Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Carrier 38EZG048 SERIES300 condensing unit

Carrier 38EZG048 SERIES300 condensing unit Parts

Here are the diagrams and repair parts for Carrier 38EZG048 SERIES300 condensing unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 38EZG048 SERIES300 Condensing Unit

  • Label Id for Carrier 38EZG048 SERIES300 - Part 325658-101

    #9

    All parts diagram

    Label Id

    Part #325658-101

    The manufacturer no longer makes this part, and there's no substitute part

  • Delay Kit for Carrier 38EZG048 SERIES300 - Part KAATD0101TDR

    #66

    All parts diagram

    Delay Kit

    Part #KAATD0101TDR

    The manufacturer no longer makes this part, and there's no substitute part

  • Valve for Carrier 38EZG048 SERIES300 - Part EC39DM061

    #62C

    All parts diagram

    Valve

    Part #EC39DM061

    The manufacturer no longer makes this part, and there's no substitute part

  • Switch for Carrier 38EZG048 SERIES300 - Part 312926-237

    #39

    All parts diagram

    Switch

    Part #312926-237

    The manufacturer no longer makes this part, and there's no substitute part

  • Ring Pistn for Carrier 38EZG048 SERIES300 - Part 323455-401

    #57

    All parts diagram

    Ring Pistn

    Part #323455-401

    The manufacturer no longer makes this part, and there's no substitute part

  • Raceway for Carrier 38EZG048 SERIES300 - Part 319421-302

    #45

    All parts diagram

    Raceway

    Part #319421-302

    The manufacturer no longer makes this part, and there's no substitute part

  • 045,kit,frz Therm(46) for Carrier 38EZG048 SERIES300 - Part KAAFT0101AAA

    #79

    All parts diagram

    045,kit,frz Therm(46)

    Part #KAAFT0101AAA

    The manufacturer no longer makes this part, and there's no substitute part

  • Piston Body Kit for Carrier 38EZG048 SERIES300 - Part KSAPX0101PIS

    #91

    All parts diagram

    Piston Body Kit

    Part #KSAPX0101PIS

    The manufacturer no longer makes this part, and there's no substitute part

  • Top Cap for Carrier 38EZG048 SERIES300 - Part 312249-402

    #7

    All parts diagram

    Top Cap

    Part #312249-402

    The manufacturer no longer makes this part, and there's no substitute part

  • Cap for Carrier 38EZG048 SERIES300 - Part 99CC501202

    #58

    All parts diagram

    Cap

    Part #99CC501202

    The manufacturer no longer makes this part, and there's no substitute part

Carrier Condensing Unit 38EZG048 SERIES300 FAQs

The Carrier 38EZG048 condensing unit is a 4-ton central air conditioner (about 48,000 BTU/hr of cooling). For the exact capacity and approved indoor coil matches for your specific system, confirm the rating plate data and the combinations listed in the installation guide.

How we determine tonnage from the model number

Most central AC model numbers use the last three digits to indicate nominal capacity in thousands of BTU per hour.

  • 048 typically means 48,000 BTU/hr
  • 1 ton = 12,000 BTU/hr
  • 48,000 ÷ 12,000 = 4 tons
  • This is a nominal rating; actual delivered capacity varies with indoor coil, airflow, and outdoor conditions
Model capacity code Nominal BTU/hr Nominal tons
024 24,000 2.0
030 30,000 2.5
036 36,000 3.0
048 48,000 4.0
060 60,000 5.0
Why the exact match matters (coil, metering device, and refrigerant)

Getting the tonnage right is only part of sizing a system. The installation instructions for the 38EZG series call out that the indoor coil metering device must match the outdoor unit requirements (piston or TXV), and Puron systems operate at higher pressures than R-22 systems.

  • A mismatched indoor coil or metering device can cause poor cooling and compressor stress
  • The guide notes checking the indoor coil piston against the outdoor unit rating plate
  • If a TXV is used, the piston must be removed for proper TXV operation
  • Outdoor operating ambient range in cooling mode is 55°F to 125°F
Quick checks before you order parts

If you are troubleshooting a 38EZG048 that is not cooling, confirm the basics first.

  • Verify thermostat is calling for cooling and indoor blower is running
  • Check for a pulled-in contactor and correct line voltage at the disconnect
  • Confirm condenser fan runs; a failed motor can cause high head pressure
  • Inspect wiring for loose or burned connections
  • If the compressor struggles to start, a hard start kit may be part of the fix

If you need common electrical or fan-drive parts for this model, we list options such as the central air conditioner condenser fan motor HC39GE237 and the central air conditioner compressor hard start kit KSAHS1501AAA.

