Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Carrier 58MVB060F10114 furnace

Carrier 58MVB060F10114 furnace Parts

Here are the diagrams and repair parts for Carrier 58MVB060F10114 furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 58MVB060F10114 Furnace

  • 102,gas Orifice Kit-nat for Carrier 58MVB060F10114 - Part KGAHA0350N44

    Cabinet parts diagram

    102,gas Orifice Kit-nat

    Part #KGAHA0350N44

    The manufacturer no longer makes this part, and there's no substitute part

  • 108,gas Orifice Kit-propa for Carrier 58MVB060F10114 - Part KGAHA5750125

    Cabinet parts diagram

    108,gas Orifice Kit-propa

    Part #KGAHA5750125

    The manufacturer no longer makes this part, and there's no substitute part

  • 068,cabinet Media for Carrier 58MVB060F10114 - Part 325885-401

    Cabinet parts diagram

    068,cabinet Media

    Part #325885-401

    The manufacturer no longer makes this part, and there's no substitute part

  • Icp End Cap for Carrier 58MVB060F10114 - Part 319848-301

    Cabinet parts diagram

    Icp End Cap

    Part #319848-301

    The manufacturer no longer makes this part, and there's no substitute part

  • 087,tube Assy for Carrier 58MVB060F10114 - Part 314781-702

    Cabinet parts diagram

    087,tube Assy

    Part #314781-702

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Blower Fan Wheel for Carrier 58MVB060F10114 - Part LA22RA013

    Cabinet parts diagram

    Furnace Blower Fan Wheel

    Part #LA22RA013

    The manufacturer no longer makes this part, and there's no substitute part

  • Box for Carrier 58MVB060F10114 - Part 310240-301

    Cabinet parts diagram

    Box

    Part #310240-301

    The manufacturer no longer makes this part, and there's no substitute part

  • 141, Weight Motor for Carrier 58MVB060F10114 - Part 321182-301

    Cabinet parts diagram

    141, Weight Motor

    Part #321182-301

    The manufacturer no longer makes this part, and there's no substitute part

  • Bushing for Carrier 58MVB060F10114 - Part HY93NH188

    Cabinet parts diagram

    Bushing

    Part #HY93NH188

    The manufacturer no longer makes this part, and there's no substitute part

  • 057,side Blower for Carrier 58MVB060F10114 - Part 319815-401

    Cabinet parts diagram

    057,side Blower

    Part #319815-401

    The manufacturer no longer makes this part, and there's no substitute part

Carrier Furnace 58MVB060F10114 FAQs

On a gas furnace like the Carrier 58MVB060F10114, the most common failure item is the hot surface igniter because it heats to very high temperatures on every call for heat and becomes brittle over time. A failed igniter typically causes a no-heat condition.

What you’ll usually notice when the igniter is failing

  • Furnace starts, but burners never light
  • You may hear the inducer run, then the system shuts down and retries
  • Short cycling (repeated attempts to ignite)
  • No heat even though the thermostat is calling for heat
  • Intermittent heat that gets worse over time

Quick checks that help confirm the problem

Before any checks, shut off electrical power to the furnace at the disconnect or breaker.

  • Look through the burner area for a cracked or broken igniter element
  • Check wiring connections to the igniter and control for looseness or heat damage
  • If you’re comfortable testing, measure igniter continuity with a meter (an open circuit indicates failure)
  • Use the control’s built-in component test sequence (it can energize the igniter briefly) as outlined in the installation guide

Common “no-heat” parts compared

Part What it does Typical symptom when it fails
Igniter Heats up to light the burners Inducer runs, burners do not light
Pressure switch Proves inducer draft/venting Inducer runs, then shuts down before ignition
Control board Manages ignition sequence and safety logic Erratic operation, no ignition sequence
Roll-out limit switch Shuts down on unsafe burner/heat conditions Burners shut off, furnace locks out

Why it matters

The igniter is part of the furnace’s normal ignition sequence; when it fails, the furnace cannot light the burners, so you get no heat. If you’re troubleshooting repeated ignition attempts, also inspect venting and safety switches because the control can stop ignition when it does not see safe operating conditions.

