Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Goodman GMPN060-3 gas furnace

Goodman GMPN060-3 gas furnace Parts

Here are the diagrams and repair parts for Goodman GMPN060-3 gas furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for GMPN060-3 Gas Furnace

  • Blower Housing 10 X 8 (gmpn080-4) for Goodman GMPN060-3 - Part 25393-06S

    Burner box/control panel/blower diagram

    Blower Housing 10 X 8 (gmpn080-4)

    Part #25393-06S

    The manufacturer no longer makes this part, and there's no substitute part

  • Control Mount Panel for Goodman GMPN060-3 - Part 18158-17

    Burner box/control panel/blower diagram

    Control Mount Panel

    Part #18158-17

    The manufacturer no longer makes this part, and there's no substitute part

  • 17" Duct Ang for Goodman GMPN060-3 - Part 25240-01

    #NI03

    All parts diagram

    17" Duct Ang

    Part #25240-01

    The manufacturer no longer makes this part, and there's no substitute part

  • Front Panel for Goodman GMPN060-3 - Part 28301-03

    Heat exchanger diagram

    Front Panel

    Part #28301-03

    The manufacturer no longer makes this part, and there's no substitute part

  • Top Panel Downflow 14" (gmpn040-3, Gmpn060-3) for Goodman GMPN060-3 - Part 2558504P

    Cabinet diagram

    Top Panel Downflow 14" (gmpn040-3, Gmpn060-3)

    Part #2558504P

    The manufacturer no longer makes this part, and there's no substitute part

  • Flue Co Gskt for Goodman GMPN060-3 - Part B28325-01

    #NI12

    All parts diagram

    Flue Co Gskt

    Part #B28325-01

    The manufacturer no longer makes this part, and there's no substitute part

  • Gas Manifold for Goodman GMPN060-3 - Part B25260-02

    Heat exchanger diagram

    Gas Manifold

    Part #B25260-02

    The manufacturer no longer makes this part, and there's no substitute part

  • Gasket 6cell for Goodman GMPN060-3 - Part B28326-03

    Heat exchanger diagram

    Gasket 6cell

    Part #B28326-03

    The manufacturer no longer makes this part, and there's no substitute part

  • Top Panel Downflow 17.5" (gmpn080-4) for Goodman GMPN060-3 - Part 2558505P

    Cabinet diagram

    Top Panel Downflow 17.5" (gmpn080-4)

    Part #2558505P

    The manufacturer no longer makes this part, and there's no substitute part

  • 14" Duct Ang for Goodman GMPN060-3 - Part 25240-00

    #NI02

    All parts diagram

    14" Duct Ang

    Part #25240-00

    The manufacturer no longer makes this part, and there's no substitute part

Goodman Gas Furnace GMPN060-3 FAQs

Replacing a 60,000 BTU gas furnace typically costs $3,500 to $8,500 installed in the U.S., depending on efficiency level, venting changes, and labor in your area. For your Goodman GMPN060-3, confirm the exact input rating and setup details in the owner's manual.

What drives the total replacement cost

A furnace replacement price is usually a bundle of equipment plus installation work. The biggest cost swings come from:

  • Efficiency tier (AFUE): higher-efficiency units often need more complex venting and condensate handling
  • Venting and flue changes: reusing an existing vent is cheaper than reworking PVC or metal vent runs
  • Gas line and shutoff updates: may be required to meet current code and sizing needs
  • Electrical and thermostat work: new control wiring, new thermostat, or adding a common wire
  • Ductwork modifications: transitions, plenums, or correcting airflow restrictions
  • Permits and inspections: varies by location

Typical cost ranges (installed)

Replacement scenario What it usually includes Typical installed cost
Basic like-for-like swap Similar efficiency, minimal vent/duct changes $3,500 to $5,500
Mid-efficiency upgrade Some venting or duct transitions $5,000 to $7,000
High-efficiency with venting changes New PVC venting, condensate drain, more labor $6,500 to $8,500

Model-specific notes for GMPN060-3

Your furnace documentation includes procedures for rating the furnace input and timing the gas meter, which are used to confirm the unit is firing at the correct BTU rate after setup or conversion. That matters when you replace a furnace because the installer must match:

  • Input BTU (60,000 BTU class) and proper gas orifice sizing
  • Altitude requirements (the manual references adjustments above 2,000 feet)
  • Airflow and filtration (running without filters can cause nuisance limit trips)

Why it matters

A low bid can turn expensive if the new furnace needs venting, condensate drainage, or ductwork corrections to prevent short cycling, limit switch trips, and comfort problems. A properly sized and correctly vented 60,000 BTU furnace runs safer, quieter, and more efficiently.

