Here are the diagrams and repair parts for Goodman CKJ60-1 condensing unit, as well as links to manuals and error code tables, if available.

Goodman CKJ60-1 condensing unit
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for CKJ60-1 Condensing Unit

Goodman Condensing Unit CKJ60-1 FAQs

A 6,000 BTU air conditioner typically costs $15 to $35 per month to run when it’s used about 8 hours per day and electricity is around $0.15 per kWh. Your actual cost depends on the unit’s running watts, daily runtime, and your local rate.

Quick way to estimate your monthly cost

Use this formula:

  • Monthly cost = (Watts ÷ 1000) × hours/day × 30 × $/kWh
  • Most 6,000 BTU window or portable units run around 400 to 650 watts while the compressor is on.

Example cost table (common scenarios)

Running watts Hours/day Rate ($/kWh) Est. monthly cost
450 W 8 0.15 $16.20
600 W 8 0.15 $21.60
600 W 12 0.15 $32.40
650 W 12 0.20 $46.80

What changes the cost the most

  • Thermostat setting (lower setpoints run longer)
  • Outdoor temperature and humidity (more heat load increases runtime)
  • Insulation and air leaks (poor sealing increases run time)
  • Filter and coil cleanliness (restricted airflow raises energy use)
  • Unit efficiency and age (older units typically use more electricity)

How this relates to your Goodman CKJ60-1

The Goodman CKJ60-1 is a central A/C condensing unit, not a 6,000 BTU room A/C. Central systems are much higher capacity, so monthly operating cost is typically higher. If the outdoor unit has trouble starting or runs inconsistently, a weak run capacitor is a common cause.

Parts that can affect starting and run behavior

Part What it can cause when failing
Capacitor CAP050800440RTP Hard starting, humming, fan not spinning
Capacitor 60 CAP050600440RTP Compressor or fan struggles to start, overheating
Capacitor 45 12769 Intermittent starting, reduced performance

Why it matters

Estimating operating cost helps you spot abnormal energy use. If your bill jumps without a weather change, longer runtime from airflow restrictions or a weakening capacitor is often the reason.

Last updated: February 2026

For Goodman model CKJ60-1, the “60” in the model number typically indicates about 60,000 BTU/h of cooling capacity, which equals 5 tons (60,000 ÷ 12,000). We use this same BTU-to-tons method across most central AC condensing units.

Quick tonnage math (BTU to tons)

Use this simple conversion:

  • Find the capacity code in the model number (often 18, 24, 30, 36, 42, 48, 60)
  • Treat it as thousands of BTU/h (example: 36 = 36,000 BTU/h)
  • Divide BTU/h by 12,000
  • The result is the nominal tonnage
Capacity code Approx. BTU/h Approx. tons
24 24,000 2
36 36,000 3
48 48,000 4
60 60,000 5

What to check if the model number is unclear

If the number is missing, worn off, or doesn’t follow the common pattern, these checks help confirm capacity:

  • Look for the data plate on the outdoor condensing unit cabinet
  • Compare the outdoor unit size with the indoor coil/air handler match (mismatches reduce performance)
  • Check the compressor and fan motor nameplate ratings for clues
  • Verify the electrical specs match what a unit of that tonnage typically uses

If you’re troubleshooting cooling issues while confirming capacity, testing electrical components can be part of the process; our how to use a multimeter to test electrical parts video can help you do that safely and correctly.

Why it matters

Correct tonnage affects comfort and efficiency. An oversized unit can short-cycle and leave humidity high; an undersized unit can run constantly and still not keep up on hot days.

Last updated: February 2026

Common problems we see on Goodman central AC condensing units like model CKJ60-1 include not cooling, weak airflow, outdoor unit not starting, buzzing or rattling noises, and intermittent shutdowns. Many issues trace back to power and control parts, dirty coils, or failing start/run components.

Most common symptoms and what they usually point to

  • Outdoor unit will not start: tripped breaker, disconnect issue, thermostat call not reaching the condenser, or a failed contactor/capacitor
  • Runs but does not cool: dirty condenser coil, low refrigerant charge, restricted airflow indoors, or compressor problems
  • Buzzing or chattering at the unit: worn contactor contacts, loose wiring, or failing capacitor
  • Fan runs but compressor does not: weak run capacitor, hard-start issues, or compressor electrical fault
  • Short cycling (starts and stops quickly): overheating from dirty coil, electrical control issues, or refrigerant problems

Parts that commonly fail on outdoor condensing units

These are frequent wear items on many Goodman condensers, and they are also common suspects when the unit will not start or hums.

