Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Craftsman CMXGGAS030729 generator

Craftsman CMXGGAS030729 generator Parts

Here are the diagrams and repair parts for Craftsman CMXGGAS030729 generator, as well as links to manuals and error code tables, if available.

By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for CMXGGAS030729 Generator

  • Shaft-sleeve (2) for Craftsman CMXGGAS030729 - Part 84001083

    Wheel kit diagram

    Shaft-sleeve (2)

    Part #84001083

    The manufacturer no longer makes this part, and there's no substitute part

  • Refer To: Alternator Group for Craftsman CMXGGAS030729 - Part 80076321

    Main unit diagram

    Refer To: Alternator Group

    Part #80076321

    The manufacturer no longer makes this part, and there's no substitute part

  • Washer (2) for Craftsman CMXGGAS030729 - Part 48911GS

    Main unit diagram

    Washer (2)

    Part #48911GS

    The manufacturer no longer makes this part, and there's no substitute part

  • Decal for Craftsman CMXGGAS030729 - Part 84001093

    Main unit diagram

    Decal

    Part #84001093

    The manufacturer no longer makes this part, and there's no substitute part

  • Decal for Craftsman CMXGGAS030729 - Part 84001111

    Main unit diagram

    Decal

    Part #84001111

    The manufacturer no longer makes this part, and there's no substitute part

  • Mount-vibration (4) for Craftsman CMXGGAS030729 - Part 84001086

    Main unit diagram

    Mount-vibration (4)

    Part #84001086

    The manufacturer no longer makes this part, and there's no substitute part

  • Boot, Rubber for Craftsman CMXGGAS030729 - Part 207897GS

    Alternator diagram

    Boot, Rubber

    Part #207897GS

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt (4) for Craftsman CMXGGAS030729 - Part 84001687

    Alternator diagram

    Bolt (4)

    Part #84001687

    The manufacturer no longer makes this part, and there's no substitute part

  • Harness-wiring for Craftsman CMXGGAS030729 - Part 84001062

    Control panel diagram

    Harness-wiring

    Part #84001062

    The manufacturer no longer makes this part, and there's no substitute part

  • Nut (2) for Craftsman CMXGGAS030729 - Part 84001059

    Wheel kit diagram

    Nut (2)

    Part #84001059

    The manufacturer no longer makes this part, and there's no substitute part

Craftsman Generator CMXGGAS030729 FAQs

The Craftsman CMXGGAS030729 generator typically takes about 20 oz (0.6 L) of engine oil for a full fill from empty. For the correct final level, we always fill slowly and stop when the oil reaches the “FULL” mark on the dipstick as shown in the CMXGGAS030729 owner's manual.

How to check and fill oil correctly

  • Place the generator on a level surface and let the engine cool.
  • Remove the oil fill cap/dipstick, wipe it clean, then reinsert to check level.
  • Add the recommended oil a little at a time; recheck the dipstick often.
  • Do not overfill; too much oil can cause hard starting, smoking, or fouled spark plug.
  • Reinstall the dipstick securely before starting.

Oil type and capacity quick guide

What you need Typical spec for this generator type What to do on your CMXGGAS030729
Oil capacity (dry) About 20 oz (0.6 L) Fill to dipstick “FULL” line
Common oil type SAE 10W-30 Use the oil grade listed in the manual
When to check Before each use Check level with unit level

Why it matters

Running low on oil can trigger low-oil shutdown (if equipped) or cause rapid engine wear. Overfilling can also create performance problems. The dipstick level is the final authority because a small tilt or leftover oil changes the amount needed.

Last updated: February 2026

Craftsman generators, including the Craftsman CMXGGAS030729, are a solid choice when you want dependable backup power at a reasonable price. In real-world use, they are typically praised for straightforward operation and good value; compared with premium brands, the most common tradeoffs are higher noise and more basic fit and finish.

