Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Goodman CK18-1 air conditioner heat pump outside unit

Goodman CK18-1 air conditioner heat pump outside unit Parts

Here are the diagrams and repair parts for Goodman CK18-1 air conditioner heat pump outside unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for CK18-1 Air Conditioner Heat Pump Outside Unit

  • Central Air Conditioner Condenser Fan Motor for Goodman CK18-1 - Part B13400251S

    Main asy diagram

    Fan Motor

    Part #B13400251

    Replaced by #B13400251S

    Info Icon
    Manufacturer substitution
    This part replaces B13400251. Substitute parts can look different from the original.
    In Stock
    $293.96
    $12.00 OFF Phone Price : $305.96Info Icon
    Minus Item
    Qty
    Plus Item
  • Grille Inlet 22.5in for Goodman CK18-1 - Part B1259522

    Main asy diagram

    Grille Inlet 22.5in

    Part #B1259522

    The manufacturer no longer makes this part, and there's no substitute part

  • Fan Blade for Goodman CK18-1 - Part B1086756

    Main asy diagram

    Fan Blade

    Part #B1086756

    The manufacturer no longer makes this part, and there's no substitute part

  • Compressor for Goodman CK18-1 - Part B9266226

    Main asy diagram

    Compressor

    Part #B9266226

    The manufacturer no longer makes this part, and there's no substitute part

  • Coil Condenser 22.5x60 for Goodman CK18-1 - Part 1265000

    Main asy diagram

    Coil Condenser 22.5x60

    Part #1265000

    The manufacturer no longer makes this part, and there's no substitute part

  • Pan-bottom for Goodman CK18-1 - Part 1787209P

    Main asy diagram

    Pan-bottom

    Part #1787209P

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel Acce for Goodman CK18-1 - Part 1787706P

    Main asy diagram

    Panel Acce

    Part #1787706P

    The manufacturer no longer makes this part, and there's no substitute part

  • Contactor, 25 Amp, 3 Pole (ph036-3a, Ph048-3a, Ph048-5c, Ph060-3c, Ph060-5c) for Goodman CK18-1 - Part B1360315

    Main asy diagram

    Contactor, 25 Amp, 3 Pole (ph036-3a, Ph048-3a, Ph048-5c, Ph060-3c, Ph060-5c)

    Part #B1360315

    The manufacturer no longer makes this part, and there's no substitute part

Goodman Air Conditioner Heat Pump Outside Unit CK18-1 FAQs

For the Goodman CK18-1 outdoor air conditioner unit, the “18” in the model number typically indicates about 18,000 BTU/hr of cooling, which equals 1.5 tons (since 1 ton = 12,000 BTU/hr). Confirm the exact capacity on the unit data plate or in the CK18-1 owner's manual.

Quick conversion (BTU to tons)

Cooling capacity Equivalent tons
12,000 BTU/hr 1.0 ton
18,000 BTU/hr 1.5 tons
24,000 BTU/hr 2.0 tons

How we recommend confirming tonnage for CK18-1

  • Check the outdoor unit rating label for “Cooling capacity” or “BTU/h”
  • Look for AHRI match information if your system is a matched condenser + indoor coil
  • Verify the model number characters exactly (CK18-1 vs similar CKL18 variants)
  • Use the CK18-1 owner's manual to cross-check the rated capacity and electrical specs

Why it matters

Correct tonnage affects comfort and efficiency. An oversized system can short-cycle and leave humidity high; an undersized system can run constantly and still not keep up on hot days.

If the unit runs but cooling feels weak, the issue is often airflow, electrical, or a failing start/run component rather than “lost tonnage.” On this model, a common electrical wear item is the dual run capacitor; if testing shows it is out of spec, replace it with the correct rating such as the Goodman Goodman dual capac 25/5 mfd 370v B94576000 when it matches your unit label.

Last updated: January 2026

Most Goodman central AC outdoor units like model CK18-1 typically last 12 to 15 years. With correct installation, clean airflow, and yearly service, it’s common to reach 15 to 20 years before major component wear (compressor, fan motor, capacitor) makes replacement more cost-effective.

