Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Coleman PM0545008 generator

Coleman PM0545008 generator Parts

Here are the diagrams and repair parts for Coleman PM0545008 generator, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for PM0545008 Generator

  • Adapter, Engine, Nsp for Coleman PM0545008 - Part N/P

    Adapter, Engine, Nsp

    Part #N/P

    The manufacturer no longer makes this part, and there's no substitute part

  • Lug,ground for Coleman PM0545008 - Part 0008854

    Electric generator diagram

    Lug,ground

    Part #0008854

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt for Coleman PM0545008 - Part 0040816.01

    Electric generator diagram

    Bolt

    Part #0040816.01

    The manufacturer no longer makes this part, and there's no substitute part

  • Nut,nyloc for Coleman PM0545008 - Part 0048736

    Electric generator diagram

    Nut,nyloc

    Part #0048736

    The manufacturer no longer makes this part, and there's no substitute part

  • Flat Washer for Coleman PM0545008 - Part 0049352

    Electric generator diagram

    Flat Washer

    Part #0049352

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw for Coleman PM0545008 - Part 0058618

    Electric generator diagram

    Screw

    Part #0058618

    The manufacturer no longer makes this part, and there's no substitute part

  • Stator 5 Kw 60 Hz for Coleman PM0545008 - Part 0062471

    Electric generator diagram

    Stator 5 Kw 60 Hz

    Part #0062471

    The manufacturer no longer makes this part, and there's no substitute part

  • Rectify Brd for Coleman PM0545008 - Part 0062455

    Electric generator diagram

    Rectify Brd

    Part #0062455

    The manufacturer no longer makes this part, and there's no substitute part

Coleman Generator PM0545008 FAQs

Runtime on the Coleman PM0545008 depends mainly on fuel tank level and how many watts you draw; heavier loads burn fuel faster. For the most accurate run-time guidance for your setup, use the operating and fueling instructions in the PM0545008 owner's manual.

What determines runtime on this model

  • Electrical load (watts/amps): more load equals shorter runtime
  • Motor starting surges: pumps and compressors can spike demand
  • Fuel quality and carburetion: stale fuel can cause inefficient running
  • Altitude and temperature: higher altitude and heat reduce available power
  • How loads are distributed: uneven loading can cause nuisance breaker trips

Simple way to estimate your runtime

  1. Add up the running watts of everything you plan to power.
  2. Keep total demand within the generator’s rated output (check the nameplate ratings).
  3. Test your real-world load for 15 to 30 minutes and monitor fuel use; then scale that rate to your tank level.

Planning table

Load level Example use What to expect
Light (about 25%) lights, chargers, small tools Longest runtime per tank
Medium (about 50%) mixed essentials Moderate runtime per tank
Heavy (75% to 100%) many loads, frequent motor starts Shortest runtime; refuel more often

How to maximize runtime safely

  • Run only the loads you need; turn off high-draw items when not in use.
  • Balance loads across available receptacles to reduce overheating and trips.
  • Let the generator cool before refueling; shut it off and keep fuel away from ignition sources.
  • Use a watt meter or clamp meter to confirm actual draw if you are near the limit.

Why it matters

Accurate runtime planning prevents overloads, breaker trips, and voltage drop, especially when powering multiple circuits through the generator’s receptacles and cord set.

Last updated: February 2026

The most common issues we see with the Coleman PM0545008 generator are no-start conditions, rough running or surging, and no AC power output. These problems usually trace to fuel quality, ignition and spark, airflow, or basic electrical protection devices like breakers and fuses; use the PM0545008 owner's manual for model-specific checks and specs.

Common symptoms and what they usually mean

  • Won’t start: stale fuel, clogged carburetor jets, dirty air filter, fouled spark plug, low oil shutdown
  • Starts then dies: restricted fuel flow, stuck choke, dirty carburetor, tank vent issue
  • Surging (hunting): partially clogged carburetor, air leak, governor linkage sticking
  • No AC power: tripped breaker, blown fuse (if equipped), bad receptacle, wiring issue, failed capacitor/AVR (if equipped)
  • Low power or bogging under load: overloaded circuits, dirty air filter, fuel restriction, engine speed out of spec
  • Excess vibration/noise: loose fasteners, damaged mounts, unbalanced load, engine misfire

Quick checks we recommend first (safe, high-impact)

  1. Disconnect all loads and try starting again.
  2. Verify fresh gasoline and the fuel valve is ON.
  3. Set choke correctly (more choke cold, less as it warms).
  4. Check oil level; many generators will not run if oil is low.
  5. Inspect the air filter and spark plug condition.
  6. Reset any circuit breakers on the control panel.

