Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
King-Craft 1705-6000W generator

King-Craft 1705-6000W generator Parts

Here are the diagrams and repair parts for King-Craft 1705-6000W generator, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 1705-6000W Generator

  • Switch Assembly for King-Craft 1705-6000W - Part APA3009-B-02-JD

    Cylinder barrell diagram

    Switch Assembly

    Part #APA3009-B-02-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt for King-Craft 1705-6000W - Part APG3009-S-17-JD

    Frame assy diagram

    Bolt

    Part #APG3009-S-17-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Flange Nut for King-Craft 1705-6000W - Part APG3009-T-09-JD

    Generator assy diagram

    Flange Nut

    Part #APG3009-T-09-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt for King-Craft 1705-6000W - Part APG3009-S-12-JD

    Frame assy diagram

    Bolt

    Part #APG3009-S-12-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Rod for King-Craft 1705-6000W - Part APG3009-M-08-JD

    Starter motor diagram

    Rod

    Part #APG3009-M-08-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw for King-Craft 1705-6000W - Part APG3009-S-05-JD

    Frame assy diagram

    Screw

    Part #APG3009-S-05-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Arm for King-Craft 1705-6000W - Part APG3009-M-11-JD

    Starter motor diagram

    Arm

    Part #APG3009-M-11-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Seal for King-Craft 1705-6000W - Part APG3009-N-04-JD

    Control assy diagram

    Seal

    Part #APG3009-N-04-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Head Cover for King-Craft 1705-6000W - Part APG3009-A-05-JD

    Cylinder head diagram

    Head Cover

    Part #APG3009-A-05-JD

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt for King-Craft 1705-6000W - Part APG3009-K-05-JD

    Ignition assy diagram

    Bolt

    Part #APG3009-K-05-JD

    The manufacturer no longer makes this part, and there's no substitute part

King-Craft Generator 1705-6000W FAQs

A 6,500-watt portable generator can power many essential circuits, but it typically will not run an entire modern home at once (especially central AC, electric heat, or an electric water heater). With a King-Craft 1705-6000W generator, plan to run selected loads and manage what’s on at the same time.

What a 6,500-watt generator can usually handle

Most homes use a mix of running watts (continuous) and starting watts (surge). A 6,500-watt class generator is usually best for essentials and a few convenience loads.

Common “essentials” you can often run (not all at once):

  • Refrigerator or freezer
  • Sump pump (if applicable)
  • Gas furnace blower (if you have gas heat)
  • A few lights and phone/laptop chargers
  • Microwave or coffee maker (one at a time)

Loads that usually prevent “whole house” operation

These loads often exceed a 6,500-watt generator by themselves or leave too little capacity for anything else:

  • Central air conditioning (high starting surge)
  • Electric furnace or baseboard heat
  • Electric water heater
  • Electric range/oven or clothes dryer
  • Well pump plus other large loads at the same time

Quick sizing check (simple method)

Use this approach to decide what you can run:

Step What to do What to watch for
1 List the circuits you want powered Focus on essentials first
2 Add running watts for those items Stay under about 80% of capacity for stability
3 Identify the biggest starting-watt load Motors and compressors surge
4 Avoid stacking surges Start one motor load at a time

Why it matters

Overloading a generator can trip breakers, cause low voltage that damages motors and electronics, and make the engine hunt or stall. Load management (what you run and when) is what makes a 6,500-watt generator work well during an outage.

Parts and help for your model

If you’re troubleshooting output issues (no power, breaker trips, unstable voltage), we recommend checking wiring connections, outlets, and protective devices, then using a meter to confirm voltage under load. You can look up parts for the King-Craft 1705-6000W and search by model on Sears PartsDirect.

Last updated: February 2026

The most common problems we see with the King-Craft 1705-6000W generator are no-start conditions, low or no AC output, and surging under load. These issues usually trace back to fuel delivery, ignition, airflow, or basic electrical protection components like breakers and fuses.

Common symptoms and what they usually mean

  • Won’t start or starts then dies: stale fuel, clogged carburetor jets, dirty air filter, fouled spark plug
  • Surges or hunts at steady load: partially clogged carburetor, vacuum leak, governor linkage out of adjustment
  • No AC power at outlets: tripped breaker, blown fuse, bad receptacle, wiring issue
  • Low voltage or weak power: overloaded generator, engine speed too low, AVR/brush issues (if equipped)
  • Runs rough or stalls when load is applied: fuel restriction, dirty carburetor, failing ignition coil

Quick checks we recommend (in order)

  1. Fuel: Drain old gas; refill with fresh fuel. Open the fuel valve (if equipped).
  2. Choke and throttle: Start with choke on, then move to run as it warms.
  3. Spark: Inspect/replace the spark plug; confirm spark.
  4. Airflow: Check the air filter and intake for blockage.
  5. Overload: Disconnect all loads; restart; then add loads one at a time.
  6. AC protection: Reset any breakers; check for a blown fuse.

