Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Goodman GMP100-3 gas furnace

Goodman GMP100-3 gas furnace Parts

Here are the diagrams and repair parts for Goodman GMP100-3 gas furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for GMP100-3 Gas Furnace

  • Restrictor for Goodman GMP100-3 - Part 2528002S

    #11

    All parts diagram

    Flue Rstrctr

    Part #25280-02S

    Replaced by #2528002S

    Info Icon
    Manufacturer substitution
    This part replaces 25280-02S. Substitute parts can look different from the original.
    In Stock
    $58.28
    Minus Item
    Qty
    Plus Item
  • Central Air Conditioner Air Handler Blower Wheel for Goodman GMP100-3 - Part B1368016S

    #36

    All parts diagram

    Blower Wheel

    Part #B13680-16

    Replaced by #B1368016S

    Info Icon
    Manufacturer substitution
    This part replaces B13680-16. Substitute parts can look different from the original.
    In Stock
    $235.99
    Minus Item
    Qty
    Plus Item
  • Access Door for Goodman GMP100-3 - Part 0221F00028PDG

    #2

    All parts diagram

    Door-accs

    Part #25125-09

    Replaced by #0221F00028PDG

    Info Icon
    Manufacturer substitution
    This part replaces 25125-09. Substitute parts can look different from the original.
    In Stock
    $65.80
    Minus Item
    Qty
    Plus Item
  • Burner for Goodman GMP100-3 - Part 0121F00146

    #26

    All parts diagram

    Burner Side

    Part #25140-00

    Replaced by #0121F00146

    Info Icon
    Manufacturer substitution
    This part replaces 25140-00. Substitute parts can look different from the original.
    In Stock
    $24.40
    Minus Item
    Qty
    Plus Item
  • 17" Duct Ang for Goodman GMP100-3 - Part 25240-01

    #5

    All parts diagram

    17" Duct Ang

    Part #25240-01

    The manufacturer no longer makes this part, and there's no substitute part

  • 4 Cl, Burner for Goodman GMP100-3 - Part 25135-02

    #28

    All parts diagram

    4 Cl, Burner

    Part #25135-02

    The manufacturer no longer makes this part, and there's no substitute part

  • 4 Cl, Burner for Goodman GMP100-3 - Part 25130-02

    #27

    All parts diagram

    4 Cl, Burner

    Part #25130-02

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Flue Collector Box for Goodman GMP100-3 - Part 25100-01S

    #10

    All parts diagram

    Furnace Flue Collector Box

    Part #25100-01S

    The manufacturer no longer makes this part, and there's no substitute part

  • Blwr Ags Dr for Goodman GMP100-3 - Part 25150-04S

    #4

    All parts diagram

    Blwr Ags Dr

    Part #25150-04S

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Door Switch for Goodman GMP100-3 - Part B13708-20

    #49

    All parts diagram

    Furnace Door Switch

    Part #B13708-20

    The manufacturer no longer makes this part, and there's no substitute part

Goodman Gas Furnace GMP100-3 FAQs

Replacing a 100,000 BTU gas furnace like the Goodman GMP100-3 typically costs about $4,000 to $9,000 installed in many U.S. homes. Your final price depends most on efficiency level, venting changes, and whether the job needs ductwork, electrical, or gas-line updates; see the owner's manual for model-specific requirements.

Typical installed cost breakdown

These are common line items that drive the total replacement price:

  • New furnace equipment (often the biggest single cost)
  • Labor for removal and installation
  • Venting or flue modifications (especially if changing efficiency class)
  • Thermostat and low-voltage wiring updates
  • Permits and start-up testing
  • Optional ductwork repairs, sealing, or return-air improvements
Cost item Typical share of total Notes
Furnace equipment 40% to 60% Higher AFUE and two-stage/variable-speed costs more
Labor 25% to 40% Access, attic/crawlspace installs, and complexity raise labor
Venting, gas, electrical, permits 10% to 25% Often higher when changing vent type or upsizing gas line
What changes the price the most

A “100,000 BTU” label is only part of the story. These factors usually move the quote up or down:

  • Efficiency (AFUE) and venting type: High-efficiency furnaces often require different vent materials and routing.
  • Blower and comfort features: Variable-speed blowers and multi-stage heat add cost but can improve comfort.
  • Fit and airflow: If the new cabinet size or airflow needs differ, duct transitions or return-air work may be needed.
  • Condition of safety controls: If you are repairing instead of replacing, parts like the board B1809913S or limit 290 1370905S can be involved in no-heat or shutdown issues.
Repair vs. replace: a quick rule of thumb

Use this as a practical decision guide:

  • Repair when the furnace is under ~10 years old and the issue is isolated (ignition, limit switch, blower wheel).
  • Replace when the heat exchanger is compromised, repairs are frequent, or total repair cost is approaching a large share of replacement.
  • Get the size right: 100,000 BTU is common, but correct sizing depends on your home and duct system.
Why it matters

A properly installed, correctly sized furnace runs safer, cycles less, and maintains steadier temperatures. Installation details (venting, combustion air, airflow) often matter as much as the furnace brand.

