Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
ICP NXA642GKA100 split-system air conditioner

ICP NXA642GKA100 split-system air conditioner Parts

Here are the diagrams and repair parts for ICP NXA642GKA100 split-system air conditioner, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for NXA642GKA100 Split-System Air Conditioner

  • Lug Ground for ICP NXA642GKA100 - Part 1172300

    Control box diagram

    Lug Ground

    In Stock
    $24.35
    Minus Item
    Qty
    Plus Item
  • Top Cover for ICP NXA642GKA100 - Part 1178565

    Outer asy diagram

    Top Cover

    In Stock
    $372.29
    Minus Item
    Qty
    Plus Item
  • Central Air Conditioner Filter Dryer for ICP NXA642GKA100 - Part 1172009

    Inner asy diagram

    Filter Drier

    Part #1173955

    Replaced by #1172009

    Info Icon
    Manufacturer substitution
    This part replaces 1173955. Substitute parts can look different from the original.
    In Stock
    $181.64
    Minus Item
    Qty
    Plus Item
  • Valve Liq. for ICP NXA642GKA100 - Part 1185864

    Inner asy diagram

    Service Valve

    Part #1172792

    Replaced by #1185864

    Info Icon
    Manufacturer substitution
    This part replaces 1172792. Substitute parts can look different from the original.
    In Stock
    $98.01
    Minus Item
    Qty
    Plus Item
  • Valve for ICP NXA642GKA100 - Part 1185863

    Inner asy diagram

    Service Valve

    Part #1172727

    Replaced by #1185863

    Info Icon
    Manufacturer substitution
    This part replaces 1172727. Substitute parts can look different from the original.
    In Stock
    $162.60
    Minus Item
    Qty
    Plus Item
  • Filter Drier Kit for ICP NXA642GKA100 - Part 1174727

    Inner asy diagram

    Filter Drier Kit

    Part #1174727

    The manufacturer no longer makes this part, and there's no substitute part

  • Condenser Coil for ICP NXA642GKA100 - Part 1183625

    Inner asy diagram

    Condenser Coil

    Part #1183625

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt for ICP NXA642GKA100 - Part 1173630

    Inner asy diagram

    Bolt

    Part #1173630

    The manufacturer no longer makes this part, and there's no substitute part

  • Grille Inl for ICP NXA642GKA100 - Part 1178791

    Outer asy diagram

    Grille Inl

    Part #1178791

    The manufacturer no longer makes this part, and there's no substitute part

  • Box Cover for ICP NXA642GKA100 - Part 1178920

    Outer asy diagram

    Box Cover

    Part #1178920

    The manufacturer no longer makes this part, and there's no substitute part

ICP Split-System Air Conditioner NXA642GKA100 FAQs

For your Icp split-system air conditioner model NXA642GKA100, the reliable way to tell whether it uses R-410A or R-22 is to read the refrigerant type printed on the outdoor unit’s data plate (nameplate) and confirm it against the refrigerant information in the NXA642GKA100 owner's manual.

Fast ways to identify the refrigerant
  • Check the outdoor unit nameplate: look for “R-410A” or “R-22” (sometimes shown as HCFC-22).
  • Look for service labels inside the electrical/control panel area (some units list refrigerant and factory charge there).
  • Match model and serial information: keep the outdoor unit model and serial handy when comparing to documentation.
  • Do not rely on cap color or hose fittings alone: service setups vary by technician and do not prove refrigerant type.
  • Use the manual as your cross-check: it helps confirm what the unit was designed to use.
What changes between R-410A and R-22 (why you should care)

Using the correct refrigerant matters because the system pressures, service procedures, and some components differ.

Item R-22 systems R-410A systems
Operating pressure Lower Higher
Retrofit/“top-off” approach Sometimes attempted (not recommended) Must use correct refrigerant only
Service risk if misidentified Compressor damage, poor cooling Compressor damage, safety risk
If the nameplate is missing or unreadable

Use these practical checks before any service work:

  • Compare the outdoor unit model number to the equipment documentation in the NXA642GKA100 owner's manual.
  • Inspect for a refrigerant label on the cabinet or inside the service panel.
  • Have a qualified HVAC technician confirm refrigerant type before connecting gauges or adding refrigerant.
Why it matters

Refrigerant identification is not just a label detail; it directly affects safe service pressures and whether the system can be charged and repaired correctly. Confirming the refrigerant first helps prevent misdiagnosis and protects the compressor.

Last updated: February 2026

Replacing (recharging) R-410A in an AC system typically costs about $50 to $80 per pound for refrigerant, plus labor, diagnostics, and any leak repair. For an Icp split-system air conditioner like NXA642GKA100, the total price varies most based on whether the system is low due to a leak.

What usually makes the price go up or down
  • Leak present vs. no leak: If refrigerant is low, a leak check and repair is normally part of the job.
  • How much refrigerant is needed: A small top-off costs less than a near-empty system.
  • Access and time on site: Long line sets, tight service access, or multiple visits add labor.
  • Electrical issues that mimic low charge: A failed contactor or fan can look like a cooling problem.
  • Coil condition and airflow: Dirty outdoor coils or a clogged filter can reduce cooling even with correct charge.
Before paying for refrigerant, check these basics

Our NXA642GKA100 manual recommends a few quick checks that often solve “not cooling” complaints without refrigerant work:

  • Confirm the thermostat is set to COOL and below room temperature
  • Inspect and replace or clean the return air filter (dirty filters are a common cause of poor cooling)
  • Check breakers/fuses
  • Clear debris from the outdoor unit coils and fins and make sure nothing blocks the fan

For the full maintenance and “what to do if your system does not work” steps, use the owner's manual.

