ICP PHA120N2LA commercial single-package heat pump unit Parts

Here are the diagrams and repair parts for ICP PHA120N2LA commercial single-package heat pump unit, as well as links to manuals and error code tables, if available.

ICP PHA120N2LA commercial single-package heat pump unit
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for PHA120N2LA Commercial Single-Package Heat Pump Unit

  • Comp Zrktfd for ICP PHA120N2LA - Part 1070490

    Functional replacement parts - 7-1/2 thru 10 ton units diagram

    Comp Zrktfd

    Part #1070490

    The manufacturer no longer makes this part, and there's no substitute part

  • Tube Manfold for ICP PHA120N2LA - Part 1072307

    Functional replacement parts - 7-1/2 thru 10 ton units diagram

    Tube Manfold

    Part #1072307

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw for ICP PHA120N2LA - Part 1071172

    Functional replacement diagram

    Screw

    Part #1071172

    The manufacturer no longer makes this part, and there's no substitute part

  • Tube Monifld for ICP PHA120N2LA - Part 1072252

    Functional replacement parts - 7-1/2 thru 10 ton units diagram

    Tube Monifld

    Part #1072252

    The manufacturer no longer makes this part, and there's no substitute part

  • Bracket for ICP PHA120N2LA - Part 1070993

    Functional replacement parts - 7-1/2 thru 10 ton units diagram

    Bracket

    Part #1070993

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel Blower for ICP PHA120N2LA - Part 1070808

    Non-functional replacement parts diagram

    Panel Blower

    Part #1070808

    The manufacturer no longer makes this part, and there's no substitute part

  • Valve Rev for ICP PHA120N2LA - Part 34329002

    Functional replacement parts - 7-1/2 thru 10 ton units diagram

    Valve Rev

    Part #34329002

    The manufacturer no longer makes this part, and there's no substitute part

  • Manual, Technical Information for ICP PHA120N2LA - Part 1072351

    #NI

    All parts diagram

    Manual, Technical Information

    Part #1072351

    The manufacturer no longer makes this part, and there's no substitute part

  • Pnl Evap Top for ICP PHA120N2LA - Part 1072327

    Non-functional replacement parts diagram

    Pnl Evap Top

    Part #1072327

    The manufacturer no longer makes this part, and there's no substitute part

  • Drier for ICP PHA120N2LA - Part 1072235

    Functional replacement parts - 7-1/2 thru 10 ton units diagram

    Drier

    Part #1072235

    The manufacturer no longer makes this part, and there's no substitute part

Most common symptoms to help you fix your dryers

Choose a symptom to see related dryer repairs.

Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…

Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…

Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…

Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…

Main causes: damaged door strike, worn door catch…

Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…

Main causes: bad timer or electronic control board, door switch failure…

Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …

Most common repair guides to help fix your dryers

These step-by-step repair guides will help you safely fix what’s broken on your dryer.

How to replace an electronic control board in an electric dryer

How to replace an electronic control board in an electric dryer

The electronic control board manages the components and controls the cycle times in your electric dryer. Follow these st…

Repair time and Difficulty

 45 minutes or less
How to replace an igniter in a gas dryer

How to replace an igniter in a gas dryer

The igniter in a gas dryer glows white hot during the to light the gas that heats the air in the dryer. If the dryer air…

Repair time and Difficulty

 60 minutes or less
How to replace a dryer thermistor

How to replace a dryer thermistor

The thermistor senses the air temperature in the dryer. If your dryer overheats or doesn't heat at all, the thermistor …

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your dryers

Use the advice and tips in these articles and videos to get the most out of your dryer.

How to use your clothes dryer efficiently

How to use your clothes dryer efficiently

Get expert tips on using your dryer efficiently to save energy.…

Are DIY appliance repairs safe?

Are DIY appliance repairs safe?

Find out how to stay safe when repairing your appliances.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Audio Equipment
Furnace
Gas Line Trimmer
Miter Saw
Parts
Power Drill
Rear-Engine Riding Mower
Washer