Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Generac GP5500-5939-6 generator

Generac GP5500-5939-6 generator Parts

Here are the diagrams and repair parts for Generac GP5500-5939-6 generator, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for GP5500-5939-6 Generator

  • Oil Seal for Generac GP5500-5939-6 - Part 0G84420116

    Crankcase cover diagram

    Oil Seal

    Part #0G84420111

    Replaced by #0G84420116

    Info Icon
    Manufacturer substitution
    This part replaces 0G84420111. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $39.60
    Minus Item
    Qty
    Plus Item
  • Clamp for Generac GP5500-5939-6 - Part 0G84420259

    Frame assy diagram

    Clamp

    Part #0G84420259

    The manufacturer no longer makes this part, and there's no substitute part

  • Generator Rollover Valve for Generac GP5500-5939-6 - Part 0J7921

    Frame assy diagram

    Generator Rollover Valve

    Part #0J7921

    The manufacturer no longer makes this part, and there's no substitute part

  • Clamp for Generac GP5500-5939-6 - Part 0J00620118

    Frame assy diagram

    Clamp

    Part #0J00620118

    The manufacturer no longer makes this part, and there's no substitute part

  • Crankcase for Generac GP5500-5939-6 - Part 0G8442C110

    Crankcase diagram

    Crankcase

    Part #0G8442C110

    The manufacturer no longer makes this part, and there's no substitute part

  • Bracket for Generac GP5500-5939-6 - Part 0G8542

    Frame assy diagram

    Bracket

    Part #0G8542

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt M6x28 for Generac GP5500-5939-6 - Part OK0100

    Frame assy diagram

    Bolt M6x28

    Part #OK0100

    The manufacturer no longer makes this part, and there's no substitute part

  • Fuel Tank,7 Gal for Generac GP5500-5939-6 - Part 0H7510A0SRV

    Frame assy diagram

    Fuel Tank,7 Gal

    Part #0H7510A0SRV

    The manufacturer no longer makes this part, and there's no substitute part

Generac Generator GP5500-5939-6 FAQs

You can buy replacement parts for your Generac generator through Sears PartsDirect by matching the exact model number (GP5500-5939-6) and selecting the part you need. For part identification, diagrams, and maintenance guidance, use the GP5500-5939-6 owner's manual.

Best ways to get the right part

  • Confirm the full model number on the generator data tag: GP5500-5939-6
  • Use the parts diagram to match the exact component name and location
  • Replace wear items proactively (fuel system parts, ignition parts) to prevent no-start issues
  • For fuel-related problems, start with the simplest items first (fuel shut-off, filter, clamps)
  • If you are unsure between two similar parts, match by part ID and description

Common parts customers replace on this model

Here are a few examples of parts available for Generac GP5500-5939-6:

What it helps with Example part (part ID) What it does
Fuel won’t flow / storage shutoff Generator fuel shut-off valve 0J0974 Opens and closes fuel supply to the carburetor
Fuel starvation / surging Generator fuel filter 0G9914 Traps debris before it reaches the carburetor
Low-oil shutdown symptoms Generator oil level sensor 0G84420105 Signals low oil condition to protect the engine
No output / unstable voltage Generator voltage regulator 0H2579B Helps control alternator output voltage

What to check before ordering

  • Compare the part name and part ID to your diagram callout
  • Inspect for related issues (cracked fuel line, loose clamp, dirty fuel)
  • If the generator sat with fuel in it, plan on fuel-system service (fresh fuel, filter, carburetor cleaning)

Why it matters

Generators often have multiple versions that look similar; ordering by the exact model number and diagram match prevents wrong-part returns and gets you back to reliable power faster.

Last updated: February 2026

On the Generac GP5500-5939-6 portable generator, runtime depends mostly on load and fuel level. A common benchmark for this class is about 10.5 hours at 50% load; higher loads shorten runtime and lighter loads extend it. See the GP5500-5939-6 owner's manual for the exact runtime guidance and operating limits.

What changes the runtime the most

  • Electrical load (watts): more connected load equals faster fuel use
  • Fuel tank fill level: starting with a partial tank reduces total run time
  • Engine speed/governor behavior: unstable RPM can waste fuel and affect output
  • Maintenance condition: dirty fuel system or ignition issues can increase consumption
  • Ambient conditions: very cold or very hot conditions can affect performance

Quick runtime expectations by load

These are practical planning ranges for many 5,500-watt portable generators like the GP5500-5939-6.

Load level What it looks like Typical runtime impact
25% load lights, fridge, small devices longest runtime
50% load mixed essentials baseline (often around 10.5 hours)
75% to 100% load heavy tools, multiple large loads shortest runtime

If your runtime suddenly dropped

Check these common fuel and engine items first:

Why it matters

Knowing expected runtime helps us size fuel on hand, plan refueling intervals, and avoid overloading. Running at a reasonable load also supports steadier voltage regulation and better protection for connected appliances.

Last updated: February 2026

The most common Generac generator problem is a no-start or runs-then-stalls condition caused by fuel issues (stale gas, restricted flow, dirty carburetor) or a safety shutdown from low oil. On the Generac GP5500-5939-6, we start by checking fuel delivery and oil level per the GP5500-5939-6 owner's manual.

