Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Sears 867736212 gas-fired direct vent wall furnace

Sears 867736212 gas-fired direct vent wall furnace Parts

Here are the diagrams and repair parts for Sears 867736212 gas-fired direct vent wall furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 867736212 Gas-Fired Direct Vent Wall Furnace

  • Shield for Sears 867736212 - Part 504308

    Unit parts diagram

    Shield

    Part #504308

    The manufacturer no longer makes this part, and there's no substitute part

  • Cover for Sears 867736212 - Part 504507

    Unit parts diagram

    Cover

    Part #504507

    The manufacturer no longer makes this part, and there's no substitute part

  • Plate for Sears 867736212 - Part 504732

    #NI

    All parts diagram

    Plate

    Part #504732

    The manufacturer no longer makes this part, and there's no substitute part

  • Cover for Sears 867736212 - Part 504506

    Unit parts diagram

    Cover

    Part #504506

    The manufacturer no longer makes this part, and there's no substitute part

  • Door Knob for Sears 867736212 - Part 39238

    Unit parts diagram

    Door Knob

    Part #39238

    The manufacturer no longer makes this part, and there's no substitute part

  • Cap Vent for Sears 867736212 - Part 47879

    Unit parts diagram

    Cap Vent

    Part #47879

    The manufacturer no longer makes this part, and there's no substitute part

  • Wire for Sears 867736212 - Part 500370

    #NI

    All parts diagram

    Wire

    Part #500370

    The manufacturer no longer makes this part, and there's no substitute part

  • Support for Sears 867736212 - Part 504241

    Unit parts diagram

    Support

    Part #504241

    The manufacturer no longer makes this part, and there's no substitute part

  • Cup Washer for Sears 867736212 - Part 39632

    Unit parts diagram

    Cup Washer

    Part #39632

    The manufacturer no longer makes this part, and there's no substitute part

  • Orifice for Sears 867736212 - Part 28999

    Unit parts diagram

    Orifice

    Part #28999

    The manufacturer no longer makes this part, and there's no substitute part

Sears Gas-Fired Direct Vent Wall Furnace 867736212 FAQs

For your Sears gas-fired direct vent wall furnace, the model number is typically printed on a rating plate (data tag) attached to the furnace cabinet. On model 867736212, check inside the front access panel first, then check the cabinet side or near the burner compartment.

Where to look on a wall furnace

Most direct vent wall furnaces place the rating plate in one of these spots:

  • Inside the front access panel on the cabinet wall
  • Near the burner compartment or gas valve area
  • On the side of the cabinet (sometimes visible without removing panels)
  • Along the lower front area behind the grille or cover
  • Occasionally on the outside edge of the cabinet near the mounting frame

Safe steps to find and record the model number

Before you remove any panel, use basic safety steps so you can read the tag clearly and avoid damaging wiring.

  • Turn off electrical power to the furnace at the breaker
  • Let the furnace cool if it has been running
  • Remove the front cover or access panel (usually a few screws)
  • Locate the rating plate and write down the full model number and serial number
  • Take a clear photo of the tag for parts lookup and service calls

What the label usually includes (and what to copy)

Use the exact characters shown on the tag. For parts ordering, the full model number matters.

Label item What it’s used for Example of what to record
Model number Matching parts diagrams and parts 867736212
Serial number Production run details Copy exactly as shown
Input rating (BTU) Sizing and troubleshooting Copy the BTU value
Gas type Correct fuel setup Natural gas or LP

Why it matters

We use the model number to match the correct furnace parts, such as ignition and safety components. Even small model-number differences can change which parts fit and how the furnace is wired.

If your rating plate is damaged or missing, use how to find your appliance model number (and what it means for parts) to identify common tag locations and what information to capture.

Last updated: January 2026

Yes. A 25-year-old Sears gas-fired direct vent wall furnace (model 867736212) is past the typical furnace lifespan (about 15 to 20 years), so replacement is the practical choice for reliability, efficiency, and safer operation during cold weather.