Last updated: February 2026

A Carrier furnace typically lasts 15 to 30 years. For your Carrier 58MVB060F10114 condensing gas furnace, lifespan is driven most by installation quality (venting, sizing, airflow) and consistent maintenance, since improper setup can cause premature component failure.

Typical lifespan range (what most homeowners see)

Most modern gas furnaces fall into this range when installed correctly and maintained:

Furnace type Typical lifespan What most affects it
Standard efficiency gas furnace 15 to 25 years Heat exchanger condition, airflow, filter changes
High-efficiency condensing gas furnace (like 58MVB series) 15 to 30 years Venting and drainage setup, combustion air quality

What shortens (or extends) furnace life

We see these factors make the biggest difference:

  • Venting and condensate setup: This model requires a special venting system; incorrect vent sizing or materials can create ongoing stress and service issues.
  • Correct sizing and airflow: Duct static pressure and temperature rise need to stay in the intended range to avoid overheating and limit trips.
  • Combustion air quality: Contaminated air (from cleaners, solvents, aerosols, salts) can corrode components and shorten heat exchanger life.
  • Fuel setup: The furnace ships for natural gas; propane conversion requires the correct conversion kit and setup.
  • Routine maintenance: Annual inspection, burner cleaning, and safety checks help prevent small issues from becoming major failures.

Quick checks that help you get the full lifespan

Use these practical habits to protect the heat exchanger, inducer, and controls:

  • Replace or clean the air filter on a regular schedule.
  • Keep supply and return vents open and unobstructed.
  • Keep laundry chemicals, solvents, and aerosols away from the furnace area.
  • Watch for repeated limit switch trips, short cycling, or unusual noises.
  • Follow the venting, combustion air, and setup requirements in the installation guide.

Why it matters

A furnace usually does not fail all at once; it loses life through repeated overheating, poor combustion air, or venting and drainage problems. Getting the installation details right and keeping airflow steady is what most often separates a 15-year furnace from a 25 to 30-year furnace.

Last updated: February 2026

For most furnaces (including the Carrier 58MVB060F10114), the heat exchanger is typically the most expensive major repair because it is labor-intensive and central to safe heating. Other high-cost repairs often involve the control board or draft inducer (vent motor). See the installation guide for safety and service requirements.

Most expensive furnace repairs (typical)

Costs vary by region, access, and whether additional venting or setup adjustments are needed.

  • Heat exchanger: commonly the highest total cost (part plus labor)
  • Draft inducer / vent motor: often expensive, especially on high-efficiency furnaces
  • Control board: can be costly and requires correct diagnosis
  • Blower motor: moderate to high, depending on motor type
  • Gas valve: moderate to high, plus setup and safety checks

How this relates to your Carrier 58MVB060F10114

These model-specific parts on our list are examples of repairs that can land on the higher end:

Repair area Example part for this model Why it can be expensive
Heat exchanger Icp furnace heat exchanger 320723-751 Major disassembly; combustion safety checks required
Venting/inducer Vent motor (part number 320727-755) High-efficiency venting components can be pricey
Controls Control board (part ID HK42FZ035) Misdiagnosis is common; correct wiring and setup matter

Quick ways to avoid paying for the wrong repair

Before replacing a high-dollar part, we use these checks to narrow the failure:

  • Confirm the thermostat is calling for heat and the furnace has power.
  • Check the air filter and return airflow; restricted airflow can trigger limit trips.
  • Inspect venting and condensate drain routing; high-efficiency furnaces are sensitive to vent sizing and drainage.
  • Look for loose, damaged, or overheated wiring connections.
  • Test switches and controls with a meter when safe to do so.

