidaire CF5NL2 chest freezer - 5995203576, as well as links to manuals and error code tables, if available.


There are a couple of ways to find the part or diagram you need:

  • Click a diagram to see the parts shown on that diagram.
  • In the search box below, enter all or part of the part number or the part’s name.

Not all parts are shown on the diagrams—those parts are labeled NI, for “not illustrated”.

We encourage you to save the model to your profile, so it’s easy to access parts and manuals for your appliance whenever you log in.

For DIY troubleshooting advice and repair guides, visit our repair help section.

Save to my profileError Codes

Showing 10 of 53 parts

Freezer Access Panel Retainer

#27

Chest freezer parts Diagram

Freezer access panel retainer

Part #08017037
This item is not returnable
$2.51

In Stock

Freezer Compressor Overload Protector

#33

Chest freezer parts Diagram

$127.73

In Stock

Terminal Cover

#35

Chest freezer parts Diagram

Terminal cover

Part #5303206815
$9.49

In Stock

Freezer Condenser Coil

#19

Chest freezer parts Diagram

Freezer condenser coil

Part #5300120779
$182.37 | 
43% OFF MSRP:$320.00

In Stock

Refrigerator Evaporator Cover Screw

#39

Chest freezer parts Diagram

Refrigerator evaporator cover screw

Part #08037851
This item is not returnable
$2.16 | 
38% OFF MSRP:$3.50

In Stock

Gasket

#7

Chest freezer parts Diagram

Gasket

Part #5308037990
$36.06

In Stock

Freezer Basket Bumper

#21

Chest freezer parts Diagram

Freezer basket bumper

Part #5305878546
This item is not returnable
$4.62

In Stock

Freezer Lid Hinge Screw

#10

Chest freezer parts Diagram

Freezer lid hinge screw

Part #5309950602
This item is not returnable
$3.60

In Stock

Freezer Gasket and Liner Fastener Kit

#8

Chest freezer parts Diagram

Freezer gasket and liner fastener kit

Part #5304406520
?
Manufacturer substitution
This part replaces 5303922007. Substitute parts can look different from the original.
This part replaces 5303922007
$13.74 | 
14% OFF MSRP:$16.00

In Stock

Refrigerator Door Insulation

#5

Chest freezer parts Diagram

Refrigerator door insulation

Part #5303917276
?
Manufacturer substitution
This part replaces 5303207270. Substitute parts can look different from the original.
This part replaces 5303207270
$136.86 | 
43% OFF MSRP:$240.00

In Stock

Symptoms common to all freestanding freezers

Choose a symptom to see related freezer repairs.

Main causes: lack of power, bad compressor, refrigerant leak, bad thermistor, defrost system failure, dirty condenser coils, control failure
Main causes: leaky door or lid gasket, broken defrost heater, bad defrost bi-metal thermostat, defrost control failure, faulty compressor
Main causes: dirty condenser coils, condenser fan failure, dirty bottom front grill, leaky door or lid gasket
Main causes: burned out light bulb, bad door or lid switch, faulty LED light board, wiring failure, control system failure
Main causes: damaged door or lid gasket, cracked cabinet liner, bad defrost bi-metal thermostat, broken defrost heater, bad defrost timer
Main causes: lack of power, control system failure, broken compressor start relay, locked up compressor, compressor motor failure
Main causes: compressor failure, no refrigerant, faulty sensor, control failure, broken defrost heater, bad defrost bi-metal thermostat
Main causes: excessive frost, bad defrost heater, bad defrost bi-metal, control system failure, low refrigerant charge, compressor problems

Repair guides for chest freezers

February 20, 2015
By Lyle Weischwill
How to replace a freezer compressor start relay

The compressor start relay starts the compressor. If the compressor won’t start, follow these steps to replace a defective compressor start relay.

Repair difficulty
Time required
 15 minutes or less
How to replace a freezer temperature control thermostat

The cold control thermostat regulates the freezer temperature. A defective cold control thermostat can prevent the compressor from cycling on or off. Follow these steps to replace a defective cold control thermostat.

Repair difficulty
Time required
 15 minutes or less
February 1, 2015
By Lyle Weischwill
How to replace a freezer lid gasket

The lid gasket prevents air and moisture from entering the freezer when the lid is closed. Follow these steps to replace a torn or damaged lid gasket.

Repair difficulty
Time required
 30 minutes or less

Articles and videos common to all freestanding freezers

Use the advice and tips in these articles and videos to get the most out of your freezer.

October 26, 2016

How to repair broken or damaged wires video

By Sears PartsDirect staff

Learn how to repair broken, frayed or damaged wires in your appliances.

January 18, 2016

How to use a multimeter to test electrical parts video

By Sears PartsDirect staff

Learn how to use a multimeter to check for wiring problems in an appliance that's not working

November 1, 2014

Freezer common questions

By Sears PartsDirect staff

Benefit from other people's experience by checking on these frequently asked questions about freezers.