Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Coleman Evcon BRCS0301CB central air conditioner

Coleman Evcon BRCS0301CB central air conditioner Parts

Here are the diagrams and repair parts for Coleman Evcon BRCS0301CB central air conditioner, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for BRCS0301CB Central Air Conditioner

  • Compressor (60) (copeland Zr57kc-tf5) for Coleman Evcon BRCS0301CB - Part 1450-511P

    Functional replacement parts diagram

    Compressor (60) (copeland Zr57kc-tf5)

    Part #1450-511P

    The manufacturer no longer makes this part, and there's no substitute part

  • Dual Capacitor 35/5 Mfd (361cb, 42) for Coleman Evcon BRCS0301CB - Part 1498-5361

    Functional replacement parts diagram

    Dual Capacitor 35/5 Mfd (361cb, 42)

    Part #1498-5361

    The manufacturer no longer makes this part, and there's no substitute part

  • Guard for Coleman Evcon BRCS0301CB - Part 2660-3351

    Functional replacement parts diagram

    Guard

    Part #2660-3351

    The manufacturer no longer makes this part, and there's no substitute part

  • Drier for Coleman Evcon BRCS0301CB - Part 1458-0501

    Functional replacement parts diagram

    Drier

    Part #1458-0501

    The manufacturer no longer makes this part, and there's no substitute part

  • Outdoor Coil Assembly (30) for Coleman Evcon BRCS0301CB - Part 6903-4501

    Functional replacement parts diagram

    Outdoor Coil Assembly (30)

    Part #6903-4501

    The manufacturer no longer makes this part, and there's no substitute part

  • Compressor (48) (bristol H23a564abca) for Coleman Evcon BRCS0301CB - Part 1450-509P/A

    Functional replacement parts diagram

    Compressor (48) (bristol H23a564abca)

    Part #1450-509P/A

    The manufacturer no longer makes this part, and there's no substitute part

  • Guard for Coleman Evcon BRCS0301CB - Part 2218-3371/A

    Functional replacement parts diagram

    Guard

    Part #2218-3371/A

    The manufacturer no longer makes this part, and there's no substitute part

  • Cover-box for Coleman Evcon BRCS0301CB - Part 2218-1151

    Functional replacement parts diagram

    Cover-box

    Part #2218-1151

    The manufacturer no longer makes this part, and there's no substitute part

  • Coil Guard Long (18, 24, 301cb) for Coleman Evcon BRCS0301CB - Part 2218-3351

    Functional replacement parts diagram

    Coil Guard Long (18, 24, 301cb)

    Part #2218-3351

    The manufacturer no longer makes this part, and there's no substitute part

  • Compressor for Coleman Evcon BRCS0301CB - Part 1450-306P

    Functional replacement parts diagram

    Compressor

    Part #1450-306P

    The manufacturer no longer makes this part, and there's no substitute part

Coleman Evcon Central Air Conditioner BRCS0301CB FAQs

For the Coleman BRCS0301CB Evcon central air conditioner, the most commonly replaced parts are the electrical start components and airflow components (like capacitors, contactors, and fan motors), plus wear items in the control and power circuit. These parts fail more often than the sealed refrigerant system.

Most common replacement parts (and what they do)
  • Run capacitor / start capacitor: helps the compressor and fan motor start and run.
  • Contactor (relay): switches high voltage to the outdoor unit when the thermostat calls for cooling.
  • Condenser fan motor: moves air through the outdoor coil to reject heat.
  • Fan blade: can crack, loosen, or get out of balance and damage the motor.
  • Transformer / low-voltage components: supports the 24-volt control circuit.
  • Fuses / disconnect components: protect the circuit from shorts and overloads.
Less common, but higher-impact repairs

These parts are replaced less often, but they are bigger repairs when they fail.

Part/system How often it’s replaced Why it’s a bigger deal
Compressor Less common Major labor and refrigerant handling required
Indoor evaporator coil Less common Can involve refrigerant work and system cleanup
Outdoor condenser coil Less common Often tied to corrosion or physical damage
Refrigerant (leak repair) As needed Requires leak finding, repair, evacuation, and recharge
Quick checks before you buy parts

Turn off power at the disconnect and breaker before opening any panels.

  • Confirm the thermostat is calling for cooling and the indoor blower is running.
  • If the outdoor unit hums but won’t start, suspect a capacitor first.
  • If nothing outside runs (no hum), suspect the contactor, fuse, or low-voltage power.
  • If the fan runs but there’s no cooling, check for a dirty coil, restricted airflow, or a refrigerant issue.
  • If you’re testing electrical parts, use a meter and follow safe procedures.
Why it matters

Replacing common electrical and airflow parts early can prevent repeat shutdowns, overheating, and secondary damage to the compressor. It also helps restore normal cooling performance and efficiency.