Most common causes (and what to check first)

  • Stale fuel or varnish in the carburetor: drain old gas and refill with fresh fuel.
  • Restricted fuel flow: confirm the tank vent is open and the shut-off valve is on.
  • Clogged fuel filter: replace the generator fuel filter 0G9914 if fuel looks dirty or flow is weak.
  • Low-oil shutdown: verify oil level; if it still shuts down, test/replace the generator oil level sensor 0G84420105.
  • Ignition problems: if it cranks but never fires, inspect the plug and consider testing the generator engine ignition coil 0G84420150.
  • Unstable RPM or surging: a misadjusted or sticking governor can cause hunting; inspect linkage and consider the governor 0G84420221.

Quick symptom-to-cause guide

Symptom Most likely cause Best first action
Won’t start at all Stale fuel, low oil shutdown, ignition Fresh fuel, confirm oil level, check spark plug
Starts then dies Fuel restriction, clogged filter, low-oil sensor Check valve/vent, replace filter, verify oil level
Surges at no load Dirty carburetor, governor issue Clean carburetor, inspect governor linkage
Runs but no/low output Voltage regulation or alternator issue Check connections; test regulator/output

Why it matters

Fuel and oil-related issues are the most common because portable generators often sit unused. Old fuel clogs small passages, and low-oil protection can shut the engine down quickly to prevent damage.

Tips that prevent repeat problems

  • Run the generator periodically so fuel does not sit in the carburetor.
  • Use fresh gasoline and keep the tank clean.
  • Replace the fuel filter on schedule or anytime contamination is suspected.
  • Keep oil at the correct level before every run.

Last updated: February 2026

The Generac GP5500-5939-6 uses a Generac 4-stroke OHV (overhead valve) gasoline engine. For the exact engine displacement (cc), engine family, and spec details tied to your unit’s serial number, we recommend confirming in the GP5500-5939-6 owner’s manual.

How to identify the exact engine on your unit

Even within the same model, engine spec variants can exist. Use these checks to match the correct parts and tune-up specs:

  • Locate the engine data label (often on the valve cover, recoil starter housing, or blower housing)
  • Record the engine model/type and spec code (if listed)
  • Match the spec code to the parts breakdown before ordering
  • Compare carburetor and ignition components if the label is missing
  • Use the generator model number GP5500-5939-6 plus the engine spec to avoid mismatches

Common engine features you’ll see on this model

Most portable Generac OHV engines used on units like the GP5500-5939-6 include these systems:

  • Recoil start system
  • Mechanical governor to control engine speed under load
  • Low-oil protection (oil level sensor or shutdown circuit)
  • Fuel shut-off and inline fuel filtration

If you’re troubleshooting surging, stalling, or no-start, the fuel and ignition systems are the first places we check.

Parts that relate directly to engine identification and performance

These parts are commonly referenced when diagnosing engine-related issues on the GP5500-5939-6:

Symptom What to check Example part for this model
Starts then dies Fuel flow restriction Generac generator fuel shut-off valve 0J0974
Runs rough or starves for fuel Dirty fuel supply Generator fuel filter 0G9914
Shuts down unexpectedly Low-oil circuit Generator oil level sensor 0G84420105
Hunts or surges under load Speed control Governor 0G84420221

Why it matters

The exact engine spec determines the correct spark plug type, valve clearance targets, governor settings, and carburetor configuration. Matching the engine label and the manual prevents ordering the wrong Generac parts and helps restore stable output.

Last updated: February 2026

Symptoms for electric ranges

Main causes: faulty surface element, burner control switch failure, temperature limiter not working properly, loose wiri…

Main causes: impact from dropping an item on the glass surface, ceramic glass surface flaw, surface element temperature …

Repair guides for electric ranges

How to replace an oven temperature sensor on an electric range

How to replace an oven temperature sensor on an electric range

These step-by-step instructions guide you through replacing an oven temperature sensing probe.…

Repair time and Difficulty

 15 minutes or less
How to replace an electric range oven control board

How to replace an electric range oven control board

If the electronic oven control board isn't powering the bake and broil functions, you can replace it in less than half a…

Repair time and Difficulty

 15 minutes or less
How to replace a range surface element control switch

How to replace a range surface element control switch

The surface element control switch lets you turn the stovetop elements on and off, and to set the heat level. These step…

Repair time and Difficulty

 15 minutes or less

Articles and videos for electric ranges

How to disassemble an Electrolux EW30 freestanding electric range

How to disassemble an Electrolux EW30 freestanding electric range

See how to access control boards and oven components in an Electrolux electric range.…

Radiant surface element on range not working video

Radiant surface element on range not working video

Troubleshoot the likely causes why a stovetop burner won’t heat.…

Hidden bake element has long preheat

Hidden bake element has long preheat

Here's why ovens with hidden bake elements take longer to preheat.…

Parts & More

Bottom-Mount Refrigerator
Dryer
Electric Range
Elliptical Machine
Front-Engine Lawn Tractor
Gas Chainsaw
Gas Snowblower
Generator
Lawn Edger
Parts
Refrigerator
Tiller
Top-Mount Refrigerator
Warming Drawer
Washer