Last updated: February 2026

A Goodman gas furnace like model GMPN060-3 typically lasts 15 to 20 years. Consistent filter changes, keeping the blower compartment clean, and correcting overheating or ignition issues quickly are the biggest factors that help you reach the high end of that range.

Typical lifespan and what affects it

Most furnaces fail early due to airflow restrictions, repeated overheating, or neglected maintenance. For a condensing gas furnace, drainage and venting condition also matter.

  • Airflow: Dirty filters or blocked returns can overheat the heat exchanger.
  • Venting and drainage: Condensing furnaces must drain properly; freezing or a clogged trap can cause shutdowns.
  • Electrical controls: Weak connections or failing boards can cause intermittent heat.
  • Burner and ignition wear: Ignitor and flame sensing issues can increase cycling.
  • Installation clearances: Tight installs make service harder and can contribute to heat buildup.

Maintenance that extends furnace life

Use the maintenance schedule and safety guidance in the owner's manual.

  • Replace or clean the air filter on a regular schedule.
  • Keep the area around the furnace clear; do not store combustibles near the cabinet.
  • Make sure the condensate drain and trap stay clear and protected from freezing.
  • Listen for blower changes (rubbing, vibration) that can signal wheel or motor issues.
  • Schedule a yearly inspection of burners, flame signal, and venting.

Quick reference: lifespan vs. what you’re seeing

What you notice Common cause What we recommend
Short cycling, frequent limit trips Overheating from low airflow Check filter, vents, blower cleanliness; verify limit switch operation
No ignition or intermittent heat Control/ignition problem Inspect wiring and ignitor circuit; test components safely
Loud blower, poor airflow Dirty or damaged blower wheel Clean blower area; replace worn blower components if needed
Water around furnace Drain or trap issue Clear trap, confirm proper routing and freeze protection

Why it matters

A furnace that is overheating or short cycling can wear out major components faster (heat exchanger, blower, controls). Addressing airflow, venting, and condensate drainage early helps your GMPN060-3 run more efficiently and last closer to 20 years.

Last updated: February 2026

On a Goodman GMPN060-3 gas furnace, code 3 (often 3 flashes) commonly points to a pressure switch problem (the switch is not proving draft). That usually means the furnace is not sensing proper venting through the inducer and vent system; use the fault chart and wiring diagram in the owner's manual to confirm the exact definition for your control.

What to check first (safe homeowner checks)

  • Replace or clean the air filter; restricted airflow can contribute to nuisance shutdowns.
  • Make sure supply registers and return grilles are open and not blocked.
  • Check the vent/intake terminations outside for snow, ice, leaves, or nests.
  • Look for a loose, cracked, or water-filled pressure switch hose.
  • If your system has condensate drainage, make sure the drain path is open and not backed up.

What the furnace is trying to verify

The pressure switch is a safety device that confirms the inducer is moving combustion gases correctly before ignition. If the switch does not close (or opens during a heat call), the control stops the ignition sequence to prevent unsafe operation.

What you observe Most likely area Typical next step
Inducer never starts Control, power, door switch Verify door is seated; check for loose wiring
Inducer runs, then code 3 Venting, pressure hose, pressure switch Clear vent restriction; inspect hose routing
Starts, then trips later Condensate/vent icing, intermittent draft Check drains and outdoor terminations

Parts that are often involved (when diagnosis confirms)

If testing shows the ignition control is not handling the sequence correctly, the model-specific replacement is the furnace hot-surface ignition control board B1809913S.

Why it matters

A pressure switch related fault is tied to combustion air and venting. Running the furnace with a venting problem risks repeated shutdowns and unsafe combustion conditions. The manual also emphasizes proper grounding and correct venting practices for reliable operation.