Typical lifespan ranges (what to expect)

Lifespan depends more on installation quality and operating conditions than brand name alone.

Scenario Typical lifespan What usually fails first
Minimal maintenance, dirty coil, restricted airflow 8 to 12 years Capacitor, contactor, fan motor
Normal maintenance (annual check, clean coil) 12 to 15 years Capacitor, fan motor
Excellent maintenance, mild climate, correct sizing 15 to 20 years Compressor or refrigerant-related issues

What shortens the life of an outdoor AC unit

  • Dirty condenser coil causing high head pressure and overheating
  • Low airflow from a clogged indoor filter or blocked return vents
  • Oversized or undersized system (short cycling or long run times)
  • Loose electrical connections and voltage issues
  • Salt air, lawn chemicals, or constant debris around the cabinet

Maintenance that helps you get the full lifespan

We recommend these practical steps for a Goodman outdoor unit:

  • Replace or clean the indoor air filter regularly (often every 1 to 3 months)
  • Keep 18 to 24 inches of clearance around the outdoor unit
  • Rinse the outdoor coil gently (power off first) to remove lint and grass
  • Schedule a yearly HVAC tune-up to check refrigerant charge and electrical readings
  • If the unit struggles to start or the fan hums, test the capacitor and wiring

A common wear item is the dual run capacitor; for this model’s parts list, see the Goodman dual capac 25/5 mfd 370v B94576000.

Why it matters

Once an AC unit gets into the 12 to 15-year range, small issues (weak capacitor, dirty coil, worn fan motor) can snowball into compressor stress. Preventive maintenance usually costs far less than repeated no-cool breakdowns.

For model-specific service and wiring details, use the CK18-1 manual.

Last updated: January 2026

To check the AC model number on a Goodman CK18-1 outdoor unit, we look for the rating plate or data label on the cabinet. The label lists the model number (CK18-1) and usually the serial number, electrical ratings, and refrigerant information.

Where to look on a Goodman outdoor unit

Check these common spots on an air conditioner heat pump outside unit:

  • On the side panel of the cabinet (most common)
  • Inside the service panel where the electrical components are (after power is off)
  • Near the refrigerant line connections (suction and liquid lines)
  • On the inside of the access door or control box cover
  • On the base pan edge or inside the corner of the cabinet

What the label typically shows

Most outdoor-unit data labels include:

  • Model number (example: CK18-1)
  • Serial number (used to identify production date and exact build)
  • Voltage and minimum circuit ampacity (MCA)
  • Maximum overcurrent protection (breaker or fuse size)
  • Refrigerant type and factory charge
Label item What it’s used for Why you need it
Model number Identifies the unit family Ensures parts match the correct unit
Serial number Identifies the exact build Helps confirm compatible replacements
Electrical ratings Power requirements Prevents incorrect capacitor/contactor selection

Why it matters

For Goodman CK18-1 repairs, the model and serial number help us match the correct parts and specs before troubleshooting issues like a hard-start, fan not running, or compressor not starting.

Helpful next steps

Last updated: January 2026

Common problems with a Goodman CK18-1 outdoor air conditioner or heat pump unit include not cooling well, the outdoor fan not running, breaker trips, icing, and unusual buzzing or rattling; the most frequent causes are airflow restrictions, dirty coils, and electrical component wear such as a weak run capacitor.

Most common symptoms and likely causes

  • Weak or warm air indoors: clogged return filter, blocked supply vents, dirty indoor coil, low refrigerant
  • Outdoor unit runs but cools poorly: dirty condenser coil, restricted airflow around the unit, failing capacitor
  • Outdoor fan not spinning: failed dual run capacitor, bad fan motor, loose wiring
  • Unit will not start: tripped breaker, blown fuse, failed contactor, failed capacitor
  • Ice on lines or coil: low airflow (filter/coil), low refrigerant, thermostat issues
  • Noises (buzzing, clicking, rattling): loose panels, debris in fan, failing contactor, failing motor bearings

Quick checks we recommend first (safe, no tools)

  • Set thermostat to Cool and lower setpoint 3 to 5 degrees; confirm indoor blower is running.
  • Replace or clean the return air filter (a top cause of icing and poor cooling).
  • Clear vegetation and debris; keep at least 24 inches of open space around the outdoor unit.
  • Look for obvious issues: damaged insulation on the refrigerant line, loose access panels, or heavy dirt on the coil.
  • If the breaker trips repeatedly, leave it off and move to the service section below.