If you decide to repair first, you can order GMP100-3 replacement parts from the parts list for this model, or search by model number on Sears PartsDirect.

Last updated: February 2026

Yes. A 25-year-old gas furnace is past its typical service life, so we recommend planning to replace it even if it still runs. At this age, efficiency is usually lower and the risk of a no-heat failure rises, especially during peak winter demand.

Typical lifespan and what 25 years means

Most gas furnaces last 15 to 20 years. At 25 years, it is common to see more frequent breakdowns, harder-to-find parts, and higher operating costs.

Common age-related issues

  • Heat exchanger and burner wear that can reduce reliable heat output
  • Ignition and control problems (intermittent starts, short cycling)
  • Blower wear (noise, vibration, weak airflow)
  • Safety switch trips (limit switch opening due to overheating)
  • Rising repair frequency and longer downtime waiting on parts
Repair vs. replace: a quick decision guide

Use this to decide what makes sense for your Goodman GMP100-3.

Situation Usually makes sense to…
Minor repair, furnace otherwise stable Repair and keep running short-term
Repeated no-heat calls in one season Replace
Expensive control or blower repair needed Replace
Comfort issues (uneven heat, long run times) Replace
If you keep it running this season

If you are not replacing immediately, we recommend focusing on the most failure-prone items and airflow.

  • Confirm filter is clean and return vents are open
  • Listen for blower noise or wobble; a worn wheel can reduce airflow
  • Watch for overheating symptoms (burners shut off, blower keeps running)
  • If ignition is inconsistent, the control board is a common culprit
  • Use the wiring diagram and sequence of operation in the GMP100-3 owner’s manual to match symptoms to components

Model-related parts that often come up on older furnaces

Why it matters

A furnace that is beyond its expected lifespan can fail without warning and may cost more to operate. Replacing proactively helps avoid emergency no-heat situations and can improve comfort and heating performance.

For replacement parts you decide to install while you plan an upgrade, order from the parts list for model GMP100-3, or search by model on Sears PartsDirect.

Last updated: February 2026

On a Goodman GMP100-3 gas furnace, error code 3 (three flashes) commonly points to a pressure switch problem, most often a pressure switch circuit stuck open. In practice, that means the furnace is not proving proper draft, so the control board stops ignition for safety. Check the diagnostic chart and wiring diagram in the owner's manual.

What usually causes error code 3

These are the most common, fixable causes we see with pressure switch faults:

  • Blocked pressure switch hose (water, debris, cracks, or kinks)
  • Loose or misrouted hose connections between the inducer housing and pressure switch
  • Vent or intake restriction (snow, leaves, bird nest, sagging vent, condensate blockage)
  • Inducer (draft) blower issue (not starting, weak airflow, noisy wheel, seized motor)
  • Loose wiring at the pressure switch or control board spade terminals
  • Failed pressure switch (does not close when inducer runs)
Quick checks you can do safely

Turn off power to the furnace at the switch or breaker before touching wiring.

  • Confirm the filter is clean and supply/return vents are open (poor airflow can contribute to overheating and nuisance shutdowns).
  • Inspect the rubber pressure hose for cracks, soft spots, water, or blockage; remove and gently clear it.
  • Check the venting for obvious obstructions and make sure joints are secure.
  • Reseat the pressure switch wires and look for burnt or loose terminals.
What the furnace is “looking for” (pressure switch logic)
Furnace step What should happen What triggers code 3
Call for heat Inducer starts Inducer does not run or runs weak
Draft proving Pressure switch closes Switch stays open (draft not proven)
Ignition sequence Igniter and gas valve operate Control locks out ignition for safety
Parts that are often involved

If troubleshooting points to the control not reading the switch correctly, the ignition control can be part of the circuit to inspect.

Why it matters

A pressure switch fault is a safety shutdown designed to prevent operation when the furnace cannot vent combustion gases correctly. Clearing restrictions and confirming proper inducer operation helps restore safe, reliable heat.

You can order replacement parts for your Goodman GMP100-3 from the parts list for this model, or search by model number on Sears PartsDirect.

Last updated: February 2026

A Goodman gas furnace like model GMP100-3 typically lasts 15 to 20 years. Lifespan depends most on annual maintenance, clean airflow (filter and blower), correct gas combustion, and avoiding repeated overheating that trips safety limits.

