Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
ICP NAC042AKA1 condensing unit

ICP NAC042AKA1 condensing unit Parts

Here are the diagrams and repair parts for ICP NAC042AKA1 condensing unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for NAC042AKA1 Condensing Unit

  • Icp Condenser for ICP NAC042AKA1 - Part 1088111

    Condensing unit diagram

    Icp Condenser

    In Stock
    $2889.36
    Minus Item
    Qty
    Plus Item
  • Cond.motor for ICP NAC042AKA1 - Part 1086486

    Condensing unit diagram

    Cond.motor

    In Stock
    $503.32
    Minus Item
    Qty
    Plus Item
  • Central Air Conditioner Condenser Fan Blade for ICP NAC042AKA1 - Part 1085958

    Condensing unit diagram

    Central Air Conditioner Condenser Fan Blade

    In Stock
    $172.68
    6% OFF Phone Price : $184.68Info Icon
    Minus Item
    Qty
    Plus Item
  • Valve for ICP NAC042AKA1 - Part 1085989

    Condensing unit diagram

    Valve

    In Stock
    $132.96
    Minus Item
    Qty
    Plus Item
  • Compressor for ICP NAC042AKA1 - Part 1082719

    Condensing unit diagram

    Compressor

    In Stock
    $40.80
    Minus Item
    Qty
    Plus Item
  • Contactor for ICP NAC042AKA1 - Part 1050839

    Condensing unit diagram

    Contactor

    In Stock
    $194.69
    Minus Item
    Qty
    Plus Item
  • Capacitor for ICP NAC042AKA1 - Part 1172095

    Condensing unit diagram

    Cap Rn Rp

    Part #1086680

    Replaced by #1172095

    Info Icon
    Manufacturer substitution
    This part replaces 1086680. Substitute parts can look different from the original.
    In Stock
    $110.14
    Minus Item
    Qty
    Plus Item
  • Central Air Conditioner Compressor Wire Harness for ICP NAC042AKA1 - Part 1083654

    Condensing unit diagram

    Plug Wire

    Part #1081939

    Replaced by #1083654

    Info Icon
    Manufacturer substitution
    This part replaces 1081939. Substitute parts can look different from the original.
    In Stock
    $81.07
    7% OFF Phone Price : $87.07Info Icon
    Minus Item
    Qty
    Plus Item
  • Icp Condenser for ICP NAC042AKA1 - Part 1088111

    Condensing unit diagram

    Condenser

    Part #1086136

    Replaced by #1088111

    Info Icon
    Manufacturer substitution
    This part replaces 1086136. Substitute parts can look different from the original.
    In Stock
    $2889.36
    Minus Item
    Qty
    Plus Item
  • Base Panel for ICP NAC042AKA1 - Part 1085982

    Condensing unit diagram

    Base Panel

    Part #1085982

    The manufacturer no longer makes this part, and there's no substitute part

ICP Condensing Unit NAC042AKA1 FAQs

Most central air conditioning units last 15 to 20 years with proper installation, correct refrigerant charge, and regular maintenance. For your Icp NAC042AKA1 condensing unit, annual service and keeping records also matters because many warranties require proof of maintenance; see the owner's manual.

Typical lifespan ranges (what we see most often)

  • 15 to 20 years: Most modern central AC systems in normal residential use
  • 10 to 12 years: Units in harsh conditions (coastal air, heavy runtime, poor airflow)
  • 20+ years: Well-maintained systems with clean coils, correct airflow, and stable electrical supply

What shortens or extends AC life

A central air conditioner is a system (outdoor condensing unit plus indoor coil and blower). These factors have the biggest impact:

  • Maintenance quality: Dirty condenser coils and clogged indoor airflow reduce efficiency and stress the compressor
  • Electrical wear: Pitted contactor points and weak capacitors cause hard starts and overheating
  • Airflow problems: Dirty filters, blocked returns, or duct restrictions can freeze the coil and flood refrigerant back to the compressor
  • Oversizing/short cycling: Frequent starts are harder on motors and controls
  • Environment: Cottonwood, grass clippings, dryer vents, and salt air accelerate corrosion and clogging

Quick maintenance checklist (high impact)

  • Replace/clean the indoor air filter on schedule
  • Keep 2 feet of clearance around the outdoor unit; rinse debris off the coil (power off first)
  • Confirm the condenser fan runs smoothly and is not wobbling
  • Have a technician verify refrigerant charge and temperature split
  • Inspect electrical components like the contactor and capacitor for overheating or bulging

Common wear parts and what they affect

Part What it does When it can shorten lifespan
Contactor Switches power to the compressor/fan Chattering or burned contacts cause voltage drop and heat
Capacitor Helps motors start and run Weak capacitance causes hard starts and overheating
Condenser fan blade Moves air through the outdoor coil Poor airflow raises head pressure and compressor stress

Why it matters

A unit near the end of its typical lifespan is more likely to have expensive failures (compressor, fan motor, electrical controls). Catching airflow and electrical issues early often adds years of reliable cooling.