Why it matters

High-efficiency furnaces depend on correct vent sizing, gas input rate, and temperature rise settings; installation or application issues can cause premature component failure and repeated service calls. Following the setup and safety checks in the installation guide helps protect expensive components.

Last updated: February 2026

No. For your Carrier 58MVB060F10114 furnace, we make it straightforward to find and order common replacement parts online by matching the exact model number to the correct parts list and diagrams; this helps you avoid buying look-alike parts that do not fit.

How we recommend finding the right part

Start with the model number 58MVB060F10114, then confirm the part by name and function before ordering.

  • Match the full model number exactly (including all letters and numbers)
  • Use the parts list to identify the correct component category (ignition, safety, venting, controls)
  • Confirm symptoms first (no heat, short cycling, ignition failure, pressure switch issues)
  • Compare the old part to the listing (mounting, connectors, tubing ports)
  • Use the wiring and venting guidance in the installation guide when troubleshooting

Parts that are commonly needed for this model

These are examples of parts we often see replaced on condensing gas furnaces like the Carrier 58MVB060F10114.

What you are fixing Common part type Example from this model’s parts list
Ignition failure or no flame Hot surface igniter Icp furnace burner igniter LH33ZG001
Safety trip with flame rollout symptoms Roll-out limit switch Icp furnace burner roll-out limit switch HH18HA452
Draft or venting problems Vent motor / inducer assembly Vent motor (part number 320727-755)
Pressure switch related shutdowns Pressure switch Switch (part number HH12ZB200)
Control or communication issues Control board / module Control board (part number HK42FZ022)

Why it matters

Furnace parts are not “universal.” On a condensing gas furnace, the venting setup (1-pipe vs 2-pipe), pressure-switch logic, and safety controls all work together; using the correct model-matched part helps the furnace start, run, and shut down safely.

Safety note before you service

The installation instructions emphasize that improper installation or service can lead to serious hazards (fire, electrical shock, carbon monoxide). If you are not fully comfortable diagnosing ignition, venting, or control issues, use a qualified technician and keep the installation guide with the furnace for reference.

Last updated: February 2026

Symptoms for gas walk-behind mowers

Choose a symptom to see related walk-behind mower repairs.

Main causes: engine needs tune up, dirty or clogged carburetor, damaged flywheel key…

Main causes: stale gas, engine needs tune up, bad spark plug, dead battery, bad recoil starter, faulty safety switch, ba…

Main causes: damaged cutting blade, loose cutting blade, damaged flywheel key, engine needs tune up…

Main causes: uneven wheel height settings, damaged wheel, dull or damaged cutting blade…

Main causes: dirty carburetor, bad spark plug, clogged air filter, engine choke problems, clogged gas cap vent…

Main causes: drive control cable failure, worn or broken drive belt, bad transmission, broken drive wheel…

Repair guides for gas walk-behind mowers

These step-by-step repair guides will help you safely fix what’s broken on your walk-behind lawn mower.

How to replace a lawn mower front deck tray

How to replace a lawn mower front deck tray

Learn how to replace the front deck tray on your lawn mower if it's cracked or damaged.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower transmission

How to replace a lawn mower transmission

Learn how to replace the transmission on your lawn mower if it's locked up or won't drive the wheels.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower flywheel key on a flathead engine

How to replace a lawn mower flywheel key on a flathead engine

When you hit a hard object with your mower, the flywheel can shear to protect more expensive components. Learn how to re…

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your furnaces

Use the advice and tips in these articles and videos to get the most out of your walk-behind lawn mower.

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Dishwasher
Dryer
Electric Range
Freestanding Ice Maker
Heating & Cooling
Lawn & Garden Engine
Lcd Television
Refrigerator
Room Air Conditioner
Side-By-Side Refrigerator
Tools & Attachment
Top-Mount Refrigerator
Walk-Behind Mower
Washer