Last updated: February 2026

A 60,000 BTU Goodman gas furnace like model GMPN060-3 typically heats about 1,200 to 2,400 sq. ft., depending on climate, insulation, air leakage, and ductwork. For the most accurate sizing, we use a room-by-room load calculation and confirm the furnace input on the rating plate in the owner's manual.

Typical coverage range (quick guide)

Use these ranges as a practical starting point for a 60,000 BTU input furnace:

  • Warm climates / efficient homes: ~1,800 to 2,400 sq. ft.
  • Moderate climates / average insulation: ~1,400 to 2,000 sq. ft.
  • Cold climates / older or leaky homes: ~1,200 to 1,600 sq. ft.
  • High ceilings, lots of glass, or poor insulation: expect the lower end
  • Tight, well-insulated homes: expect the higher end

Why the square footage varies so much

BTU sizing is not just “house size”; it is heat loss. These factors change the required BTUs dramatically:

  • Outdoor design temperature (your winter lows)
  • Insulation levels in attic, walls, and floors
  • Window type and total window area
  • Air leakage (drafts, unsealed penetrations)
  • Duct losses (ducts in attic or crawlspace)
  • Ceiling height and open floor plans

What to check on the furnace (model GMPN060-3)

Your furnace’s actual firing rate can differ from the “60,000 BTU” you expect if gas input is off (especially after gas conversions or altitude changes). The manual includes guidance for checking input and adjusting for altitude.

  • Confirm the input BTU on the furnace rating plate
  • If installed above 2,000 ft, input is typically reduced to prevent overfiring
  • After any orifice change, input should be checked (gas meter timing method)

Minimum filter sizing (from the manual)

A restricted filter can cause overheating and nuisance limit trips, which can look like “not enough heat.” For 60,000 BTU, the manual lists this minimum filter area:

Furnace input Minimum filter area Filter type
60,000 BTU 480 / 240 sq. in. Disposable or permanent

Why it matters (right-sizing)

  • Oversized furnaces short-cycle, feel drafty, and can wear parts faster.
  • Undersized furnaces run constantly and may not maintain set temperature.

If your GMPN060-3 is short-cycling or not keeping up, common culprits include airflow issues (filter, blower wheel, duct restrictions) or ignition/control problems. For ignition-related symptoms, the furnace hot-surface ignition control board B1809913S is one of the model-specific parts used in the ignition sequence.

Last updated: February 2026

Symptoms for gas walk-behind mowers

Choose a symptom to see related walk-behind mower repairs.

Main causes: engine needs tune up, dirty or clogged carburetor, damaged flywheel key…

Main causes: stale gas, engine needs tune up, bad spark plug, dead battery, bad recoil starter, faulty safety switch, ba…

Main causes: damaged cutting blade, loose cutting blade, damaged flywheel key, engine needs tune up…

Main causes: uneven wheel height settings, damaged wheel, dull or damaged cutting blade…

Main causes: dirty carburetor, bad spark plug, clogged air filter, engine choke problems, clogged gas cap vent…

Main causes: drive control cable failure, worn or broken drive belt, bad transmission, broken drive wheel…

Repair guides for gas walk-behind mowers

These step-by-step repair guides will help you safely fix what’s broken on your walk-behind lawn mower.

How to replace a lawn mower front deck tray

How to replace a lawn mower front deck tray

Learn how to replace the front deck tray on your lawn mower if it's cracked or damaged.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower transmission

How to replace a lawn mower transmission

Learn how to replace the transmission on your lawn mower if it's locked up or won't drive the wheels.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower flywheel key on a flathead engine

How to replace a lawn mower flywheel key on a flathead engine

When you hit a hard object with your mower, the flywheel can shear to protect more expensive components. Learn how to re…

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your furnaces

Use the advice and tips in these articles and videos to get the most out of your walk-behind lawn mower.

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Band Saw
Bottom-Mount Refrigerator
Dryer
Electric Chainsaw
Elliptical Machine
Front-Engine Lawn Tractor
Gas Line Trimmer
Gas Water Heater
Grass Catcher Attachment
Household Fan
Laundry Appliance
Parts
Rolling Tool Cart
Room Air Conditioner
Table Saw
Top-Mount Refrigerator