Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Carrier FV4BNB006000 fan coil

Carrier FV4BNB006000 fan coil Parts

Here are the diagrams and repair parts for Carrier FV4BNB006000 fan coil, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for FV4BNB006000 Fan Coil

  • Panel Assembly for Carrier FV4BNB006000 - Part 328148-704

    Casing assy diagram

    Panel Assembly

    Part #328148-704

    The manufacturer no longer makes this part, and there's no substitute part

  • Support for Carrier FV4BNB006000 - Part 314958-401

    Blower assy diagram

    Support

    Part #314958-401

    The manufacturer no longer makes this part, and there's no substitute part

  • 149,heater Asy for Carrier FV4BNB006000 - Part 324633-702

    Casing assy diagram

    149,heater Asy

    Part #324633-702

    The manufacturer no longer makes this part, and there's no substitute part

  • Fuse for Carrier FV4BNB006000 - Part ATC5

    Casing assy diagram

    Fuse

    Part #ATC5

    The manufacturer no longer makes this part, and there's no substitute part

  • 109,heater Asy 15kw N/fu for Carrier FV4BNB006000 - Part 324637-701

    Casing assy diagram

    109,heater Asy 15kw N/fu

    Part #324637-701

    The manufacturer no longer makes this part, and there's no substitute part

  • Connector for Carrier FV4BNB006000 - Part HY90AZ021

    Casing assy diagram

    Connector

    Part #HY90AZ021

    The manufacturer no longer makes this part, and there's no substitute part

  • 110,heater Assy for Carrier FV4BNB006000 - Part 324630-701

    Casing assy diagram

    110,heater Assy

    Part #324630-701

    The manufacturer no longer makes this part, and there's no substitute part

Carrier Fan Coil FV4BNB006000 FAQs

A 4-ton air handler is typically set up to move about 1,400 to 1,600 CFM (cubic feet per minute), depending on the comfort/efficiency mode and airflow tap settings. For the Carrier FV4BNB006000 fan coil, the exact target CFM depends on the Easy Select airflow settings in the installation guide.

Typical CFM for 4 tons (what we use in the field)

Most systems are designed around these common airflow targets:

  • 350 CFM per ton: good humidity removal in cooling
  • 400 CFM per ton: common “rule of thumb” cooling airflow
  • 315 CFM per ton (heating comfort mode): warmer supply air feel in heat pump heating

That translates to this for 4 tons:

Airflow target CFM per ton 4-ton total CFM
Heat pump comfort heating 315 1,260
Heat pump efficiency (heat/cool match) 350 1,400
Typical cooling rule of thumb 400 1,600

What changes the CFM on the Carrier FV4BNB006000

This model uses selectable airflow profiles (system type and airflow adjust). The installation instructions describe:

  • System type selection (AC vs. heat pump modes)
  • Heat pump comfort vs. efficiency airflow profiles
  • AC/HP CFM adjust settings (nominal, high, low)
  • Dehumidification mode that can run at about 80% of nominal cooling airflow
  • Static pressure and ductwork effects (dirty filter, restrictive returns, undersized ducts)

Quick way to estimate your current setting

We use this simple math to sanity-check airflow before measuring:

  • CFM = tons × target CFM/ton
  • Example: 4 × 350 = 1,400 CFM
  • Example: 4 × 400 = 1,600 CFM

Why it matters

Airflow that is too low can cause coil icing, poor comfort, and longer run times; airflow that is too high can reduce dehumidification and feel drafty. Setting the correct CFM helps your Carrier fan coil match the outdoor unit capacity and deliver stable heating and cooling.

Parts that can affect airflow

If airflow is inconsistent, the control setup and blower operation matter. A common control-related replacement on this model is the board circ HK61EA005. For ordering model-correct parts, we list them on the model parts list and on Sears PartsDirect.

Last updated: February 2026

Most air handlers (fan coils) cost $1,000 to $4,200 for the unit and $1,800 to $3,500+ installed. For a Carrier FV4BNB006000, the biggest price drivers are capacity (tonnage), blower type (ECM/variable speed vs. standard), and installation complexity; details in the installation guide can affect labor time.

What drives the price up or down

  • Capacity and airflow requirements (larger systems cost more)
  • Blower motor type (ECM/variable speed typically costs more)
  • Electric heat kit (adds parts cost and electrical labor)
  • Ductwork, drain, or return-air changes (common add-ons)
  • Controls and electronics (boards/modules can be a major expense)
  • Access and location (attic, tight closet, or difficult service access)

Typical cost breakdown

Cost item Typical range What it includes
Air handler unit $1,000 to $4,200 Equipment only (varies by size and features)
Labor and materials $800 to $2,000+ Set-up, fittings, drain work, electrical, start-up checks
Total installed $1,800 to $3,500+ Higher with major duct/electrical modifications

FV4BNB006000 setup items that can affect labor

Your FV4B-series air handler can require commissioning steps that add time, such as:

  • Selecting system type (AC vs. heat pump)
  • Setting AC/HP CFM adjust (NOM, HI at +15% airflow, LO at -10% airflow)
  • Confirming airflow targets using CFM tables

Those configuration steps are covered in the installation guide.

Repair vs. replace: a quick way to think about it

If the issue is mainly... Typical direction
Airflow setup, wiring, loose connections Repair/adjust first
Major electronics failure Compare repair cost to replacement
Multiple age-related problems Replacement often makes more sense

Why it matters

Correct sizing and airflow setup improve comfort, humidity control, and efficiency. Paying for proper installation helps prevent noise, poor cooling, and premature wear on the blower and control components.

