Here are the diagrams and repair parts for Goodman GMT070-3B gas furnace, as well as links to manuals and error code tables, if available.

Goodman GMT070-3B gas furnace
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for GMT070-3B Gas Furnace

  • Furnace Burner for Goodman GMT070-3B - Part B4022700

    Burner box assembly diagram

    Furnace Burner

    In Stock
    $34.62
    15% OFF Phone Price : $40.62Info Icon
    Minus Item
    Qty
    Plus Item
  • Door-accs for Goodman GMT070-3B - Part 4012000P

    Wrapper assembly diagram

    Door-accs

    In Stock
    $42.42
    Minus Item
    Qty
    Plus Item
  • Burner Rack for Goodman GMT070-3B - Part 0121F00157

    Burner box assembly diagram

    Rack

    Part #2513501

    Replaced by #0121F00157

    Info Icon
    Manufacturer substitution
    This part replaces 2513501. Substitute parts can look different from the original.
    In Stock
    $34.90
    Minus Item
    Qty
    Plus Item
  • Burner for Goodman GMT070-3B - Part 0121F00146

    Burner box assembly diagram

    Side

    Part #2514000

    Replaced by #0121F00146

    Info Icon
    Manufacturer substitution
    This part replaces 2514000. Substitute parts can look different from the original.
    In Stock
    $24.40
    Minus Item
    Qty
    Plus Item
  • Furnace Blower Fan Motor Housing for Goodman GMT070-3B - Part 2539305S

    Blower assembly diagram

    Shell

    Part #2539305

    Replaced by #2539305S

    Info Icon
    Manufacturer substitution
    This part replaces 2539305. Substitute parts can look different from the original.
    In Stock
    $118.16
    9% OFF Phone Price : $130.16Info Icon
    Minus Item
    Qty
    Plus Item
  • Goodman Blw Mtr Psc 1/2hp 1130rpm 115v for Goodman GMT070-3B - Part 0131F00042SP

    Blower assembly diagram

    Furnace Blower Fan Motor

    Part #0131F00022

    Replaced by #0131F00042SP

    Info Icon
    Manufacturer substitution
    This part replaces 0131F00022. Substitute parts can look different from the original.
    In Stock
    $422.68
    Minus Item
    Qty
    Plus Item
  • Burner Rck for Goodman GMT070-3B - Part 0121F00159

    Burner box assembly diagram

    Rack

    Part #2513503

    Replaced by #0121F00159

    Info Icon
    Manufacturer substitution
    This part replaces 2513503. Substitute parts can look different from the original.
    In Stock
    $116.86
    Minus Item
    Qty
    Plus Item
  • Top, Painted, 24.5" (gmt140-5b) for Goodman GMT070-3B - Part 4008011P

    Wrapper assembly diagram

    Top, Painted, 24.5" (gmt140-5b)

    Part #4008011P

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel for Goodman GMT070-3B - Part 4815801

    Wrapper assembly diagram

    Panel

    Part #4815801

    The manufacturer no longer makes this part, and there's no substitute part

  • Primary Limit Switch, 190f (gmth045-3b) for Goodman GMT070-3B - Part B1370199

    Heat exchanger assembly diagram

    Primary Limit Switch, 190f (gmth045-3b)

    Part #B1370199

    The manufacturer no longer makes this part, and there's no substitute part

Goodman Gas Furnace GMT070-3B FAQs

To reset an E3 error on your Goodman GMT070-3B gas furnace, turn off power to the furnace at the switch or breaker for a few minutes, then restore power. This power-cycle resets the control board and often clears a stored fault after the underlying issue is corrected.

Safe reset steps (power-cycle)

  • Set the thermostat to OFF.
  • Turn OFF power to the furnace at the service switch or circuit breaker.
  • Wait 3 to 5 minutes.
  • Turn power ON.
  • Set the thermostat back to HEAT and call for heat.