Why it matters

A 4-ton condenser paired with the wrong indoor coil, piston/TXV setup, or airflow can short-cycle, ice the coil, or run inefficiently. Confirming the nominal tonnage and then verifying the approved system match helps protect the compressor and improves comfort.

Last updated: February 2026

On a Carrier 38EZG048 condensing unit, the model number is printed on the outdoor unit’s rating plate (data tag). We use that exact model number to match the correct diagrams and replacement parts for your central air conditioner.

Where to look on the outdoor unit

Check these common rating-plate locations:

  • On the outside cabinet near the refrigerant service valves
  • Inside the electrical/control panel access door
  • On a side panel near where the power conduit enters
  • Near the compressor compartment opening (visible after removing the service panel)
What the label looks like

The data tag usually includes several fields. Use the model field, not the serial.

Label field What it’s for
Model Identifies the exact unit configuration for parts
Serial Manufacturing identifier, not used for most parts lookups
Electrical (V/PH/Hz, MCA, MOCP) Helps confirm correct power and breaker sizing
Tips to avoid mix-ups
  • Write the model number exactly as shown (letters, numbers, dashes)
  • If the tag is faded, take a clear photo in good light
  • Confirm you are reading the outdoor unit tag (not the indoor furnace/air handler)
Why it matters

Carrier condensing units can look similar across series; the correct model number ensures you get the right contactor, condenser fan motor, or compressor match.

For a diagram showing typical label locations and service access panels, use the 38EZG048 installation guide. If you need help identifying the right tag, the article how to find your appliance model number (and what it means for parts) walks through what to look for.

Last updated: March 2026

For the Carrier 38EZG048 condensing unit, start troubleshooting by confirming thermostat settings and power to the outdoor unit, then check for airflow and obvious electrical issues. Many “no cool” problems trace to a tripped disconnect/breaker, a failed contactor, or a condenser fan problem.

Quick safety and setup

Central air conditioners use high voltage and stored electrical energy; shut off power at the disconnect and breaker before opening panels.

  • Set thermostat to Cool and lower the setpoint 3 to 5 degrees
  • Wait 5 minutes (many systems have a built-in delay)
  • Turn off power at the outdoor disconnect and main breaker before inspecting
  • Keep the condenser coil area clear (leaves, grass, lint)
  • Replace/clean the indoor air filter to prevent icing and low airflow
What to check first (most common)
  • Outdoor unit silent: verify breaker/disconnect, then inspect the contactor for pitting/burn marks
  • Outdoor unit hums but fan not spinning: suspect the fan motor or a failed capacitor (common on condensing units)
  • Fan runs but no cooling: check for a dirty coil, indoor airflow restrictions, or compressor not starting
  • Short cycling: look for overheating from a dirty coil, loose wiring, or a weak start component
Symptom-to-likely-cause guide
Symptom Likely area What we do next
No outdoor operation Power, contactor Confirm line voltage, inspect contacts and wiring
Fan not running Fan motor, capacitor Spin test (power off), check motor amps/voltage
Compressor won’t start Start components Consider a hard start kit if appropriate
Icing on lines/coil Airflow, refrigerant Fix airflow first; refrigerant issues need a technician
Parts that commonly fail on this model

If your diagnosis points to a specific component, these are common service parts for the 38EZG048:

Why it matters

Accurate troubleshooting prevents repeat failures. For example, replacing a fan motor without correcting a dirty condenser coil can overheat the new motor and shorten its life.

For wiring diagrams, component locations, and model-specific checks, use the 38EZG048 owner's manual and follow the electrical test procedures.

Last updated: March 2026

Repair guides for bottom-mount refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a door gasket in a French-door refrigerator

How to replace a door gasket in a French-door refrigerator

The door gasket, often called a door seal, seals the gap around the door to keep the cold air in and the warm air out. R…

Repair time and Difficulty

 15 minutes or less
How to replace an in-door ice maker on a French door refrigerator

How to replace an in-door ice maker on a French door refrigerator

Follow these step-by-step instructions how to replace the in-door ice maker in Kenmore TRIO and LG French door refrigera…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your central air conditioners

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Bottom-Mount Refrigerator
Dehumidifier
Electric Range
Exercise Cycle
Front-Engine Lawn Tractor
Gas Line Trimmer
Gas Pressure Washer
Gas Range
Gas Snowblower
Ice Cream Maker
Parts
Refrigerator
Room Air Conditioner
Side-By-Side Refrigerator
Top-Mount Refrigerator
Treadmill
Washer