What are the most common issues with 79551833416?
The most common issues we see on the Kenmore 79551833416 side-by-side refrigerator involve ice and water dispensing problems, warm temperatures from airflow or fan issues, water leaks from drain or tubing, and door sealing or alignment problems. Many of these symptoms trace back to a few serviceable parts and basic maintenance.
Common symptoms and what usually causes them
- No ice or slow ice production: clogged filter, low water pressure, or a failing ice maker
- Water dispenser slow or not dispensing: restricted filter, frozen reservoir line, or a weak inlet valve
- Refrigerator warm but freezer cold (or vice versa): airflow restriction, damper problem, or fan issue
- Puddles or water under the refrigerator: clogged/iced drain tube, loose water line fitting
- Frost buildup or moisture around doors: worn or warped door gasket, door not closing fully
- Clicking, buzzing, or unusual fan noise: condenser fan blade damage or motor wear
Parts that commonly solve these problems (when symptoms match)
| Symptom | Part to check | Example from this model’s parts |
|---|---|---|
| Bad taste/odor, slow water | Water filter | Kenmore refrigerator water filter 9490 ADQ73613402 |
| No water to dispenser/ice maker | Water inlet valve | Refrigerator water inlet valve AJU34125566 |
| Warm temps, poor cooling | Condenser fan motor/blade | Refrigerator condenser fan motor EAU65058326, refrigerator condenser fan blade ADP73273401 |
| Leaking inside or under unit | Drain tube assembly | Refrigerator drain tube assembly 5251JA3004E |
| Air leaks, sweating, frost | Door gasket | Refrigerator door gasket 4987JJ1010Z |
Quick checks we recommend before replacing parts
- Confirm controls are set correctly; allow 24 hours after changes for temperatures to stabilize.
- Make sure vents inside both compartments are not blocked by food packages.
- Clean condenser coils and verify the condenser fan runs when the compressor is running.
- Inspect the door seal for gaps; close a dollar bill in the door and check for easy pull-out.
- If you have a water dispenser, replace the filter on schedule and flush several gallons after installing.
Why it matters
Ice, water, and cooling complaints often share the same root causes: restricted airflow, restricted water flow, or a door that is not sealing. Fixing the underlying cause protects food temperatures, reduces frost, and helps the compressor run less.
For model-specific operating details and maintenance intervals, use the owner's manual.
Last updated: March 2026
What does er if mean on a Kenmore refrigerator?
On Kenmore refrigerator model 79551833416, the ER IF code points to a problem with the ice fan (ice room fan) airflow or operation, which can stop or slow ice production and sometimes affect freezer temperatures. We use the troubleshooting steps in the 79551833416 owner's manual to confirm the fan is running and the air path is clear.
What to check first (fast, no parts)
- Make sure the ice bin is seated correctly and not overfilled.
- Break up ice clumps that can block airflow near the ice room.
- Check for frost or ice buildup around the ice fan cover or vents.
- Confirm the freezer door closes fully and the gasket seals.
- Power reset: unplug the refrigerator (or switch breaker off) for 5 minutes, then restore power.
Common causes and what they look like
| Likely cause | What you may notice | Typical fix |
|---|---|---|
| Ice fan blocked by frost/ice | ER IF comes back after reset; fan area looks frosty | Defrost blockage; improve door sealing |
| Ice fan not running | No airflow sound near ice room; warm ice room | Diagnose fan motor and wiring |
| Dispenser/ice door not sealing | Frost near chute; ice clumping | Inspect chute door and mechanism |
| Control or sensor issue | Code appears intermittently | Follow diagnostic steps in manual |
When a part is commonly involved
If the fan itself is not operating after clearing ice and resetting power, the ice chute area and fan-related components are common suspects. For this model, a dispenser-related part that can contribute to icing and airflow issues is the refrigerator dispenser ice chute door motor EAU59551204.
Why it matters
The ice fan moves cold air to the ice room; when airflow is blocked or the fan fails, the ice maker can slow down, ice can clump, and frost can spread into the dispenser area.
Last updated: January 2026
What size is Kenmore refrigerator model 79551833416?
Kenmore refrigerator model 79551833416 is a Kenmore 795.5183* side-by-side refrigerator. For the exact exterior dimensions (width, height, depth) and required installation clearances for your specific unit, use the measurements and clearance diagrams in the 79551833416 owner's manual.
What “size” usually means for a side-by-side refrigerator
When customers ask for size, we recommend confirming these four measurements on the appliance and in the installation section of the manual:
- Overall width (widest point, often the hinge side)
- Overall height (floor to top, including hinge cover if used)
- Overall depth (cabinet only and with handles)
- Required clearances (space behind, above, and at the sides for airflow and door swing)
Quick measuring checklist (at home)
Use a tape measure and record both “cabinet only” and “as installed” dimensions.
- Measure width at the front across the widest point
- Measure height from floor to the highest point
- Measure depth from the back to the front edge (then add handle projection)
- Measure the opening (cabinet cutout) and compare to the refrigerator
- Measure the narrowest doorway on the path into the kitchen
Planning table (what to write down)
| Measurement | Measure from | Include |
|---|---|---|
| Width | leftmost to rightmost point | hinges/trim if they stick out |
| Height | floor to top | hinge cover/top cap |
| Depth (cabinet) | back to front of cabinet | no handles |
| Depth (installed) | back to front of handles | handles and door curvature |
Why it matters
Correct dimensions and clearances prevent installation problems, protect airflow for proper cooling, and help avoid door swing and leveling issues.
Last updated: January 2026