Here are the diagrams and repair parts for ICP FSM2X3600A1 fan coil, as well as links to manuals and error code tables, if available.

ICP FSM2X3600A1 fan coil
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for FSM2X3600A1 Fan Coil

  • Capacitor for ICP FSM2X3600A1 - Part 1171730

    Blower assy diagram

    Capacitor

    Part #1171730

    The manufacturer no longer makes this part, and there's no substitute part

  • Bracket Coil for ICP FSM2X3600A1 - Part 1171574

    Coil assy diagram

    Bracket Coil

    Part #1171574

    The manufacturer no longer makes this part, and there's no substitute part

  • Coil & Hdr for ICP FSM2X3600A1 - Part 1172978

    Coil assy diagram

    Coil & Hdr

    Part #1172978

    The manufacturer no longer makes this part, and there's no substitute part

  • Wrapper for ICP FSM2X3600A1 - Part 1172048

    Cabinet assy diagram

    Wrapper

    Part #1172048

    The manufacturer no longer makes this part, and there's no substitute part

  • Angle Tie for ICP FSM2X3600A1 - Part 1173744

    Cabinet assy diagram

    Angle Tie

    Part #1173744

    The manufacturer no longer makes this part, and there's no substitute part

ICP Fan Coil FSM2X3600A1 FAQs

In an electric furnace or fan coil setup, the blower motor is typically turned on during the cooling cycle by the blower relay function on the control board (often called the fan control board). On the Icp FSM2X3600A1, that function is commonly handled by the air handler fan control board 1171734.

What the fan control board does in cooling

When your thermostat calls for cooling, the low-voltage signal is processed by the control board, which then energizes the indoor blower at the correct time and speed tap (or programmed speed) to move air across the evaporator coil.

Common control-board responsibilities include:

  • Turning the blower on after a cooling call starts
  • Keeping the blower running briefly after cooling stops (off-delay)
  • Managing blower speed selection (depending on system design)
  • Coordinating safety inputs (door switch, limits, condensate safety if equipped)

Quick checks before replacing parts

Shut off power at the breaker before opening any panels; fan coils contain high voltage.

  • Confirm the thermostat is set to Cool and the fan is Auto
  • Check for a clogged filter that can restrict airflow (use the correct size, such as central air conditioner air filter, 21-1/2 x 19-7/8 x 1-in 1171653 if it matches your setup)
  • Verify the indoor unit has power (no tripped breaker, service switch on)
  • Inspect for loose or burned wiring at the blower and control board
  • If the blower is completely dead, check the low-voltage supply (a failed transformer 1172028 can prevent the control circuit from operating)

Symptoms and likely causes

Symptom Most common cause What it points to
Outdoor unit runs, indoor blower never starts Control not energizing blower Fan control board/relay circuit
Blower runs only in “Fan On,” not in cooling Cooling call not being processed Thermostat signal or control board
Blower hums but will not spin Motor/capacitor/mechanical issue Blower motor system (not the relay)
No 24V control power Control power failure Transformer or wiring issue

Why it matters

If the blower does not run during cooling, the evaporator coil can freeze and airflow drops sharply; that can lead to poor comfort and additional strain on the system.

Last updated: February 2026

On a typical heat pump system, the blower motor is located in the indoor air handler or fan coil, not in the outdoor unit. For your Icp fan coil model FSM2X3600A1, that means the blower motor sits inside the cabinet where the return air filter and evaporator coil are.

What you will usually see when you open the indoor unit

In most fan coil and air handler designs, the blower assembly is positioned to pull air through the filter and coil, then push it into the ductwork.

  • Blower motor and blower wheel are in the lower or middle section of the cabinet
  • Evaporator coil is typically above the blower (upflow) or beside it (horizontal)
  • Filter slot is at the return-air side, upstream of the blower
  • Wiring harness and control board are mounted in a separate electrical compartment
  • Condensate drain pan is under the coil (near where moisture collects)

Quick location guide (indoor vs. outdoor)

Component Typical location What it does
Blower motor Indoor fan coil/air handler Moves air through ducts
Compressor Outdoor heat pump unit Pumps refrigerant
Condenser fan motor Outdoor heat pump unit Moves air across outdoor coil

Why it matters

If you are troubleshooting weak airflow, noisy operation, or no air movement, checking the indoor fan coil area first saves time. A clogged filter can also make the blower work harder and reduce heating and cooling performance.