If the E3 code comes back

An E3 code usually returns because the furnace is still detecting a problem. These checks are the most common next steps:

  • Replace a dirty air filter and make sure supply registers are open.
  • Confirm the blower door is fully closed (door switch engaged).
  • Check the venting and intake for blockage (snow, nests, debris).
  • Listen for the inducer motor starting; if it does not, the pressure switch may not close.
  • Watch the ignition sequence; if it fails to light reliably, the igniter or ignition control may be involved.

Parts that commonly relate to “won’t start” or repeated fault codes

If troubleshooting points to a failed component, these model-matched parts are commonly involved:

Symptom you notice Common part to inspect/replace Example part for GMT070-3B
Inducer does not run, pressure switch never proves Pressure switch or inducer assembly Furnace air pressure switch B1370176 or vent motor B4833000S
Ignition sequence fails or is erratic Igniter or ignition control Igniter B1401018S or furnace hot-surface ignition control board B1809913S
Furnace starts then shuts down quickly Limit or rollout switch opening Furnace temperature limit switch B1370198 or furnace burner roll-out limit switch B1370145

Why it matters

Resetting clears the control’s stored fault, but it does not fix the condition that triggered E3. If E3 repeats, addressing airflow, venting, ignition, or safety-switch issues prevents nuisance shutdowns and protects key components like the heat exchanger.

For model-specific access panels, wiring routing, and the exact ignition sequence for the GMT070-3B, use the installation guide.

Last updated: February 2026

On a Goodman GMT070-3B gas furnace, a “pressure switch stuck open” condition usually means the inducer is not creating enough draft or the switch is not sensing it through the tubing. We fix it by restoring proper airflow (venting, condensate, hoses) and then testing the pressure switch circuit per the installation guide.

Safety first (do this before troubleshooting)

  • Turn off electrical power at the furnace switch or breaker.
  • Shut off the gas supply valve if you will open the burner compartment.
  • Let the furnace cool; limit switches and burners can be hot.
  • If you smell gas, stop and have a qualified technician handle the repair.

Step-by-step checks that solve most “stuck open” calls

  • Check the inducer starts and runs: If the inducer does not run, the pressure switch will stay open.
  • Inspect the pressure switch hose: Remove the hose and look for water, cracks, soft spots, or blockage; clear it and reinstall firmly.
  • Clear the inducer port: The small port on the inducer housing that the hose connects to can plug with debris; clean it carefully.
  • Verify venting and intake are open: Look for snow, nests, leaves, or sagging pipe that traps water.
  • Check condensate drainage (high-efficiency setups): A backed-up drain can flood the pressure tubing and prevent the switch from closing.
  • Confirm wiring connections: Loose spade terminals at the pressure switch or control board can mimic an “open” switch.

Quick diagnostic: what the symptom usually points to

What you observe Most likely cause What to do next
Inducer never starts Control issue, motor issue, or no power Check power, door switch, wiring; test inducer circuit
Inducer runs but no “click” from switch Blocked hose/port, vent restriction, weak inducer Clear restrictions; inspect venting; verify inducer performance
Switch clicks but furnace still faults Wiring, control board input, intermittent draft Inspect connectors; check for water in tubing; test continuity

When a part replacement is the right fix

Replace the pressure switch when the hose/port/venting are clear, the inducer runs properly, and the switch will not close reliably under normal draft.

Why it matters

The pressure switch is a safety device; it proves the inducer is venting combustion gases before ignition. Bypassing it or forcing it closed can create unsafe operation and repeated lockouts.

Last updated: February 2026

On a Goodman GMT070-3B gas furnace, “code 7” is commonly used to indicate a gas valve fault or a problem in the gas valve control circuit. We use the furnace’s diagnostic chart and wiring diagram in the installation guide to confirm the exact meaning for your setup before replacing parts.

What to check first (safe, high-value checks)

  • Set the thermostat to OFF, then restore a call for heat and watch the LED sequence again.
  • Confirm the gas shutoff valve is fully open and other gas appliances are working.
  • Replace the air filter and make sure supply and return vents are open (overheating can create confusing symptoms).
  • Inspect the low-voltage wiring at the control board and gas valve for loose spade terminals or rubbed insulation.
  • Verify the furnace has a solid ground and correct polarity (hot and neutral not reversed).