Common service scenarios and what you’re paying for
Scenario What the technician typically does Cost driver
System not cooling, charge unknown Diagnostics, airflow checks, electrical checks Labor time
Low refrigerant suspected Leak search, repair plan, then recharge Leak location/repair
Outdoor unit not running Tests contactor, capacitor, fan motor circuit Parts + labor

If the outdoor unit will not start, a failed central air conditioner contactor 1172472 is one common electrical cause.

Why it matters

R-410A does not get “used up.” If your NXA642GKA100 needs refrigerant, fixing the underlying cause (often a leak or airflow problem) protects the compressor and helps restore efficiency.

Last updated: February 2026

Most central air conditioning units last 15 to 20 years. For your Icp split-system air conditioner model NXA642GKA100, regular maintenance (especially keeping airflow and outdoor coils clean) helps the compressor and fan system reach that typical lifespan; see the maintenance schedule in the owner's manual.

Typical lifespan ranges (what to expect)

Lifespan depends most on maintenance, installation quality, and run time.

Unit type Typical lifespan What shortens life fastest
Central split-system air conditioner (like NXA642GKA100) 15 to 20 years Dirty filters, clogged outdoor coils, electrical issues
Older or poorly maintained central AC 10 to 12 years Restricted airflow, overheating, repeated hard starts
Maintenance that most directly protects lifespan

The manual calls out several homeowner checks that prevent efficiency loss and compressor damage.

  • Inspect the return air filter monthly; replace or clean it as needed.
  • Keep the outdoor coil and fins clear of grass clippings, leaves, lint, and dirt.
  • Make sure the outdoor fan blade area is unobstructed (no branches or debris).
  • Check breakers and fuses if the system will not run.
  • Turn OFF power to indoor and outdoor units before any maintenance.
Why it matters

A central AC usually fails early from heat and strain caused by restricted airflow or dirty outdoor coils. Keeping filters and coils clean helps the system cool properly, reduces compressor stress, and supports a full 15 to 20 year service life.

Last updated: February 2026

On most central AC systems (including the Icp NXA642GKA100), the most common electrical failure is the run capacitor, but the most commonly replaced control part is often the contactor. Dirty filters and blocked outdoor coils also cause frequent “no cool” complaints and can lead to compressor damage; follow the maintenance steps in the owner's manual.

What typically fails most often (and what you’ll notice)
  • Run capacitor: outdoor unit hums, fan will not start, intermittent starting
  • Contactor: outdoor unit will not run even when thermostat calls for cooling
  • Condenser fan issues: poor airflow, overheating, unit shuts off on safety
  • Airflow restrictions (dirty filter, blocked coil): weak cooling, icing, high energy use
  • Electrical supply problems (breaker/fuse): unit dead, no outdoor operation
Model-specific parts to check first on NXA642GKA100

If your outdoor unit is not starting or is short-cycling, these parts on this model are common starting points:

Symptom What to check Example part for this model
Outdoor unit will not pull in Control switching Central air conditioner contactor 1172472
Fan blade not moving, poor airflow Fan assembly Fan 1173661
Rattling or damaged top protection Guarding and safety Fan guard 1178604
Quick checks we recommend before replacing parts

Turn OFF power to both the indoor and outdoor units before opening panels.

  • Confirm thermostat is set to COOL and setpoint is below room temperature
  • Check the return air filter; replace or clean it (dirty filters are a leading cause of poor cooling and compressor problems)
  • Reset any tripped breakers or replace blown fuses
  • Clear debris from the outdoor coil and fan area (leaves, grass clippings, lint)
  • Look for obvious burnt wiring or loose connections (repair only if qualified)
Why it matters

A failed capacitor or contactor can stop cooling immediately, but airflow and coil maintenance often prevents repeat failures. The manual’s maintenance steps (filter, drain, outdoor coil cleaning) help protect the compressor, which is the most expensive component.

Last updated: February 2026

Symptoms for gas walk-behind mowers

Choose a symptom to see related walk-behind mower repairs.

Main causes: engine needs tune up, dirty or clogged carburetor, damaged flywheel key…

Main causes: stale gas, engine needs tune up, bad spark plug, dead battery, bad recoil starter, faulty safety switch, ba…

Main causes: damaged cutting blade, loose cutting blade, damaged flywheel key, engine needs tune up…

Main causes: uneven wheel height settings, damaged wheel, dull or damaged cutting blade…

Main causes: dirty carburetor, bad spark plug, clogged air filter, engine choke problems, clogged gas cap vent…

Main causes: drive control cable failure, worn or broken drive belt, bad transmission, broken drive wheel…

Repair guides for gas walk-behind mowers

These step-by-step repair guides will help you safely fix what’s broken on your walk-behind lawn mower.

How to replace a lawn mower front deck tray

How to replace a lawn mower front deck tray

Learn how to replace the front deck tray on your lawn mower if it's cracked or damaged.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower transmission

How to replace a lawn mower transmission

Learn how to replace the transmission on your lawn mower if it's locked up or won't drive the wheels.…

Repair time and Difficulty

 60 minutes or less
How to replace a lawn mower flywheel key on a flathead engine

How to replace a lawn mower flywheel key on a flathead engine

When you hit a hard object with your mower, the flywheel can shear to protect more expensive components. Learn how to re…

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your central air conditioners

Use the advice and tips in these articles and videos to get the most out of your walk-behind lawn mower.

Easy DIY appliance repairs that anyone can do

Easy DIY appliance repairs that anyone can do

Get advice on simple DIY fixes for appliances that you can safely do on your own.…

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Range
Freestanding Ice Maker
Front-Engine Lawn Tractor
Gas Leaf Blower
Gas Range
Gas Walk-Behind Mower
Parts
Range
Side-By-Side Refrigerator
Speaker
Top-Mount Refrigerator
Water & Ice System
Welder