Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

York P3URD10N05501 upflow natural gas furnace Parts

Here are the diagrams and repair parts for York P3URD10N05501 upflow natural gas furnace, as well as links to manuals and error code tables, if available.

York P3URD10N05501 upflow natural gas furnace
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for P3URD10N05501 Upflow Natural Gas Furnace

  • Motor for York P3URD10N05501 - Part 373-14249-701

    Blower assembly diagram

    Motor

    Part #373-14249-701

    The manufacturer no longer makes this part, and there's no substitute part

  • Capacitor for York P3URD10N05501 - Part 024-20084-700

    Blower assembly diagram

    Capacitor

    Part #024-20084-700

    The manufacturer no longer makes this part, and there's no substitute part

  • Channel, Toe Plate for York P3URD10N05501 - Part 073-12062-702

    Heat exchange diagram

    Channel, Toe Plate

    Part #073-12062-702

    The manufacturer no longer makes this part, and there's no substitute part

  • Pan Base for York P3URD10N05501 - Part 073-12061-702

    Heat exchange diagram

    Pan Base

    Part #073-12061-702

    The manufacturer no longer makes this part, and there's no substitute part

  • Grommet for York P3URD10N05501 - Part 028-11284-000

    Burner orifice diagram

    Grommet

    Part #028-11284-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Condensation Pan for York P3URD10N05501 - Part 028-12452-000

    Heat exchange diagram

    Condensation Pan

    Part #028-12452-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Bracket for York P3URD10N05501 - Part 073-17403-000

    Burner orifice diagram

    Bracket

    Part #073-17403-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Coil for York P3URD10N05501 - Part 073-12127-002

    Heat exchange diagram

    Coil

    Part #073-12127-002

    The manufacturer no longer makes this part, and there's no substitute part

  • Wrapper, Cabinet for York P3URD10N05501 - Part 373-12056-702

    Heat exchange diagram

    Wrapper, Cabinet

    Part #373-12056-702

    The manufacturer no longer makes this part, and there's no substitute part

  • Switch, Air Pressure for York P3URD10N05501 - Part 024-26038-000

    Blower assembly diagram

    Switch, Air Pressure

    Part #024-26038-000

    The manufacturer no longer makes this part, and there's no substitute part

York Upflow Natural Gas Furnace P3URD10N05501 FAQs

Yes. A 25-year-old York furnace like model P3URD10N05501 is past the typical furnace lifespan (about 15 to 20 years), so replacement is the smart move for reliability, efficiency, and safety. At this age, the risk of expensive breakdowns rises sharply, especially during peak heating season.

When replacement is the best choice

If you see any of the issues below, replacement is the practical path instead of putting more money into repairs:

  • Frequent repairs or repeated no-heat calls
  • Rising gas bills or uneven heating from room to room
  • Short cycling (turning on and off too often)
  • Excessive noise (rumbling, booming, or squealing)
  • Rust, soot, or persistent “hot metal” odors around the furnace
  • Trouble keeping the pilot or ignition system running consistently

Repair vs. replace: a quick decision guide

Use this as a simple way to decide where your money goes.

Situation Usually makes sense to… Why
Minor electrical issue (like a weak blower motor run capacitor) Repair Low-cost part, quick fix
Multiple parts failing over a season Replace Repairs stack up fast
Heat exchanger or major combustion concerns Replace High cost and high risk
Comfort and efficiency are poor even after tune-ups Replace Newer furnaces heat more evenly and efficiently

If you are troubleshooting a blower that hums, struggles to start, or overheats, a failed run capacitor is a common cause; the Capacitor 12907 is one of the model-specific parts listed for P3URD10N05501.

Why it matters

A furnace that is well beyond its expected service life can fail without warning, and older systems typically cost more to run. Replacing proactively helps avoid emergency no-heat situations and can improve comfort, airflow, and temperature consistency.

If you replace it, what to do first

  • Confirm the exact model number from the furnace rating plate (you have P3URD10N05501)
  • Compare the cost of the last 1 to 2 years of repairs against replacement
  • Plan replacement before the coldest weeks, when breakdowns are most disruptive
  • Keep the old furnace running safely until replacement by changing filters regularly and keeping vents clear

Last updated: February 2026

Your York furnace model number is the identifier we use to match the correct parts and diagrams to your exact unit. For model P3URD10N05501, the full string typically encodes the product series, fuel type, airflow configuration, and heating capacity; the exact meaning of each character depends on York’s coding.

Where to find the model number (and why it matters)

We recommend reading the model number directly from the furnace rating plate, then using that exact text when ordering parts.

  • Look for a data label inside the burner compartment or on the inside of the access panel
  • Copy the model number and serial number exactly (letters, numbers, and any dashes)
  • Use the model number to pull the correct parts list for P3URD10N05501
  • Use the serial number to identify the manufacturing date code (format varies by brand)
  • If the label is worn, take a clear photo and zoom in to confirm characters

How York model numbers are usually structured

York model numbers are commonly a series of letters and numbers that describe the furnace family and key specs. While the exact decoding varies, here is the practical way to interpret what you see.

