Ruud URKA-A24 gas/electric package unit Parts

Here are the diagrams and repair parts for Ruud URKA-A24 gas/electric package unit, as well as links to manuals and error code tables, if available.

Ruud URKA-A24 gas/electric package unit
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for URKA-A24 Gas/Electric Package Unit

  • Coil Condens for Ruud URKA-A24 - Part AS-58677-06

    #44A

    All parts diagram

  • Blower Assembly for Ruud URKA-A24 - Part AS-58662-01

    #48

    All parts diagram

  • Conversion for Ruud URKA-A24 - Part 60-22513-03

    #73A

    All parts diagram

    Convrsn Assy

    Part #60-22513-01

    Replaced by #60-22513-03

    Info Icon
    Manufacturer substitution
    This part replaces 60-22513-01. Substitute parts can look different from the original.
    In Stock
    $97.86
    Minus Item
    Qty
    Plus Item
  • Spk Module for Ruud URKA-A24 - Part 62-23556-82

    #72

    All parts diagram

    Spark Module

    Part #62-23556-01

    Replaced by #62-23556-82

    Info Icon
    Manufacturer substitution
    This part replaces 62-23556-01. Substitute parts can look different from the original.
    In Stock
    $145.10
    Minus Item
    Qty
    Plus Item
  • Compressor for Ruud URKA-A24 - Part ZR18K5E-PFV-800

    #56B

    All parts diagram

    Compressor

    Part #55-23139-03S

    Replaced by #ZR18K5E-PFV-800

    Info Icon
    Manufacturer substitution
    This part replaces 55-23139-03S. Substitute parts can look different from the original.
    In Stock
    $1610.42
    Minus Item
    Qty
    Plus Item
  • Central Air Conditioner Heat Exchanger for Ruud URKA-A24 - Part AS-58632-86

    #NI14

    All parts diagram

    Heat Exchange

    Part #AS-58632-02

    Replaced by #AS-58632-86

    Info Icon
    Manufacturer substitution
    This part replaces AS-58632-02. Substitute parts can look different from the original.
    In Stock
    $1362.73
    Minus Item
    Qty
    Plus Item
  • Limit Switch for Ruud URKA-A24 - Part 470015

    Limit Switch

    Part #47-23610-03

    Replaced by #470015

    Info Icon
    Manufacturer substitution
    This part replaces 47-23610-03. Substitute parts can look different from the original.
    In Stock
    $53.65
    Minus Item
    Qty
    Plus Item
  • Start Kit for Ruud URKA-A24 - Part SK-A1

    #NI03

    All parts diagram

    Start Kit

    Part #SK-A1-1

    Replaced by #SK-A1

    Info Icon
    Manufacturer substitution
    This part replaces SK-A1-1. Substitute parts can look different from the original.
    In Stock
    $130.88
    Minus Item
    Qty
    Plus Item
  • Ht Exch Ay for Ruud URKA-A24 - Part AS-58632-88

    #NI16

    All parts diagram

    Ht Exch Ay

    Part #AS-58632-04

    Replaced by #AS-58632-88

    Info Icon
    Manufacturer substitution
    This part replaces AS-58632-04. Substitute parts can look different from the original.
    In Stock
    $1782.66
    Minus Item
    Qty
    Plus Item
  • Compressor for Ruud URKA-A24 - Part ZR25K5E-PFV-800

    #56C

    All parts diagram

    Compressor

    Part #55-23139-10S

    Replaced by #ZR25K5E-PFV-800

    Info Icon
    Manufacturer substitution
    This part replaces 55-23139-10S. Substitute parts can look different from the original.
    In Stock
    $1663.60
    Minus Item
    Qty
    Plus Item

Ruud Gas/Electric Package Unit URKA-A24 FAQs

For a 3,000 sq ft home, a new heat pump system typically costs about $6,000 to $15,000 installed, with higher totals when you need ductwork changes, electrical upgrades, or a higher-efficiency (variable-speed) setup. Your Ruud URKA-A24 is a gas/electric package unit, so a heat pump quote often includes additional equipment and labor to convert the system type.