Parts that commonly relate to blower and airflow issues

These are common service items we see tied to airflow complaints on fan coil systems:

Last updated: February 2026

Yes. An Icp fan coil like model FSM2X3600A1 can provide heat when it is paired with a heat source such as an electric heat kit or a hot-water coil, or when it is part of a heat pump system. The fan coil itself moves air across the indoor coil to deliver warm air.

How a fan coil provides heat

A fan coil is the indoor air-moving section; it does not “make” heat by itself in every setup. Heat output depends on what is installed with it.

Common heating configurations include:

  • Heat pump system: the indoor coil becomes the heating coil in heating mode
  • Electric heat strips (aux heat): electric elements add heat in the air handler
  • Hydronic (hot-water) coil: hot water from a boiler warms the coil
  • No heat installed: the unit can still circulate air and provide cooling, but not heat

Quick check: what you have at home

Use these clues to identify whether your FSM2X3600A1 setup is configured for heat:

  • Thermostat has HEAT mode and the system produces warm air
  • You see a separate electric heater compartment attached to the air handler
  • There is a hot-water line set going to a coil section (hydronic systems)
  • Outdoor unit is labeled as a heat pump (not cooling-only)

What to do if you get little or no heat

If the blower runs but the air is not warm, these are the most common causes:

Why it matters

Knowing whether your fan coil is configured for heat helps you troubleshoot correctly. A “no heat” complaint can be an airflow problem (filter or blower control) or a missing/failed heat source (electric heat kit, hydronic coil, or heat pump operation).

Symptom Most likely area to check first
Blower runs, air is cool in HEAT mode Heat source (heat pump, heat strips, hydronic coil)
Weak airflow, rooms never warm up Filter, blower speed, fan control board
Thermostat blank or clicking, no response Transformer, low-voltage circuit

Last updated: February 2026

If the fan on your Icp FSM2X3600A1 fan coil is not kicking on, the most common causes are a thermostat/call-for-fan issue, a power problem (breaker, fuse, door switch), a failed control board, or a low-voltage transformer problem. Start with power and thermostat checks before replacing parts.

Quick checks we recommend first

  • Set the thermostat to FAN = ON (not AUTO) and raise/lower temperature to force a call.
  • Check the air handler disconnect and your home breaker for the HVAC circuit.
  • Confirm the blower compartment door/panel is fully closed (many units have a safety switch).
  • Replace a dirty filter; restricted airflow can trigger safeties or overheating.
  • Look for burnt wiring, loose spade connectors, or corrosion on control terminals.

Parts that commonly cause “fan won’t run”

If power is present and the thermostat is calling for fan, these parts are common suspects for this model:

Symptom What it usually points to Part to check
No blower response in heat/cool or FAN ON Control not sending blower command Air handler fan control board 1171734
No 24 VAC control power (thermostat dead) Failed low-voltage supply Transformer 1172028
Fan runs weak, freezes up, or short-cycles Airflow restriction Central air conditioner air filter, 21-1/2 x 19-7/8 x 1-in 1171653

Safe troubleshooting steps (power off when opening panels)

  • Turn off power at the breaker/disconnect before removing access panels.
  • Inspect the filter and return air path; replace the filter if it is loaded with dust.
  • If you have a multimeter, verify 24 VAC at the control circuit and thermostat wiring.
  • Check for a blown low-voltage fuse on the control board (if equipped).
  • If the blower hums but will not spin, stop and have the motor/capacitor circuit checked by a technician.

For meter basics, we use the same approach shown in how to use a multimeter to test electrical parts video.