What you see in the model number What it usually indicates How we use it
Letter prefix (example: “P…”) Product series/family Helps match the correct diagrams
Middle letters (example: “URD”) Configuration/feature set Narrows compatible assemblies
Number group (example: “10”, “055”) Size or capacity family Helps confirm correct motor/controls
Ending digits Revision/version Ensures the right replacement part

Tips to avoid ordering the wrong part

  • Match the model number exactly; one character difference can change the parts list
  • Confirm the part by description and ID before checkout
  • For motor-related issues, a run capacitor is a common match point; see the capacitor 12907 if your parts list calls for it

Why it matters

Using the exact York model number (P3URD10N05501) prevents mismatched parts, reduces downtime, and helps ensure safe, correct fit for components like blower motor electrical parts and controls.

Last updated: February 2026

A 60,000 BTU furnace like the York P3URD10N05501 typically heats about 1,200 to 2,000 sq. ft. The real coverage depends on your climate zone, insulation, air leakage, window quality, and ceiling height; colder climates and drafty homes land on the lower end.

Quick sizing ranges (what 60,000 BTU usually covers)

Use these as practical planning numbers, not a final sizing decision:

  • Warm or mild climates, good insulation: ~1,700 to 2,000 sq. ft.
  • Mixed climates, average insulation: ~1,400 to 1,700 sq. ft.
  • Cold climates or older, leaky homes: ~1,200 to 1,500 sq. ft.
  • High ceilings, lots of glass, or poor ductwork: expect less coverage
  • Tight, well-sealed homes: expect more coverage
Home and climate situation Typical sq. ft. a 60,000 BTU furnace can heat
Mild climate + good insulation 1,700 to 2,000
Average conditions 1,400 to 1,700
Cold climate or poor insulation 1,200 to 1,500

Why the square footage estimate can be wrong

Square footage rules of thumb ignore the biggest drivers of heat loss. These factors often change the required furnace size more than the floor plan does:

  • Insulation levels in attic, walls, and basement
  • Air sealing (drafts around doors, rim joists, recessed lights)
  • Window type and how much glass faces north
  • Duct leakage and ducts running through unconditioned spaces
  • Ceiling height and open stairwells

The sizing step that prevents comfort problems

For the most accurate result, we size by a load calculation (often called Manual J). That calculation matches furnace output to your home’s heat loss so you avoid common issues:

  • Oversized furnace: short cycling, temperature swings, noisier operation
  • Undersized furnace: long run times, cold rooms during extreme weather

Parts note for this model

If you are troubleshooting blower performance or motor starting issues on the P3URD10N05501, a weak run capacitor is a common electrical failure point; match ratings exactly when replacing. The parts list for this model includes the capacitor 12907.

Last updated: February 2026

Yes; a 95% AFUE furnace is worth the extra money when you have a long heating season and plan to stay in the home long enough to benefit from lower gas use. For a York upflow natural gas furnace like model P3URD10N05501, the decision comes down to fuel savings versus higher installation complexity.

Quick way to decide

A 95% furnace is the better value when most of these are true:

  • You expect to live in the home 8+ years.
  • Your furnace runs a lot (cold winters, long heating season).
  • You are replacing an older 80% AFUE furnace.
  • You can run approved intake and exhaust venting to the outdoors.
  • You have a plan for condensate drainage (required on 90%+ condensing furnaces).

80% vs 95%: what changes

High-efficiency (condensing) furnaces pull more heat out of the exhaust, which is why they need different venting and a drain.

Feature 80% AFUE (non-condensing) 95% AFUE (condensing)
Heat from 100,000 BTU of gas About 80,000 BTU About 95,000 BTU
Venting (typical) Metal flue PVC/CPVC/PP (per code)
Condensate drain No Yes
Install cost/complexity Lower Higher

Payback you can expect

Most homeowners see payback in about 6 to 10 years, driven mainly by:

  • Local gas cost
  • Climate and runtime
  • Home insulation and air leakage
  • Installed price difference between 80% and 95%

Why it matters

A 95% furnace can cut heating fuel use and often improves comfort because it can run longer at lower output. The install details (venting and condensate handling) determine whether you get reliable performance.

Parts note for troubleshooting

If you are diagnosing a blower that hums, starts slowly, or overheats, a weak run capacitor is a common cause. For this model, we list the capacitor 12907 (part number 024-20045-700).

Last updated: February 2026

Repair guides for front-engine lawn tractors

How to replace a blade clutch cable on a riding lawn mower

How to replace a blade clutch cable on a riding lawn mower

If the blades don't spin on your riding mower when you shift the lever, the blade clutch cable could be broken. Here’s h…

Repair time and Difficulty

 30 minutes or less
How to replace a ground drive belt on a riding lawn mower

How to replace a ground drive belt on a riding lawn mower

Replace the ground drive belt if it's broken or too worn to spin the transaxle pulley.…

Repair time and Difficulty

 45 minutes or less
How to replace a riding lawn mower blade drive belt

How to replace a riding lawn mower blade drive belt

Replace the blade drive belt if it's broken or won't spin the cutting blades because of wear.…

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Dishwasher
Dryer
Electric Range
Gas Range
Gas Water Heater
Laundry Center
Room Air Conditioner
Side-By-Side Refrigerator
Top-Mount Refrigerator
Vhs Players & Vcrs