What drives the price most

  • Heat pump size (tonnage) needed for your climate and insulation level
  • Efficiency rating (higher efficiency usually costs more up front)
  • Ductwork condition (repairs, resizing, sealing, or replacement)
  • Electrical work (breaker, wiring, disconnect, or panel capacity)
  • Installation complexity (roof curb, pad, crane, refrigerant line routing)
  • Permits and local code requirements

Typical cost ranges (installed)

Scenario What you’re paying for Typical range
Basic replacement Standard efficiency, minimal changes $6,000 to $10,000
Mid-range upgrade Better efficiency, some electrical or duct updates $9,000 to $13,000
Premium system Variable-speed, major duct/electrical work $12,000 to $15,000+

If you are converting from a package unit (like URKA-A24)

A heat pump is usually installed as a split system (outdoor unit plus indoor air handler) or as a heat pump package unit. Converting from a gas/electric package unit can add cost for:

  • Thermostat and control wiring changes
  • Duct transitions or curb/pad modifications
  • Electrical upgrades (heat strips, breakers, wiring)
  • Refrigerant line set work (for split systems)

Why it matters

If the heat pump is undersized, it runs constantly and struggles in extreme weather; if oversized, it short-cycles and can leave humidity high. A proper load calculation is what keeps comfort and operating cost where you expect.

Parts note for URKA-A24 owners

If you are repairing the existing Ruud URKA-A24 instead of replacing the system, common fix-related parts on this model include the motor WG840465 (condenser fan motor) and the limit switch 470015 (safety temperature limit).

Last updated: February 2026

Yes, a hybrid HVAC (dual-fuel) setup is worth it when you want lower heating costs and better comfort across changing weather; it runs a heat pump in mild conditions and switches to gas heat when it is colder or when heat demand is high. For a Ruud gas/electric package unit like model URKA-A24, the value comes from matching the system to your climate, utility rates, and how often you heat.

When hybrid HVAC pays off most

  • You have long shoulder seasons (fall and spring) where a heat pump runs efficiently.
  • Electricity is relatively affordable compared to natural gas (or you have time-of-use rates).
  • You want steadier indoor temperatures with fewer big swings.
  • You plan to stay in the home long enough to recover the higher upfront cost.
  • You want redundancy; if one heat source is down, the other can often keep you comfortable.

Quick pros and cons

Factor Hybrid HVAC tends to be better Standard gas heat tends to be better
Mild-winter efficiency Heat pump mode saves energy Less benefit
Very cold weather Gas backup maintains strong heat Can still be strong, but no heat pump savings
Upfront cost Higher Lower
Complexity More components to maintain Simpler

What to check before you decide

  • Local climate: In colder regions, savings depend heavily on how often the system must rely on gas.
  • Fuel pricing: Compare your $/kWh vs $/therm and expected run time.
  • Ductwork and airflow: Heat pumps need correct airflow to perform well.
  • Repair readiness: Hybrid systems have more electrical components (controls, capacitors, motors).

Why it matters for repairs and parts

Hybrid and package systems rely on key electrical and safety parts to switch modes reliably. If you are troubleshooting hard starts, weak airflow, or heat cutouts on URKA-A24, common suspects include the condenser fan motor and run/start components such as the motor WG840465 and capacitor TRCF5.

Last updated: February 2026

Yes. Your Ruud URKA-A24 is a heater and air conditioner combo (a gas/electric package unit) that provides both cooling and heat in one outdoor cabinet, using an air conditioner section for cooling and a gas furnace section for heating.

What “combo” systems usually include

A heating and cooling combined unit typically has these major sections working together:

  • Compressor and refrigerant circuit for air conditioning
  • Condenser fan motor to move outdoor air across the coil
  • Capacitor/start components to help motors start and run
  • Gas burners and ignition/flame sensing for heat
  • Safety controls such as a limit switch

Common parts that support heating and cooling on URKA-A24

If your combo unit is not cooling, not heating, or short-cycling, these model-matched parts are commonly involved:

