Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

Carrier FK4DNF003000 fan coil Parts

Here are the diagrams and repair parts for Carrier FK4DNF003000 fan coil, as well as links to manuals and error code tables, if available.

Carrier FK4DNF003000 fan coil
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for FK4DNF003000 Fan Coil

  • Bracket for Carrier FK4DNF003000 - Part 314900-203

    Blower assy diagram

    Bracket

    In Stock
    $16.77
    Minus Item
    Qty
    Plus Item
  • Nameplate for Carrier FK4DNF003000 - Part 312250-407

    Casing assy diagram

    Nameplate

    In Stock
    $30.46
    Minus Item
    Qty
    Plus Item
  • Payne Distr Liqd for Carrier FK4DNF003000 - Part 319072-408

    Coil assy diagram

  • Motor Blow for Carrier FK4DNF003000 - Part HD44AR135

    Casing assy diagram

    Motor

    Part #HD44AE132

    Replaced by #HD44AR135

    Info Icon
    Manufacturer substitution
    This part replaces HD44AE132. Substitute parts can look different from the original.
    In Stock
    $1033.80
    Minus Item
    Qty
    Plus Item
  • Central Air Conditioner Electronic Control Board for Carrier FK4DNF003000 - Part HK61EA005

    Board Circ

    Part #CESO130035-00

    Replaced by #HK61EA005

    Info Icon
    Manufacturer substitution
    This part replaces CESO130035-00. Substitute parts can look different from the original.
    In Stock
    $410.70
    $12.00 OFF Phone Price : $422.70Info Icon
    Minus Item
    Qty
    Plus Item
  • Door Assembly for Carrier FK4DNF003000 - Part 328090-703

    Casing assy diagram

    Door Assembly

    Part #328090-703

    The manufacturer no longer makes this part, and there's no substitute part

  • Heater Assembly for Carrier FK4DNF003000 - Part 324638-701

    Casing assy diagram

    Heater Assembly

    Part #324638-701

    The manufacturer no longer makes this part, and there's no substitute part

  • Shield for Carrier FK4DNF003000 - Part 314925-302

    Coil assy diagram

    Shield

    Part #314925-302

    The manufacturer no longer makes this part, and there's no substitute part

  • Heater Assembly for Carrier FK4DNF003000 - Part 324639-701

    Casing assy diagram

    Heater Assembly

    Part #324639-701

    The manufacturer no longer makes this part, and there's no substitute part

  • Plate for Carrier FK4DNF003000 - Part 314895-403

    Casing assy diagram

    Plate

    Part #314895-403

    The manufacturer no longer makes this part, and there's no substitute part

Carrier Fan Coil FK4DNF003000 FAQs

Yes. For your Carrier FK4DNF003000 (fan coil), “fan coil” and “air handler” are commonly used to describe the same indoor unit: a blower (fan) that moves air across a heating and/or cooling coil to condition the air.

How the terms are used in HVAC

In most residential split systems, people use these terms interchangeably. In practice, the name usually depends on what the indoor unit is paired with and what features it includes.

  • Air handler: general term for the indoor blower cabinet that moves and conditions air.
  • Fan coil: often used when the unit’s main job is moving air across a coil (cooling coil, heating coil, or both).
  • Many units also include controls, safety switches, and sometimes an electric heat kit.
Quick comparison
Term you hear What it usually means What you should check before ordering parts
Air handler Indoor blower unit for a split system Model number and control board style
Fan coil Indoor unit focused on air moving across a coil Coil type, blower motor, and wiring connections
Why it matters for parts and troubleshooting

Using the right term helps you land on the correct parts list and wiring layout for your exact model. For example, if you are diagnosing no-blower, no-cooling, or intermittent operation, the control board is often part of the troubleshooting path.

