Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
York D2CG076N08246A cooling unit

York D2CG076N08246A cooling unit Parts

Here are the diagrams and repair parts for York D2CG076N08246A cooling unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for D2CG076N08246A Cooling Unit

  • Blade for York D2CG076N08246A - Part 02631361000

    Functional replacement parts diagram

    Fan Blade

    Part #026-25511-000

    Replaced by #02631361000

    Info Icon
    Manufacturer substitution
    This part replaces 026-25511-000. Substitute parts can look different from the original.
    In Stock
    $135.20
    Minus Item
    Qty
    Plus Item
  • Motor Run Capacitor for York D2CG076N08246A - Part 12907

    Functional replacement parts diagram

    Cap Run

    Part #024-20045-000

    Replaced by #12907

    Info Icon
    Manufacturer substitution
    This part replaces 024-20045-000. Substitute parts can look different from the original.
    This item is not returnable
    In Stock
    $4.76
    17% OFF Phone Price : $5.76Info Icon
    Minus Item
    Qty
    Plus Item
  • Side Panel for York D2CG076N08246A - Part 363-93683-000

    Condensing unit diagram

    Side Panel

    Part #363-93683-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Rubber Boot for York D2CG076N08246A - Part 028-04133-000

    Functional replacement parts diagram

    Rubber Boot

    Part #028-04133-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel, Top (evaporator) for York D2CG076N08246A - Part 363-89647-002

    Condensing unit diagram

    Panel, Top (evaporator)

    Part #363-89647-002

    The manufacturer no longer makes this part, and there's no substitute part

  • Igniter for York D2CG076N08246A - Part 025-26361-000

    Functional replacement parts diagram

    Igniter

    Part #025-26361-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Air Filter for York D2CG076N08246A - Part 026-10018-000

    Condensing unit diagram

    Air Filter

    Part #026-10018-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Plug for York D2CG076N08246A - Part 025-19670-900

    Condensing unit diagram

    Plug

    Part #025-19670-900

    The manufacturer no longer makes this part, and there's no substitute part

  • Post Rear for York D2CG076N08246A - Part 063-87618-000

    Condensing unit diagram

    Post Rear

    Part #063-87618-000

    The manufacturer no longer makes this part, and there's no substitute part

  • Box Flue for York D2CG076N08246A - Part 063-93515-000

    Condensing unit diagram

    Box Flue

    Part #063-93515-000

    The manufacturer no longer makes this part, and there's no substitute part

Most common symptoms to help you fix your heating & cooling combined units

Choose a symptom to see related heating and air conditioning system repairs.

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Thermostat problem, clogged air filter, burner failure…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: Errant thermostat settings, lack of power, bad interlock switches, lack of exhaust ventilation, wiring fail…

Dirty flame sensor, failed flame sensor, damaged burner, bad high limit switch…

Most common repair guides to help fix your heating & cooling combined units

These step-by-step repair guides will help you safely fix what’s broken on your HVAC system.

How to unclog the air conditioner drain line

How to unclog the air conditioner drain line

The condensate drain line for your central air conditioner can clog with mold and mildew. Water will back up and start d…

Repair time and Difficulty

 15 minutes or less
How to replace the furnace flame sensor

How to replace the furnace flame sensor

The flame sensor detects when furnace burner flames are lit. You may need to replace the flame sensor if flames only sta…

Repair time and Difficulty

 15 minutes or less
How to replace a heating and air conditioning system thermostat

How to replace a heating and air conditioning system thermostat

The control thermostat for your HVAC system can stop working. This repair guide shows how to replace it.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your heating & cooling combined units

Use the advice and tips in these articles and videos to get the most out of your HVAC system.

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Why is my furnace not igniting?

Why is my furnace not igniting?

Find out why the burner on your furnace isn't igniting.…

Can a furnace be repaired?

Can a furnace be repaired?

Learn about furnace repairs and how much they cost.…

Parts & More

Boating
Central Air Conditioner
Gas Line Trimmer
Gas Walk-Behind Mower
Gas Water Heater
Parts
Room Air Conditioner
Walk-Behind Mower
Washer
Wine & Beverage Cooler