Electrical troubleshooting basics

Use a meter to confirm output at the receptacle with the generator running.

What you measure Typical result What to do next
0 VAC at outlets No output Check breaker/fuse, receptacle, wiring; then AVR/brushes if equipped
Low VAC (below normal) Weak output Reduce load; verify engine speed/governor; inspect alternator components
Normal VAC, but tools still fail Load issue Check extension cord, plug, and appliance load requirements

For safe meter technique and interpreting readings, use how to use a multimeter to test electrical parts video. For fuse diagnosis, use how to tell if a fuse is blown.

Why it matters

A 6000W-class generator like the 1705-6000W is sensitive to fuel quality and load. Fixing a simple fuel restriction or a tripped breaker prevents repeated no-starts, unstable voltage, and damage to connected equipment.

Last updated: March 2026

The most common reason a King-Craft generator like model 1705-6000W will not start is fuel-related, especially old gasoline that gums up the carburetor and prevents the engine from getting the right fuel mixture. A fouled spark plug is another frequent, quick-to-fix cause.

Quick checks that solve most no-start problems

  • Fuel freshness: Drain old fuel and refill with fresh gasoline.
  • Fuel valve and choke: Confirm the fuel valve is ON; use choke for cold starts, then open it as the engine warms.
  • Spark plug condition: Remove and inspect; clean or replace if fouled, wet, or heavily carboned.
  • Air filter: Check for a clogged or oil-soaked filter that can choke airflow.
  • Low-oil shutdown (if equipped): Verify oil level is at the full mark; many generators will not start when oil is low.
  • On/Off switch and breaker: Make sure the engine switch is ON and the output breaker is reset.

Most-likely causes and what they look like

Symptom Most likely cause What to do first
Starts briefly, then dies Carburetor varnish from old fuel Drain fuel; clean carburetor bowl and jets
Cranks but never fires No spark or no fuel Check spark plug; confirm fuel flow
Strong fuel smell, plug wet Flooded engine Open choke; pull-start a few times; dry/replace plug
Pull rope is very hard to pull Possible engine/mechanical issue Stop and inspect for binding before forcing

Why it matters

Old fuel can leave residue that restricts tiny carburetor passages, so even a small amount of varnish can prevent starting. Keeping the fuel system clean and the ignition parts (like the spark plug) in good shape prevents most “won’t start” complaints.

Parts and repair help

If you need replacement parts for your King-Craft 1705-6000W generator, start with the parts list for this model, or search by model number on Sears PartsDirect. For safe electrical troubleshooting steps, we also recommend how to use a multimeter to test electrical parts video.

Last updated: February 2026

Symptoms for top-mount refrigerators

Main causes: frozen or clogged defrost drain tube, cracked water system tubing…

Repair guides for top-mount refrigerators

How to replace the light switch in a top-freezer refrigerator

How to replace the light switch in a top-freezer refrigerator

The light switch turns the refrigerator light on and off and monitors door position. Replace the light switch if it does…

Repair time and Difficulty

 15 minutes or less
How to replace the water inlet valve in a top-freezer refrigerator

How to replace the water inlet valve in a top-freezer refrigerator

The water inlet valve controls water flow to the ice maker. Replace the water valve if it doesn't open or shut properly.…

Repair time and Difficulty

 15 minutes or less
How to replace the compressor run capacitor in a top-freezer refrigerator

How to replace the compressor run capacitor in a top-freezer refrigerator

The run capacitor sends electric current to the compressor motor to help the motor run efficiently. Replace the run capa…

Repair time and Difficulty

 15 minutes or less

Articles and videos for top-mount refrigerators

How to enjoy all the online benefits we offer on our Sears PartsDirect website

How to enjoy all the online benefits we offer on our Sears PartsDirect website

Learn about all the convenient features on our Sears PartsDirect website that make your parts purchases easier.…

Tapping into a new feature in the Search Bar on Sears PartsDirect

Tapping into a new feature in the Search Bar on Sears PartsDirect

Learn about a new feature added to the Search Bar on Sears PartsDirect…

Parts & More

Bench Grinder
Countertop Microwave
Dishwasher
Dryer
Front-Engine Lawn Tractor
Gas Leaf Blower
Gas Range
Gas Snowblower
Gas Walk-Behind Mower
Hole Digger
Lawn & Garden Engine
Log Splitter
Parts
Side-By-Side Refrigerator
Washer