When a part is commonly involved

A weak dual run capacitor is a frequent cause of hard starting, humming, or an outdoor fan that will not spin.

Symptom Common part involved What you may notice
Outdoor fan will not start Dual run capacitor Humming, fan blade needs a push (do not do this)
Unit clicks but will not run Contactor or capacitor Rapid clicking, intermittent starts
Breaker trips on startup Capacitor, compressor, wiring Trips immediately or within seconds

If you are diagnosing a start or fan issue, match the microfarad (MFD) rating and voltage to the original part; for this model’s common capacitor option, see Goodman Goodman dual capac 25/5 mfd 370v B94576000.

Why it matters

Airflow and electrical issues can look similar at the thermostat, but the fix is very different. Starting with filter, coil cleanliness, and basic power checks prevents unnecessary parts replacement and helps protect the compressor.

Where to find model-specific specs

For wiring diagrams, electrical ratings, and service procedures for the Goodman CK18-1, use the CK18-1 owner’s manual.

Last updated: January 2026

Most common symptoms to help you fix your refrigerators

Choose a symptom to see related refrigerator repairs.

Main causes: leaky door gasket, defrost system failure, evaporator fan not running, dirty condenser coils, condenser fan…

Main causes: control board or cold control failure, broken compressor start relay, compressor motor failure, defrost tim…

Main causes: blocked vents, defrost system problems, evaporator fan failure, dirty condenser coils, bad sensors, condens…

Main causes: blocked air vents, compressor problems, condenser or evaporator fan not working, control system failure, se…

Main causes: water valve leaking, frozen or broken defrost drain tube, overflowing drain pan, cracked water system tubin…

Main causes: damaged door seal, faulty defrost sensor or bi-metal thermostat, broken defrost heater, bad defrost timer o…

Things to do: clean condenser coils, replace the water filter, clean the interior, adjust doors to prevent air leaks, cl…

Main causes: jammed ice cubes, broken ice maker assembly, dirty water filter, kinked water line, bad water valve, freeze…

Most common repair guides to help fix your refrigerators

These step-by-step repair guides will help you safely fix what’s broken on your refrigerator.

How to replace a refrigerator temperature control board

How to replace a refrigerator temperature control board

If the temperature in your refrigerator doesn't match the temperature you set, the problem could be the temperature cont…

Repair time and Difficulty

 30 minutes or less
How to replace a refrigerator water valve

How to replace a refrigerator water valve

Replace the water valve that feeds water to the ice maker and water dispenser if it no longer controls the flow of water…

Repair time and Difficulty

 15 minutes or less
How to clean refrigerator condenser coils

How to clean refrigerator condenser coils

Help your refrigerator run more efficiently by cleaning the condenser coils. It's easy and takes just a few minutes.…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your refrigerators

Use the advice and tips in these articles and videos to get the most out of your refrigerator.

How to Replace the Water Filter in a Universal/Multiflex Refrigerator

How to Replace the Water Filter in a Universal/Multiflex Refrigerator

Learn how easy replacing the water filter in a Universal/Multiflex refrigerator is.…

How to Replace the Water Filter in a KitchenAid Refrigerator

How to Replace the Water Filter in a KitchenAid Refrigerator

Discover how easy it is to replace the water filter in your KitchenAid refrigerator.…

Troubleshooting a refrigerator not cooling video

Troubleshooting a refrigerator not cooling video

Learn what to check if the inside of your fridge is wayyyy too warm.…

Parts & More

Air Compressor
Band Saw
Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Line Trimmer
Gas Range
Gas Water Heater
Lawn Edger
Line Trimmer
Parts
Side-By-Side Refrigerator
Trash Compactor
Washer
Weight System
Wet/Dry Vacuum