Common “air handler or fan coil” symptoms that point to controls or wiring
  • Blower will not start, but thermostat is calling
  • Blower runs continuously when it should cycle
  • Outdoor unit runs but weak airflow indoors
  • Intermittent operation after power resets
  • Burnt smell or visible heat damage near low-voltage wiring

If you are testing electrical components, use a meter and follow safe power-off practices; our how to use a multimeter to test electrical parts video is a good starting point.

Parts you can shop for this model

If you determine a control issue, the model-specific control board listed for FK4DNF003000 is board circ HK61EA005.

Last updated: February 2026

For a 3-ton air handler (like the Carrier FK4DNF003000 fan coil), you typically need about 1,200 CFM of airflow. That is based on the common HVAC target of ~400 CFM per ton to move enough air across the evaporator coil for proper cooling and dehumidification.

Quick rule of thumb (and when to adjust it)

Most residential systems are set up around 350 to 450 CFM per ton depending on comfort goals and conditions.

  • Standard cooling: ~400 CFM per ton (3 tons = ~1,200 CFM)
  • Better dehumidification (humid climates): ~350 CFM per ton (3 tons = ~1,050 CFM)
  • Higher sensible cooling (drier climates): ~450 CFM per ton (3 tons = ~1,350 CFM)
What happens if CFM is too low or too high?

Airflow that is far off target can cause comfort problems and equipment stress.

  • Too low: coil can get too cold, reduced cooling, possible icing, noisy return air
  • Too high: reduced dehumidification, drafty vents, higher blower noise
  • Either way: uneven temperatures and longer run times
Target airflow table for a 3-ton setup
Airflow target CFM per ton Approx. total CFM (3 tons)
Dehumidify more 350 1,050
Typical target 400 1,200
Maximize airflow 450 1,350
How we recommend checking airflow on a fan coil

Because FK4DNF003000 configurations vary (duct static pressure, filter type, coil, blower settings), we recommend verifying airflow instead of guessing.

  • Confirm the blower speed tap/setting is correct
  • Check the air filter and return grille for restriction
  • Inspect the evaporator coil for dirt buildup
  • Measure external static pressure and compare to the blower performance data
  • If you are troubleshooting electrical control issues, inspect the control board connections (a failed board can prevent the blower from reaching the correct speed); see board circ HK61EA005
Why it matters

Correct CFM protects the evaporator coil, improves comfort, and helps your Carrier air handler deliver the capacity your 3-ton system is designed for.

Last updated: February 2026

A 3-ton Carrier air handler is typically about 40 to 55 inches tall, but the exact height depends on the cabinet style (upflow, horizontal, or multi-position) and the specific series. For your Carrier FK4DNF003000 fan coil, use the model-specific parts and cabinet configuration to confirm fit before ordering.

Typical height ranges (what you can plan around)

Most 3-ton fan coil and air handler cabinets fall into these common ranges:

  • Standard vertical cabinet: ~40 to 55 inches tall
  • Compact/low-profile cabinet: ~34 to 45 inches tall
  • Horizontal applications: height is often less critical than overall clearance and service access
Configuration Typical height What changes it most
Upflow / downflow 40 to 55 in. Coil size, blower section, filter rack
Horizontal 34 to 45 in. Drain pan style, hanger kit, duct transitions
Closet / tight install 34 to 45 in. Return-air setup, platform, secondary drain pan
How to confirm the height for FK4DNF003000

Use these practical checks to lock in the correct measurement for your install:

  • Measure the cabinet height only (exclude the supply plenum and any field-fabricated transitions).
  • Confirm whether you have a factory filter rack or an add-on return box that adds height.
  • Check for a secondary drain pan or float switch that may require extra clearance.
  • Verify the orientation (vertical vs. horizontal) because the “height” dimension changes with mounting.
  • Match your unit’s electrical/control setup; a replacement control can affect service access needs.

If you are troubleshooting fitment while replacing controls, the board circ HK61EA005 is a common component that can drive service-clearance needs around the blower/control area.