You can order model-specific replacement parts for NAC042AKA1, such as the central air conditioner condenser fan blade 1085958, from the parts list for this model, or search by model number on Sears PartsDirect.

Last updated: February 2026

The Icp NAC042AKA1 central air conditioner condensing unit is a 3.5-ton system (about 42,000 BTU/hr of cooling capacity). Confirm the exact rated capacity for your specific installation and matched indoor coil in the installation guide.

How we interpret “tonnage” for this model

Tonnage is the nominal cooling capacity of the outdoor condensing unit.

  • 1 ton = 12,000 BTU/hr
  • 3.5 tons = 42,000 BTU/hr
  • Model numbers that include “042” commonly indicate ~42,000 BTU/hr capacity

Quick capacity reference

Nominal tonnage Approx. BTU/hr Typical use
3.0 ton 36,000 Medium homes, moderate loads
3.5 ton 42,000 Larger loads, higher heat gain
4.0 ton 48,000 Larger homes, heavier loads

Why matched components matter

Your NAC042AKA1’s real-world performance depends on the full system match (outdoor unit, indoor evaporator coil, metering device, and airflow). A mismatch can reduce capacity, efficiency, and reliability.

  • Verify the indoor coil tonnage matches the outdoor unit
  • Confirm blower airflow is set correctly (commonly around 350 to 450 CFM per ton)
  • Keep the condenser coil clean and the outdoor fan moving proper air
  • If the outdoor fan is damaged or out of balance, replace it with the correct central air conditioner condenser fan blade 1085958

If you are ordering parts for NAC042AKA1

Use the parts list for NAC042AKA1 to match by model and diagram; for broader model searches and ordering, use Sears PartsDirect.

Last updated: February 2026

Replacing a central AC system like the Icp NAC042AKA1 condensing unit typically runs $6,500 to $12,000 installed for many homes; total cost goes up or down based on system size (tonnage), efficiency, ductwork condition, and electrical or refrigerant-line work. Use the NAC042AKA1 installation guide to understand what a correct installation includes.

What drives the price the most

  • Tonnage and sizing: Larger homes and higher cooling loads require larger equipment.
  • Efficiency level: Higher-efficiency systems usually cost more upfront.
  • Ductwork: Leaky, undersized, or damaged ducts can add significant labor and materials.
  • Electrical upgrades: Disconnect, breaker, wiring, or service changes can add cost.
  • Refrigerant line set work: Reusing vs. replacing lines, flushing, and brazing quality matter.
  • Access and labor complexity: Tight pads, landscaping, long runs, or attic/crawlspace work.

Typical replacement cost ranges (installed)

Scenario What’s included Common total range
Like-for-like condenser swap Outdoor unit plus basic startup $4,500 to $8,500
Full central AC replacement Outdoor unit + indoor coil, more labor $6,500 to $12,000
Complex install Duct repairs, electrical work, access issues $10,000 to $16,000+

Repair vs. replace: a practical way to decide

If your NAC042AKA1 is cooling poorly, it can be smarter to price a repair first when the issue is a common wear part.

  • If the outdoor fan is noisy or wobbling, check the condenser fan blade and motor condition; see central air conditioner condenser fan blade 1085958.
  • If the outdoor unit will not start, a failed contactor or capacitor is common.
  • If wiring is brittle or damaged, address it before replacing major components.

Why it matters

A central AC replacement quote is not just “the box outside.” Correct sizing, airflow, electrical safety, and refrigerant practices determine comfort, efficiency, and reliability. The warranty language also typically expects proper installation and ongoing maintenance; see the NAC042AKA1 owner’s manual for maintenance expectations.

For parts pricing and model-specific components, order from the parts list for NAC042AKA1 or search by model on Sears PartsDirect.

Last updated: February 2026

On most central AC systems, the compressor is typically the most expensive component to replace because it is the heart of the refrigerant system and the repair usually involves refrigerant recovery, sealed-system work, and significant labor. For your Icp NAC042AKA1 condensing unit, compressor-related repairs are commonly the top-cost scenario.

Why the compressor is usually the costliest

The compressor does the heavy lifting in the cooling cycle, and replacing it often requires specialized tools and procedures (electrical testing, brazing, evacuation, and recharging). That combination of part cost + labor is what drives the total price up.