Troubleshooting map (symptom to next step)

Symptom Most likely area Best next step
Cranks but won’t fire Fuel or spark Check spark plug, then fuel flow/carburetor
Runs rough/surges Fuel/air/governor Clean carburetor, check air filter, inspect linkages
Runs fine but no outlets work Breaker/wiring/regulation Reset breaker, test receptacle voltage with a meter
Dies when load is applied Overload or engine output Reduce load, verify engine speed, check air/fuel

Why it matters

Generator problems often look “electrical,” but many PM0545008 complaints start with fuel varnish or restricted airflow. Fixing the root cause prevents repeated no-starts, protects connected equipment, and helps the engine hold steady RPM for stable voltage.

Helpful DIY reference

If you need to test output safely, a meter is the right tool; follow how to use a multimeter to test electrical parts video for the basics before checking receptacles or continuity.

Last updated: March 2026

The Coleman generator model PM0545008 uses a 10 HP Briggs & Stratton (B&S) OHV engine. We list it in the parts breakdown as “Engine 10 hp B&S OHV,” which matches the factory configuration for this generator.

Where we confirm the engine

You can verify the engine callout in the parts list/drawing in the owner's manual. Look for the engine line item in the reference table.

What “10 HP B&S OHV” means

  • 10 HP: the engine horsepower rating used for this generator configuration.
  • Briggs & Stratton (B&S): the engine manufacturer.
  • OHV: overhead valve design, commonly used for better efficiency and durability.

Quick ID checklist (on the generator)

Use these checks to confirm you are matching the correct engine to your exact unit:

  • Check the engine label on the recoil starter housing or valve cover area.
  • Match the generator model number PM0545008 on the generator data tag.
  • Compare the parts drawing in the manual to what you see on the frame and engine mounts.
  • Confirm whether your unit is original or has had an engine swap in the past.

Replacement and service notes

The manual notes that engines are typically handled through the engine manufacturer’s warranty coverage rather than being supplied as a standard generator replacement part.

Task Best reference Why it matters
Identify exact engine model/type code Engine label + owner's manual Ensures correct tune-up and repair parts
Find generator-side parts (mounts, adapters, isolators) Owner's manual parts list Prevents fit and alignment issues
Electrical troubleshooting (output issues) Wiring/parts diagram Avoids misdiagnosing engine vs alternator problems

Why it matters

Using the correct engine identification helps you buy the right maintenance items (spark plug, air filter, carburetor parts) and prevents mismatches when diagnosing “won’t start” versus “no power output” problems.

Last updated: February 2026

Repair guides for side-by-side refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a press-in door gasket in a side-by-side refrigerator

How to replace a press-in door gasket in a side-by-side refrigerator

The door gasket seals the gap around the door to keep the cold air in and the warm air out. Replace a worn or damaged do…

Repair time and Difficulty

 15 minutes or less
How to replace an ice maker in a side-by-side refrigerator

How to replace an ice maker in a side-by-side refrigerator

Learn how to replace the ice maker in a side-by-side refrigerator with these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Articles and videos for side-by-side refrigerators

How to reset the door alarm on a GE refrigerator

How to reset the door alarm on a GE refrigerator

Your fridge is tattling again. Here’s how to reset the door alarm on your GE refrigerator—and how to tell if the beeping…

How to Replace the Water Filter in a Kenmore Pro Refrigerator

How to Replace the Water Filter in a Kenmore Pro Refrigerator

Discover how easy it is to replace the water filter in a Kenmore Pro refrigerator.…

Common Refrigerator Ice Maker Problems and Solutions

Common Refrigerator Ice Maker Problems and Solutions

Find tips on how to fix the ice maker in your fridge when it isn't working or when it isn't working right.…

Parts & More

Parts