For help identifying the correct replacement parts by model number, use how to find your appliance model number (and what it means for parts).

Last updated: February 2026

A new central air conditioner typically costs about $5,000 to $12,000 installed for most homes; higher-efficiency systems, larger tonnage, and ductwork or electrical upgrades can push the total higher. For a Coleman Evcon central air conditioner like model BRCS0301CB, the installed price depends mainly on capacity, SEER2 rating, and installation complexity.

Typical price ranges (what you’re paying for)
  • Equipment only (outdoor condenser plus indoor coil): often $2,500 to $7,500
  • Installed total (most common): often $5,000 to $12,000
  • Higher-end installs: often $12,000 to $18,000+ (high SEER2, zoning, major duct changes)
What changes the price the most
  • System size (tonnage): bigger homes need larger capacity
  • Efficiency (SEER2): higher SEER2 usually costs more up front
  • Ductwork condition: leaks, undersized returns, or no existing ducts add cost
  • Electrical and pad work: disconnect, breaker, wiring, and condenser pad
  • Refrigerant line set: replacement or flushing when changing systems
  • Permits and labor rates: vary by region and season
Quick cost checklist before you buy
Cost comparison table
Scenario What’s included Typical installed total
Basic replacement Like-for-like swap, existing ducts OK $5,000 to $9,000
Mid-range upgrade Better SEER2, some electrical or line set work $8,000 to $12,000
Complex install Ductwork changes, zoning, major upgrades $12,000 to $18,000+
Why it matters

Central AC pricing is driven as much by installation scope as by the condenser itself. Getting the right capacity and airflow protects comfort, humidity control, and compressor life, which is especially important for long-term reliability.

Last updated: February 2026

Most central air conditioning units last 15 to 20 years with normal use and regular maintenance. For a Coleman Evcon central air conditioner like model BRCS0301CB, reaching the upper end of that range depends on keeping airflow clean, electrical connections tight, and the refrigerant system leak-free.

Typical lifespan ranges (what to expect)
  • 15 to 20 years: Most modern central AC systems
  • 10 to 12 years: Units with heavy run time, poor maintenance, or harsh conditions
  • 20+ years: Possible with excellent maintenance and mild operating conditions
Condition What it usually does to lifespan Example
Regular maintenance Extends life Clean coils, change filters, clear debris
Restricted airflow Shortens life Dirty filter, blocked return vents
Electrical wear Shortens life Weak capacitor, pitted contactor
Refrigerant leaks Shortens life Low charge causing long run times
Signs your central AC is near end of life
  • Cooling takes longer than it used to (long run times)
  • Frequent service calls for electrical or refrigerant issues
  • Outdoor unit is louder than normal (fan motor or compressor strain)
  • Rising energy bills with no change in thermostat settings
  • Uneven cooling from room to room (airflow or duct issues)
Maintenance that most improves longevity
  • Replace or clean the air filter on schedule (often every 1 to 3 months)
  • Keep the outdoor condenser coil clear (leaves, grass clippings, lint)
  • Maintain at least 2 feet of clearance around the outdoor unit
  • Verify the indoor blower and evaporator coil stay clean
  • Have a technician check refrigerant charge and electrical components seasonally
Why it matters

A central air conditioner that is maintained well runs cooler, cycles normally, and puts less stress on the compressor. That directly affects comfort, energy use, and how long your BRCS0301CB system stays reliable.

For general DIY safety and planning before any electrical checks, we recommend reviewing are diy appliance repairs safe.

Last updated: February 2026

Symptoms for top-mount refrigerators

Main causes: frozen or clogged defrost drain tube, cracked water system tubing…

Repair guides for top-mount refrigerators

How to replace the light switch in a top-freezer refrigerator

How to replace the light switch in a top-freezer refrigerator

The light switch turns the refrigerator light on and off and monitors door position. Replace the light switch if it does…

Repair time and Difficulty

 15 minutes or less
How to replace the water inlet valve in a top-freezer refrigerator

How to replace the water inlet valve in a top-freezer refrigerator

The water inlet valve controls water flow to the ice maker. Replace the water valve if it doesn't open or shut properly.…

Repair time and Difficulty

 15 minutes or less
How to replace the compressor run capacitor in a top-freezer refrigerator

How to replace the compressor run capacitor in a top-freezer refrigerator

The run capacitor sends electric current to the compressor motor to help the motor run efficiently. Replace the run capa…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your central air conditioners

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Bottom-Mount Refrigerator
Cooktop
Dishwasher
Dryer
Electric Chainsaw
Electric Leaf Blower
Electric Water Heater
Electronic Sewing Machine
Front-Engine Lawn Tractor
Furnace
Gas Range
Line Trimmer
Parts
Refrigerator
Table Saw
Top-Mount Refrigerator
Walk-Behind Mower
Washer