Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

York D3CE036A25 heating & cooling unit Parts

Here are the diagrams and repair parts for York D3CE036A25 heating & cooling unit, as well as links to manuals and error code tables, if available.

York D3CE036A25 heating & cooling unit
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for D3CE036A25 Heating & Cooling Unit

  • Motor Run Capacitor for York D3CE036A25 - Part 12907

    Capacitor

    Part #024-20045-700

    Replaced by #12907

    Info Icon
    Manufacturer substitution
    This part replaces 024-20045-700. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.76
    17% OFF Phone Price : $5.76Info Icon
    Minus Item
    Qty
    Plus Item
  • Belt for York D3CE036A25 - Part 028-09571-000

    Belt drive option diagram

    Belt

    Part #028-09571-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Hous Blower for York D3CE036A25 - Part 026-25539-000

    #35

    All parts diagram

    Hous Blower

    Part #026-25539-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Hermetic Scroll Compressor for York D3CE036A25 - Part 015-02554-001

    #1A

    All parts diagram

    Hermetic Scroll Compressor

    Part #015-02554-001

    The manufacturer no longer makes this part, and there's no substitute part

  • Lug Ground for York D3CE036A25 - Part 025-21798-000

    #25

    All parts diagram

    Lug Ground

    Part #025-21798-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Rail, End (evap End) for York D3CE036A25 - Part 063-87544-001

    #74

    All parts diagram

    Rail, End (evap End)

    Part #063-87544-001

    The manufacturer no longer makes this part, and there's no substitute part

  • Accessories - Electrical (cont) Electric Heater (600v) 10.6kw (575-3-60) for York D3CE036A25 - Part 2CE04501058

    #NI

    All parts diagram

    Accessories - Electrical (cont) Electric Heater (600v) 10.6kw (575-3-60)

    Part #2CE04501058

    The manufacturer no longer makes this part, and there's no substitute part

  • Contactor for York D3CE036A25 - Part 024-20424-000

    #17A

    All parts diagram

    Contactor

    Part #024-20424-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Cover Duct for York D3CE036A25 - Part 363-87667-000

    #57

    All parts diagram

    Cover Duct

    Part #363-87667-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Accessories - Electrical (cont) Electric Heater (480v) 10.1kw (460-3-60) for York D3CE036A25 - Part 2CE04501046

    #NI

    All parts diagram

    Accessories - Electrical (cont) Electric Heater (480v) 10.1kw (460-3-60)

    Part #2CE04501046

    The manufacturer no longer makes this part, and there's no substitute part

Most common symptoms to help you fix your heating & cooling combined units

Choose a symptom to see related heating and air conditioning system repairs.

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Thermostat problem, clogged air filter, burner failure…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: Errant thermostat settings, lack of power, bad interlock switches, lack of exhaust ventilation, wiring fail…

Dirty flame sensor, failed flame sensor, damaged burner, bad high limit switch…

Most common repair guides to help fix your heating & cooling combined units

These step-by-step repair guides will help you safely fix what’s broken on your HVAC system.

How to unclog the air conditioner drain line

How to unclog the air conditioner drain line

The condensate drain line for your central air conditioner can clog with mold and mildew. Water will back up and start d…

Repair time and Difficulty

 15 minutes or less
How to replace the furnace flame sensor

How to replace the furnace flame sensor

The flame sensor detects when furnace burner flames are lit. You may need to replace the flame sensor if flames only sta…

Repair time and Difficulty

 15 minutes or less
How to replace a heating and air conditioning system thermostat

How to replace a heating and air conditioning system thermostat

The control thermostat for your HVAC system can stop working. This repair guide shows how to replace it.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your heating & cooling combined units

Use the advice and tips in these articles and videos to get the most out of your HVAC system.

Should I replace my gas furnace with an electric heat pump?

Should I replace my gas furnace with an electric heat pump?

Learn the reasons why you should consider replacing a gas furnace with an electric heat pump.…

Why is my furnace not igniting?

Why is my furnace not igniting?

Find out why the burner on your furnace isn't igniting.…

Can a furnace be repaired?

Can a furnace be repaired?

Learn about furnace repairs and how much they cost.…

Parts & More

Bottom-Mount Refrigerator
Chainsaw
Electric Range
Gas Range
Gas Walk-Behind Mower
Miter Saw
Parts
Router
Side-By-Side Refrigerator
Table Saw