For broader part and model lookups beyond the parts list for FV4BNB006000, use Sears PartsDirect.

Last updated: February 2026

If your Carrier FV4BNB006000 fan coil has weak airflow, short cycling, unusual noises, or inconsistent heating and cooling, the air handler (or a control, wiring, or blower component inside it) is failing. Use the diagnostic steps in the installation guide to separate a true air handler failure from a thermostat or wiring issue.

Quick signs the air handler is failing

  • Weak or uneven airflow from supply vents
  • Frequent on and off cycling (short cycling)
  • No heat or no cool air even when the outdoor unit is running
  • Musty odors near the return or air handler cabinet
  • New rattling, buzzing, or humming from the blower area
  • Higher energy use with no thermostat changes

Checks to do before replacing parts

Disconnect power before removing panels.

  • Air filter and return airflow: A clogged filter is the most common cause of low airflow and coil icing.
  • Drain pan and condensate drain: Blockages can cause water issues and can stop operation.
  • Thermostat call and wiring: If the blower runs in some calls but not others, focus on wiring, harness connections, and control signals.
  • ECM blower motor system: FV4BNB006000 uses an ECM motor with a control module and motor winding section; a no-start condition can be caused by control signals, not just a bad motor.

What the symptoms usually point to

What you observe Most likely area to check Typical next step
Blower never runs Power, board, harness, ECM module Verify signals and connections per guide
Blower runs in some modes only Harness or control board Inspect plugs, pins, and board outputs
Correct signals present but no blower ECM module or motor winding Test motor winding resistance

If testing points to a failed control board, the board circ HK61EA005 is the listed control board for this model.

Why it matters

“Bad air handler” symptoms often come from a simple restriction (filter) or an electrical issue (harness, board, ECM module). Isolating the cause prevents unnecessary part replacement and restores proper airflow.

You can order parts from the model parts list, or search by model number on Sears PartsDirect.

Last updated: February 2026

For the Carrier FV4BNB006000 fan coil (air handler), we tell tonnage by identifying the system size the unit is set up for and confirming it with airflow targets. The setup tables use CFM-per-ton guidance (about 315 to 350 CFM per ton); see the installation guide.

Fast ways to identify tonnage

  • Check the unit nameplate and the matched outdoor condenser or heat pump rating (BTU/hr); 12,000 BTU/hr equals 1 ton.
  • Verify the AC/HP size selection on the control board; the guide instructs selecting the installed system size so airflow stays in range.
  • Use airflow as a confirmation: measured CFM divided by about 350 CFM per ton estimates nominal tons.
  • Compare your measured airflow to the airflow tables by unit size and mode in the guide.

Airflow-to-tonnage cheat sheet (rule of thumb)

Airflow (approx.) Estimated tons (at ~350 CFM/ton)
700 CFM 2 tons
1050 CFM 3 tons
1400 CFM 4 tons
1750 CFM 5 tons

What settings affect the “effective” tonnage

These selections change delivered airflow and comfort performance:

  • System type (AC vs. heat pump comfort vs. heat pump efficiency)
  • AC/HP size selection (installed system size)
  • AC/HP CFM adjust (NOM, HI, LO; HI is about +15%, LO is about -10%)

Why it matters

Correct tonnage and airflow protect comfort and equipment; too much airflow can reduce humidity removal, and too little airflow can contribute to coil icing and poor cooling.

If airflow seems wrong after verifying settings and wiring, the control board can be involved; this model lists the board circ HK61EA005. You can also search more parts by model on Sears PartsDirect.

Last updated: February 2026

Symptoms for gas walk-behind mowers

Choose a symptom to see related walk-behind mower repairs.

Main causes: engine needs tune up, dirty or clogged carburetor, damaged flywheel key…

Main causes: stale gas, engine needs tune up, bad spark plug, dead battery, bad recoil starter, faulty safety switch, ba…

Main causes: damaged cutting blade, loose cutting blade, damaged flywheel key, engine needs tune up…

Main causes: uneven wheel height settings, damaged wheel, dull or damaged cutting blade…

Main causes: dirty carburetor, bad spark plug, clogged air filter, engine choke problems, clogged gas cap vent…

Main causes: drive control cable failure, worn or broken drive belt, bad transmission, broken drive wheel…

Repair guides for gas walk-behind mowers

These step-by-step repair guides will help you safely fix what’s broken on your walk-behind lawn mower.

How to replace a lawn mower front deck tray

How to replace a lawn mower front deck tray

Learn how to replace the front deck tray on your lawn mower if it's cracked or damaged.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower transmission

How to replace a lawn mower transmission

Learn how to replace the transmission on your lawn mower if it's locked up or won't drive the wheels.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower flywheel key on a flathead engine

How to replace a lawn mower flywheel key on a flathead engine

When you hit a hard object with your mower, the flywheel can shear to protect more expensive components. Learn how to re…

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your air handlers

Use the advice and tips in these articles and videos to get the most out of your walk-behind lawn mower.

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Parts & More

Countertop Microwave
Dryer
Electric Range
Fitness & Exercise
Gas Pressure Washer
Lawn Edger
Miter Saw
Parts
Rear-Engine Riding Mower
Side-By-Side Refrigerator
Top-Mount Refrigerator
Vhs Players & Vcrs