When replacement is the right call

We recommend planning a replacement if you notice any of these common age-related issues:

  • Frequent service calls or repeated ignition/pilot problems
  • Rising heating bills compared with prior winters
  • Uneven heat, short cycling, or trouble maintaining set temperature
  • Sooting, unusual burner flame behavior, or persistent odors
  • Corrosion, rattling, or excessive vibration from the cabinet or venting

Repair vs. replace: a quick comparison

Situation Repair makes sense Replace makes sense
Furnace age Under ~15 years 25 years (end-of-life)
Breakdowns Rare, simple fixes Repeated failures or hard-to-source parts
Operating cost Stable Bills climbing year over year
Safety confidence Strong, consistent operation Ongoing combustion or venting concerns

If you are trying to keep it running short-term

If you need heat while you plan a replacement, focus on the most common no-heat items for older gas appliances:

  • Confirm thermostat settings and power to the unit
  • Inspect and clean the pilot area and burner compartment (dust and lint matter)
  • Check the thermocouple connection and condition; a weak thermocouple can shut off gas to the pilot
  • If your unit uses a pilot tube assembly, inspect fittings for looseness and damage

If you need parts that match what is listed for this model, start with ferrule nut 100108370 and how to find your appliance model number (and what it means for parts).

Why it matters

At 25 years old, the biggest risk is winter downtime: older furnaces tend to fail when demand is highest, and repairs can become less cost-effective as efficiency drops and parts availability narrows.

Last updated: January 2026

The three most common residential furnace types are gas, electric, and oil, grouped by the fuel they use to create heat. For Sears model 867736212 (a gas-fired direct vent wall furnace), the “type” is gas; service and parts selection focus on combustion, venting, and safety controls.

Quick breakdown of the 3 furnace types

  • Gas furnace (natural gas or propane): Uses a burner and ignition or pilot system; requires proper venting and combustion air.
  • Electric furnace: Uses electric heating elements; no combustion or flue gases, but typically higher electrical demand.
  • Oil furnace: Burns heating oil; common where gas service is limited and needs an oil tank and burner maintenance.

Another “type” you may hear: how the furnace stages heat

These terms describe how the furnace controls output, regardless of fuel:

Control style What it does Typical comfort result
Single-stage Full heat or off More temperature swing
Two-stage High or low heat More even temperatures
Modulating Many small adjustments Steadiest comfort and quieter operation

Why it matters for Sears 867736212 parts and troubleshooting

Fuel type determines the components you diagnose first. On a gas-fired direct vent wall furnace like 867736212, no-heat or pilot-related symptoms often involve the pilot assembly, gas valve safety circuit, and venting.

  • If a pilot will not stay lit, inspect the pilot flame and safety sensing circuit.
  • If you see a leak or looseness at a pilot tube connection, inspect the fitting and sealing surfaces.
  • If you are checking electrical safety controls, test with the right meter and keep power off during handling.

A common connection component you may see in pilot tube service is the ferrule nut 100108370.

Last updated: January 2026

Symptoms for gas cooktops

Main causes: burner igniter switch failure, bad spark module, dirty or damaged spark electrode, wiring failure, lack of …

Main causes: stuck burner igniter switch, wet igniter switch contacts, faulty spark module…

Main causes: gas supply problem, faulty pressure regulator, clogs in burner or orifice, burner valve failure…

Repair guides for gas cooktops

How to replace a spark module on a gas cooktop

How to replace a spark module on a gas cooktop

No flame on your gas cooktop? Installing a new spark module could be the fix you need.…

Repair time and Difficulty

 30 minutes or less
How to replace a spark igniter switch on a gas cooktop

How to replace a spark igniter switch on a gas cooktop

Follow these step-by-step instructions to fix the surface burner ignition system on your gas cooktop by replacing the sp…

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Parts