Likely causes and what they look like

Likely cause What you may notice What we typically do next
Gas valve not opening or valve circuit issue No burner flame, repeated ignition attempts Check wiring, then test voltage to valve during ignition
Ignition control problem Igniter glows but burners do not light, or no ignition sequence Inspect/diagnose the control board and safety circuit
Draft/pressure proving issue (can stop gas valve command) Inducer runs, then shutdown before flame Check venting, hoses, and pressure switch operation

Parts that often relate to a “gas valve fault” style code

If your troubleshooting confirms the furnace is not properly commanding or proving ignition, these model-matched parts are common suspects:

Why it matters

A code tied to the gas valve or its control circuit is a safety-related shutdown. Correct diagnosis prevents unnecessary part replacement and helps ensure the ignition sequence, draft proving, and flame lighting all happen in the right order.

Last updated: February 2026

A Goodman gas furnace like model GMT070-3B typically lasts 15 to 20 years. With correct setup, clean airflow, and annual service, it reaches the high end of that range; chronic overheating, short-cycling, or poor venting shortens lifespan.

Typical lifespan ranges (what we see most often)

  • 15 to 20 years: normal life expectancy for a residential gas furnace
  • 10 to 12 years: common when maintenance is skipped or the furnace frequently overheats
  • 20+ years: achievable with consistent upkeep and stable operating conditions
Condition What it usually looks like Expected outcome
Well maintained Clean filter, steady airflow, annual tune-up Longer service life
High stress use Long run times, frequent cycling, dusty returns Shorter service life
Airflow restricted Dirty filter, blocked vents, weak blower performance Overheating and early wear

What most affects furnace life

  • Airflow and filtration: A clogged filter or closed registers can trip the limit switch and overheat the heat exchanger.
  • Ignition reliability: Repeated ignition failures add wear to controls and igniters.
  • Venting and draft: Poor draft can cause nuisance shutdowns and stress the inducer system.
  • Heat exchanger condition: Cracks, corrosion, or repeated overheating are end-of-life indicators.
  • Electrical health: Loose or damaged wiring can cause intermittent failures.

Practical maintenance that extends life

  • Replace the air filter on schedule (many homes need every 1 to 3 months).
  • Keep supply registers open and return grilles unobstructed.
  • Follow venting, clearances, and setup guidance in the installation guide.
  • Have a technician perform annual combustion and safety checks.
  • If you are troubleshooting electrical issues, use safe test practices from our how to use a multimeter to test electrical parts video.

Why it matters

A furnace near the end of its expected life is more likely to have intermittent no-heat calls, higher operating noise, and repeated safety shutdowns. Catching airflow, ignition, or venting problems early helps protect major components like the heat exchanger and inducer.

Last updated: February 2026

Symptoms for electric ranges

Main causes: faulty surface element, burner control switch failure, temperature limiter not working properly, loose wiri…

Main causes: impact from dropping an item on the glass surface, ceramic glass surface flaw, surface element temperature …

Repair guides for electric ranges

How to replace an oven temperature sensor on an electric range

How to replace an oven temperature sensor on an electric range

These step-by-step instructions guide you through replacing an oven temperature sensing probe.…

Repair time and Difficulty

 15 minutes or less
How to replace an electric range oven control board

How to replace an electric range oven control board

If the electronic oven control board isn't powering the bake and broil functions, you can replace it in less than half a…

Repair time and Difficulty

 15 minutes or less
How to replace a range surface element control switch

How to replace a range surface element control switch

The surface element control switch lets you turn the stovetop elements on and off, and to set the heat level. These step…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Automotive
Bottom-Mount Refrigerator
Dishwasher
Electronic Sewing Machine
Gas Range
Gas Walk-Behind Mower
Iron Filter
Parts
Side-By-Side Refrigerator
Weight System