Part type What it does Common failure signs
Contactor Sends line voltage to compressor and fan clicking/buzzing, pitted contacts, unit will not start
Run capacitor Helps start and run the compressor/fan humming, hard starts, fan or compressor not running
Filter drier Helps keep moisture/debris out of the sealed system restriction symptoms after sealed-system work

If you are diagnosing a no-start or humming issue, the capacitor CAP050800440RTP and capacitor 40 12871 are examples of run capacitors listed for CKJ60-1, and the contactor is another common electrical failure point.

Safe, practical checks you can do first

  • Set thermostat to cool and lower setpoint; confirm indoor blower is running
  • Check the breaker and outdoor disconnect (power must be present)
  • Clear debris and keep at least 18 to 24 inches of space around the condenser
  • Inspect for obvious burnt wires or loose connections (power off)
  • If the unit hums but will not start, test the capacitor with a meter (power off and discharged)

For electrical testing basics, use how to use a multimeter to test electrical parts video.

Why it matters

Catching a weak capacitor or failing contactor early helps prevent repeated hard starts, nuisance shutdowns, and added strain on the compressor, which is the most expensive component in the outdoor unit.

Last updated: February 2026

A Goodman central air conditioner condensing unit like model CKJ60-1 typically lasts 12 to 15 years. With correct installation, clean airflow, and yearly service, many units reach 15 to 20 years before major repairs (like a compressor or coil issue) become more likely.

What affects lifespan the most

  • Installation quality: correct refrigerant charge, proper airflow, and correct electrical sizing
  • Maintenance: keeping the outdoor coil clean and the indoor filter changed regularly
  • Runtime and climate: long cooling seasons and extreme heat shorten life
  • Electrical health: stable voltage and tight wiring connections reduce contactor and capacitor wear
  • Refrigerant system condition: leaks and moisture contamination accelerate failures

Typical lifespan ranges (what to expect)

Condition Typical lifespan What you usually see
Minimal maintenance 8 to 12 years higher energy use, more hard-starts, more service calls
Average maintenance 12 to 15 years occasional repairs (capacitor, contactor)
Excellent maintenance 15 to 20 years fewer breakdowns, steadier cooling performance

Repairs that commonly show up as a unit ages

These are common wear items on outdoor condensing units and often cost far less than replacing the whole system:

  • Run capacitor issues (humming, fan not starting, compressor struggles to start)
  • Contactor problems (outdoor unit will not turn on, chattering, burned contacts)
  • Wiring and connection problems (overheating, intermittent operation)

If you are troubleshooting electrical symptoms, our how to use a multimeter to test electrical parts video can help you test safely and accurately.

Why it matters

Knowing the expected lifespan helps you decide whether to invest in a repair (like a capacitor or contactor) versus planning for replacement, especially if cooling performance is dropping or repairs are becoming frequent.

Last updated: February 2026

Symptoms for band saws

Choose a symptom to see related band saw repairs.

Main causes: dull blade, improper feeding, loose blade tension, not using a work piece guide…

Main causes: lack of electrical power, broken power cord, bad on/off switch, faulty drive motor…

Main causes: broken saw blade, bad drive belt, damaged rubber tire…

Main causes: dull blade, using the wrong type of blade, weak drive motor…

Main causes: dull blade, using the wrong type of blade, feeding work piece to quickly, loose blade tension…

Main causes: angle indicator needs adjustment, dull blade…

Main causes: damaged rubber tire, worn wheel bearings, loose blade tension, dull saw blade…

Repair guides for band saws

These step-by-step repair guides will help you safely fix what’s broken on your band saw.

How to replace a band saw blade

How to replace a band saw blade

If the saw blade is dull or damaged and isn't cutting cleanly, replace the blade following these steps.…

Repair time and Difficulty

 15 minutes or less
How to replace a band saw drive belt

How to replace a band saw drive belt

If the motor runs but the blade doesn't move, it could be that the drive belt is broken. Here's how to replace it.…

Repair time and Difficulty

 15 minutes or less
How to replace a band saw on-off switch

How to replace a band saw on-off switch

If the switch won't turn the band saw on or off, it could be defective. Replace the switch, using these steps.…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your central air conditioners

Use the advice and tips in these articles and videos to get the most out of your band saw.

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Air Handler
Carpet Cleaner
Dishwasher
Dryer
Electric Range
Front-Engine Lawn Tractor
Gas Cooktop
Gas Snowblower
Parts
Power Sander
Refrigerator
Sewing Machine
Snowblower
Table Saw
Washer