Typical lifespan ranges (what to expect)

Most homeowners see these timeframes when the furnace is installed correctly and maintained:

Component Typical service life What shortens it fastest
Heat exchanger 15 to 25 years Overheating, restricted airflow, poor combustion
Blower motor and wheel 10 to 20 years Dirty filter, dust buildup, imbalance
Ignition and control electronics 7 to 15 years Power surges, moisture, loose wiring
Limit and rollout switches 10 to 20 years Chronic overheating, venting issues
What helps your GMP100-3 reach the high end of its lifespan
  • Replace or clean the air filter on schedule to keep airflow strong.
  • Keep supply registers and return grilles open and unobstructed.
  • Vacuum dust around the blower area and keep the cabinet clean.
  • Have a yearly inspection to verify safe ignition, flame quality, and venting.
  • Address short cycling quickly; it often points to airflow restriction or a control issue.
Parts that commonly affect reliability

If your furnace is running but acting erratic (no ignition, short cycling, blower issues, or nuisance shutdowns), these model-related parts are often involved:

Why it matters

A furnace that is overheating, short cycling, or struggling to move air can wear out major components sooner and increase energy use. Keeping airflow and safety controls in good shape is the most practical way to protect the heat exchanger and extend overall furnace life.

For maintenance intervals and model-specific procedures, follow the owner's manual. You can also order replacement parts for your Goodman GMP100-3 from the parts list for this model.

Last updated: February 2026

On a Goodman GMP100-3 gas furnace, the most common “failure” is usually a maintenance-related item rather than a major component: a clogged air filter that overheats the furnace, or a dirty flame-sensing circuit that shuts the burners down for safety. Use the owner's manual to match the correct service checks and sequence of operation.

Most common furnace failures (what we see most often)
  • Dirty air filter: restricted airflow can trip a limit switch and stop heat.
  • Flame-sensing problem: a dirty flame sensor or poor grounding can cause short cycling (burners light, then shut off).
  • Ignition/control issue: the ignition control board can fail or lose proper signal timing; on this model, the control is the board B1809913S.
  • Overheat protection opening: a limit switch can open if airflow is low; a common safety device for this model family is the limit 290 1370905S.
  • Thermostat or low-voltage wiring issue: loose connections, broken wires, or a blown low-voltage fuse.
Quick checks before replacing parts
  1. Set thermostat to HEAT and raise setpoint 3 to 5 degrees.
  2. Replace the air filter; confirm all supply registers are open.
  3. Turn power off, then back on at the furnace switch or breaker.
  4. Watch the start-up sequence: inducer, igniter glow, burner ignition, blower start.
  5. If burners light then shut off quickly, focus on flame-sensing and grounding.
Symptom-to-likely-cause guide
What you notice Most likely cause What to do next
Blower runs, no heat Thermostat call issue or control problem Verify thermostat settings and wiring; check control diagnostics per manual
Igniter glows, no flame Gas supply/valve issue or control timing Confirm gas is on; follow manual ignition sequence checks
Flame starts then stops in seconds Flame-sensing circuit issue Clean sensor, check ground, inspect burner flame
Furnace shuts down after a few minutes Overheating, airflow restriction Replace filter, check blower wheel and ducts; verify limit operation
Why it matters

Most “no-heat” calls are caused by airflow restriction or flame-proving shutdowns. Fixing those first prevents unnecessary replacement of high-cost parts like the ignition control board and helps protect the heat exchanger and blower system.

You can order model-matched replacement parts from the parts list for GMP100-3, or search by model number on Sears PartsDirect.

Last updated: February 2026

Symptoms for gas ranges

Main causes: gas supply problem, faulty pressure regulator, clogs in burner or orifice, control system failure, faulty t…

Main causes: burner igniter switch failure, bad spark module, dirty or damaged spark electrode, wiring failure…

Repair guides for gas ranges

How to replace a gas range oven igniter

How to replace a gas range oven igniter

If your gas oven doesn't heat up, the problem could be a faulty oven igniter. These step-by-step instructions guide you …

Repair time and Difficulty

 45 minutes or less
How to replace an oven temperature sensor on a gas range

How to replace an oven temperature sensor on a gas range

See how to replace an oven temperature sensor on a gas range.…

Repair time and Difficulty

 15 minutes or less
How to replace a gas range oven control board

How to replace a gas range oven control board

These step-by-step instructions explain how to replace an oven control board on a gas range…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Air Compressor
Bottom-Mount Refrigerator
Dryer
Garbage Disposal
Gas Range
Gas Walk-Behind Mower
Parts
Refrigerator
Side-By-Side Refrigerator
Top-Mount Refrigerator
Washer
Water Heater
Weight System