Why it matters

A fan that does not run can quickly lead to no heat/no cooling, coil freeze-up, or overheating shutdowns. Fixing airflow and control-power issues early helps prevent bigger repairs.

Last updated: February 2026

An HVAC heat pump system is made up of an outdoor unit (compressor and coil) and an indoor air handler or fan coil like the Icp FSM2X3600A1, plus controls, refrigerant lines, and air distribution. Inside the fan coil, the filter, blower, and electrical controls are key service parts.

Main parts you will typically find in a heat pump system

  • Outdoor unit: compressor, outdoor coil, condenser fan motor, defrost controls
  • Indoor unit (fan coil/air handler): evaporator coil, blower motor and wheel, drain pan and condensate drain
  • Refrigerant circuit: suction line, liquid line, metering device (TXV or piston), service valves
  • Electrical and controls: thermostat, low-voltage transformer, relays/boards, safety switches
  • Air distribution: return duct, supply duct, registers, return grille

Common service parts for Icp FSM2X3600A1

These are examples of parts we commonly see replaced on fan coils and air handlers:

Quick comparison: what each part does

Part Where it is What it affects when it fails
Air filter Return air path Low airflow, icing, poor heating/cooling, higher energy use
Fan control board Indoor unit control section Blower not running, wrong speed, intermittent operation
Transformer Indoor unit electrical section No 24V control power, thermostat appears dead

Why it matters

Knowing which section you are working on (outdoor unit vs. indoor fan coil vs. controls) helps you troubleshoot faster and order the right replacement part the first time. On the FSM2X3600A1, airflow and control-power issues often trace back to the filter, fan control board, or transformer.

Last updated: February 2026

Most common symptoms to help you fix your refrigerators

Choose a symptom to see related refrigerator repairs.

Main causes: leaky door gasket, defrost system failure, evaporator fan not running, dirty condenser coils, condenser fan…

Main causes: control board or cold control failure, broken compressor start relay, compressor motor failure, defrost tim…

Main causes: blocked vents, defrost system problems, evaporator fan failure, dirty condenser coils, bad sensors, condens…

Main causes: blocked air vents, compressor problems, condenser or evaporator fan not working, control system failure, se…

Main causes: water valve leaking, frozen or broken defrost drain tube, overflowing drain pan, cracked water system tubin…

Main causes: damaged door seal, faulty defrost sensor or bi-metal thermostat, broken defrost heater, bad defrost timer o…

Things to do: clean condenser coils, replace the water filter, clean the interior, adjust doors to prevent air leaks, cl…

Main causes: jammed ice cubes, broken ice maker assembly, dirty water filter, kinked water line, bad water valve, freeze…

Most common repair guides to help fix your refrigerators

These step-by-step repair guides will help you safely fix what’s broken on your refrigerator.

How to replace a refrigerator temperature control board

How to replace a refrigerator temperature control board

If the temperature in your refrigerator doesn't match the temperature you set, the problem could be the temperature cont…

Repair time and Difficulty

 30 minutes or less
How to replace a refrigerator water valve

How to replace a refrigerator water valve

Replace the water valve that feeds water to the ice maker and water dispenser if it no longer controls the flow of water…

Repair time and Difficulty

 15 minutes or less
How to clean refrigerator condenser coils

How to clean refrigerator condenser coils

Help your refrigerator run more efficiently by cleaning the condenser coils. It's easy and takes just a few minutes.…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your refrigerators

Use the advice and tips in these articles and videos to get the most out of your refrigerator.

How to Replace the Water Filter in a Universal/Multiflex Refrigerator

How to Replace the Water Filter in a Universal/Multiflex Refrigerator

Learn how easy replacing the water filter in a Universal/Multiflex refrigerator is.…

How to Replace the Water Filter in a KitchenAid Refrigerator

How to Replace the Water Filter in a KitchenAid Refrigerator

Discover how easy it is to replace the water filter in your KitchenAid refrigerator.…

Troubleshooting a refrigerator not cooling video

Troubleshooting a refrigerator not cooling video