Symptom Cooling-side parts to check Heating-side parts to check
Outdoor unit runs but weak/no cooling Compressor, run capacitor, condenser fan motor (Not applicable)
Outdoor fan not running Motor WG840465, capacitor (Not applicable)
Hard starting, buzzing, trips breaker Start capacitor, start kit (Not applicable)
Heat starts then shuts off (Not applicable) Flame sensor, limit switch, burners

Quick checks before replacing parts

We recommend these basic checks first because they often solve “no heat” or “no cool” complaints without parts:

  • Replace or clean the air filter and make sure supply/return vents are open
  • Confirm the thermostat is set to the correct mode (HEAT vs COOL) and temperature
  • Check the outdoor cabinet for blocked airflow (leaves, lint, fencing too close)
  • Look for a tripped breaker or blown fuse in the disconnect (power off before inspecting)
  • If you suspect an electrical issue, use safe testing practices from our how to use a multimeter to test electrical parts video

Why it matters

A true combo package unit like the Ruud URKA-A24 shares airflow and controls across both heating and cooling. A single failed electrical component (like a capacitor) or safety control (like a limit switch) can stop one mode or shut the whole system down.

Last updated: February 2026

On most AC systems (including the Ruud URKA-A24 gas/electric package unit), the most common failure is a capacitor because it handles frequent start-up loads and heat stress. A weak capacitor can keep the condenser fan motor or compressor from starting, causing no cooling or hard-start symptoms.

Common failures to check first

Quick symptom-to-part guide

What you notice Most likely suspect What it affects
Humming, no start Run capacitor Fan motor or compressor start/run
Fan not spinning, compressor shuts down Condenser fan motor or run capacitor Cooling performance, head pressure
Breaker trips on start Start capacitor or start kit Compressor start-up
Heat starts then stops quickly Limit switch Furnace safety shutdown

Why this matters

A failing capacitor can make the system run hot and strain expensive components like the compressor. Catching capacitor or fan motor problems early helps prevent bigger cooling failures and reduces nuisance shutdowns.

Safety and replacement notes

  • Turn off power at the disconnect and breaker before opening panels.
  • Discharge capacitors properly; they can hold a charge after power is off.
  • Match microfarads (MFD) and voltage ratings exactly to the original part.
  • If wiring is damaged or terminals are burned, repair the wiring before installing the new part.

Last updated: February 2026

Most common symptoms to help you fix your heating & cooling combined units

Choose a symptom to see related heating and air conditioning system repairs.

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Thermostat problem, clogged air filter, burner failure…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: Errant thermostat settings, lack of power, bad interlock switches, lack of exhaust ventilation, wiring fail…

Dirty flame sensor, failed flame sensor, damaged burner, bad high limit switch…

Most common repair guides to help fix your heating & cooling combined units

These step-by-step repair guides will help you safely fix what’s broken on your HVAC system.

How to unclog the air conditioner drain line

How to unclog the air conditioner drain line

The condensate drain line for your central air conditioner can clog with mold and mildew. Water will back up and start d…

Repair time and Difficulty

 15 minutes or less
How to replace the furnace flame sensor

How to replace the furnace flame sensor

The flame sensor detects when furnace burner flames are lit. You may need to replace the flame sensor if flames only sta…

Repair time and Difficulty

 15 minutes or less
How to replace a heating and air conditioning system thermostat

How to replace a heating and air conditioning system thermostat

The control thermostat for your HVAC system can stop working. This repair guide shows how to replace it.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your heating & cooling combined units

Use the advice and tips in these articles and videos to get the most out of your HVAC system.

Should I replace my gas furnace with an electric heat pump?

Should I replace my gas furnace with an electric heat pump?

Learn the reasons why you should consider replacing a gas furnace with an electric heat pump.…

Why is my furnace not igniting?

Why is my furnace not igniting?

Find out why the burner on your furnace isn't igniting.…

Can a furnace be repaired?

Can a furnace be repaired?

Learn about furnace repairs and how much they cost.…

Parts & More

Bottom-Mount Refrigerator
Canister Vacuum
Dishwasher
Electric Range
Electric Wall Oven
Front-Engine Lawn Tractor
Gas Cooktop
Gas Range
Gas Snowblower
Parts
Side-By-Side Refrigerator
Television
Top-Mount Refrigerator
Washer