Why it matters

Air handler height affects more than “will it fit.” It also impacts condensate drainage slope, duct alignment, filter access, and whether a technician can safely service the blower and control board without removing the cabinet.

Last updated: February 2026

A “4 ton” air handler refers to cooling capacity (about 48,000 BTU/hr), not a single standard cabinet size. For Carrier fan coil systems like model FK4DNF003000, physical dimensions vary by series, orientation (upflow, downflow, horizontal), and installed options such as an electric heat kit.

Typical size range for a 4 ton air handler

Most 4 ton air handlers fall into these common ranges:

  • Width: about 17 to 24 inches
  • Depth: about 20 to 26 inches
  • Height: about 45 to 60 inches
  • Weight: often 90 to 160 lb (varies with coil and heater)
What changes the size the most

These factors usually drive the biggest dimension differences:

  • Orientation and drain pan setup (vertical vs. horizontal)
  • Coil design (A-coil vs. slab coil, cabinet style)
  • Electric heat kit installed (adds depth and wiring space)
  • Filter rack or return plenum configuration
  • Cabinet insulation and sound features
Quick planning checklist (so it fits the closet or attic)

Before ordering parts or planning a replacement, we recommend:

  • Measure the existing cabinet width, depth, and height at the widest points
  • Confirm service clearance (front panel removal and blower access)
  • Note duct connection sizes (supply plenum and return opening)
  • Check drain line location and secondary pan space
  • Verify the model number on the data tag using how to find your appliance model number (and what it means for parts)
Capacity vs. size at a glance
What you’re looking at What it tells you What it does not tell you
“4 ton” rating Approx. 48,000 BTU/hr airflow/capacity class Exact cabinet dimensions
Model number (FK4DNF003000) The specific Carrier fan coil configuration The size of other 4 ton models
Why it matters

Air handler size affects whether the unit physically fits, whether the duct transitions line up, and whether you can remove panels for service. Getting the model number right also helps ensure you order the correct control parts, such as the board circ HK61EA005.

Last updated: February 2026

FK4DNF003000 is the model number for a Carrier fan coil (air handler). We use this exact model number to match the correct replacement parts and electrical components for your specific unit so the fit, wiring connections, and ratings line up.

What the model number tells you

For Carrier air handlers, the model number identifies the exact indoor unit configuration. That matters because parts can vary by cabinet size and control setup.

Use FK4DNF003000 when you need to:

  • Pull the correct parts list and diagrams for your air handler
  • Confirm a control board matches your wiring connectors
  • Verify mounting hardware and brackets match the cabinet
  • Order the right replacement part the first time
Example parts listed for this model

These are examples of parts associated with FK4DNF003000 on our parts list:

Quick comparison
Part What it does Common replacement reason
Board Circ (control board) Controls blower operation and low-voltage functions No blower, intermittent operation, visible board damage
Bracket Secures internal components Vibration noise, loose components, bent or broken mount
Why it matters

Using the exact model number FK4DNF003000 prevents ordering a similar-looking part that does not match the mounting points, connectors, or control logic of your Carrier air handler.

Last updated: February 2026

Repair guides for side-by-side refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a press-in door gasket in a side-by-side refrigerator

How to replace a press-in door gasket in a side-by-side refrigerator

The door gasket seals the gap around the door to keep the cold air in and the warm air out. Replace a worn or damaged do…

Repair time and Difficulty

 15 minutes or less
How to replace an ice maker in a side-by-side refrigerator

How to replace an ice maker in a side-by-side refrigerator

Learn how to replace the ice maker in a side-by-side refrigerator with these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your air handlers

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Introducing new technical repair content that we’re developing for the Sears Technical Institute

Learn about Sears Technical Institute and the advanced technical content being developed for aspiring appliance techs.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Range
Electric Wall Oven
Front-Engine Lawn Tractor
Gas Line Trimmer
Gas Range
Gas Walk-Behind Mower
Lathe
Parts
Side-By-Side Refrigerator