Common reasons compressor replacement gets expensive:

  • Sealed-system labor (refrigerant handling and leak checks)
  • Electrical diagnosis (contactor, capacitor, wiring)
  • Potential related damage (overheating, contamination)
  • Time on site and required test equipment

Other high-cost AC parts (and when they compete)

Depending on the failure and system design, these can also be expensive:

  • Condenser coil (outdoor coil) replacement
  • Evaporator coil (indoor coil) replacement
  • Major electrical/control failures (control board, transformer)

The Icp warranty language also lists many “functional component parts” that can be involved in major repairs, including the evaporator coil, condenser coil, condenser fan, capacitor, relays and contactors. Checking coverage details in your paperwork can help you understand what is parts-only versus labor. See the NAC042AKA1 owner's manual.

Quick cost comparison (typical)

Component Why it can be expensive Typical cost driver
Compressor Sealed-system repair complexity Labor + refrigerant work
Evaporator coil Access and refrigerant work Labor + coil cost
Condenser coil Outdoor coil replacement Coil cost + labor
Control board/controls Diagnostics and part pricing Part cost

Why it matters

If the compressor is failing, we recommend confirming airflow and electrical health first because less expensive parts can cause compressor symptoms. On this model, common supporting parts include a contactor and capacitor; if those are weak, the compressor may not start or may overheat.

Helpful checks before committing to a major repair:

  • Verify the outdoor fan runs and the coil is clean
  • Test capacitor values and contactor operation
  • Inspect wiring for heat damage or loose connections
  • Compare repair cost versus unit age and condition

For replacement parts for Icp NAC042AKA1, use the parts list for your model or search by model number on Sears PartsDirect.

Last updated: February 2026

On most central AC condensing units like the Icp NAC042AKA1, the run capacitor is the most common part to fail because it handles frequent starts and heat stress. When it weakens, the outdoor fan or compressor may hum, struggle to start, or shut off on overload; confirm specs and wiring in the NAC042AKA1 installation guide.

What you’ll usually notice when a capacitor is failing

  • Outdoor unit hums but the condenser fan does not spin
  • Fan starts only after a push (if it is not seized)
  • Compressor tries to start, then clicks off
  • Intermittent cooling, especially on hot afternoons
  • Bulged or leaking capacitor (visual sign after power is off)

Other common failure parts on a condensing unit

Capacitors fail often, but these parts also cause frequent “won’t run” or “no cooling” complaints:

Part What it does Common symptom when it fails
Run capacitor Helps start and run the fan and compressor Humming, hard starts, trips breaker
Contactor Switches high voltage to the compressor/fan Outdoor unit will not start
Condenser fan blade Moves air across the outdoor coil Overheating, poor cooling, loud vibration
Wiring/terminals Carries power and control signals Burnt connections, intermittent operation

Parts we commonly replace for NAC042AKA1

If your symptoms point to a start/run issue, these model-matched parts are common fixes:

Why it matters

A weak capacitor can make the compressor and fan motor draw higher amperage and overheat. Replacing the failing electrical part early helps prevent repeat shutdowns and protects expensive components.

Safety note before troubleshooting

High voltage is present in the outdoor unit. We follow the Electrical Shock Hazard guidance in the NAC042AKA1 installation guide and shut off power at the disconnect and breaker before opening the control box.

You can order replacement parts for your NAC042AKA1 from the parts list for this model, or search by model number on Sears PartsDirect.

Last updated: February 2026

Symptoms for gas ranges

Main causes: gas supply problem, faulty pressure regulator, clogs in burner or orifice, control system failure, faulty t…

Main causes: burner igniter switch failure, bad spark module, dirty or damaged spark electrode, wiring failure…

Repair guides for gas ranges

How to replace a gas range oven igniter

How to replace a gas range oven igniter

If your gas oven doesn't heat up, the problem could be a faulty oven igniter. These step-by-step instructions guide you …

Repair time and Difficulty

 45 minutes or less
How to replace an oven temperature sensor on a gas range

How to replace an oven temperature sensor on a gas range

See how to replace an oven temperature sensor on a gas range.…

Repair time and Difficulty

 15 minutes or less
How to replace a gas range oven control board

How to replace a gas range oven control board

These step-by-step instructions explain how to replace an oven control board on a gas range…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your central air conditioners

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Gas Snowblower
Microwave
Others
Parts
Range
Range Hood
Refrigerator
Riding Mowers & Tractors
Side-By-Side Refrigerator
Snowblower
Upright Vacuum
Vacuum Cleaner
Washer