What “good” means for a portable generator

A generator is “good” when it starts reliably, holds steady voltage under load, and has parts support for normal wear items (fuel system, breakers, switches, and controls). For the CMXGGAS030729, we commonly see owners focus on these practical factors:

  • Starts consistently (fresh fuel, good spark, clean air flow)
  • Produces stable power for mixed household loads
  • Has working overload protection (breakers)
  • Has serviceable fuel and ignition components
  • Has a support path for replacement parts and maintenance

Quick pros and tradeoffs (typical for this class)

What you get What to watch for Best practice
Strong value for home backup Louder than many inverter-only premium units Place it outdoors at a safe distance; use a heavy-duty cord sized for the load
Simple controls and common service parts Fuel-related issues after storage Drain or treat fuel before storage; run it periodically
Easy to maintain with basic tools Wear on small hardware and accessories Inspect fasteners, wheels, and guards during oil changes

Parts that matter most for long-term reliability

If performance drops, these are the first areas we check because they directly affect starting and power delivery:

Why it matters

A “good” generator is the one that matches your use case. For occasional outages, a Craftsman portable generator is a practical balance of cost and capability. If you need ultra-quiet operation or frequent, long runtime use, that is where higher-end inverter models tend to justify their price.

For model-specific operating guidance, maintenance intervals, and safety steps, follow the CMXGGAS030729 owner's manual.

Last updated: February 2026

The Craftsman CMXGGAS030729 generator runs up to about 19 hours at 50% load on a full tank under normal conditions. Actual runtime changes with total wattage, engine speed, and fuel quality; use the run-time and fueling guidance in the CMXGGAS030729 owner's manual for the best planning.

What affects runtime the most

Generator runtime is primarily fuel consumption; higher electrical demand burns more gasoline.

  • Load level (watts used): more watts equals shorter runtime
  • Motor starting surges: refrigerators, well pumps, and AC units increase fuel use
  • Eco/idle control setting (if equipped): steady, lighter loads run longer
  • Fuel condition: fresh gasoline runs cleaner and steadier than stale fuel
  • Maintenance: dirty air filter, spark plug wear, or carb issues reduce efficiency

Practical runtime planning by load

Use these planning ranges for portable gasoline generators like the CMXGGAS030729.

Load level Typical use example Runtime expectation
Light (about 25%) Lights, TV, small fan Often longer than the 50% load rating
Medium (about 50%) Fridge plus lights and small appliances Up to about 19 hours (published maximum)
Heavy (75% to 100%) Multiple large loads, frequent surges Shortest runtime; refuel more often

If your runtime seems shorter than expected

Work through these checks before assuming a major generator problem.

  • Reduce load; unplug high-surge items and add them back one at a time
  • Confirm breakers are not tripping; replace a weak breaker such as the generator circuit breaker, 20-amp 209872GS if it will not hold under normal load
  • Drain old fuel and refill with fresh gasoline
  • Check for fuel restriction or leaks; replace cracked lines with the fuel line kit 791745
  • If output is unstable, inspect the charging/excitation system; a failing generator voltage regulator 705692 can cause poor performance under load

Why it matters

Accurate runtime planning helps you schedule safe refueling, avoid overload shutdowns, and keep critical loads powered during outages.

Last updated: February 2026

Symptoms for top-mount refrigerators

Main causes: frozen or clogged defrost drain tube, cracked water system tubing…

Repair guides for top-mount refrigerators

How to replace the light switch in a top-freezer refrigerator

How to replace the light switch in a top-freezer refrigerator

The light switch turns the refrigerator light on and off and monitors door position. Replace the light switch if it does…

Repair time and Difficulty

 15 minutes or less
How to replace the water inlet valve in a top-freezer refrigerator

How to replace the water inlet valve in a top-freezer refrigerator

The water inlet valve controls water flow to the ice maker. Replace the water valve if it doesn't open or shut properly.…

Repair time and Difficulty

 15 minutes or less
How to replace the compressor run capacitor in a top-freezer refrigerator

How to replace the compressor run capacitor in a top-freezer refrigerator

The run capacitor sends electric current to the compressor motor to help the motor run efficiently. Replace the run capa…

Repair time and Difficulty

 15 minutes or less

Articles and videos for top-mount refrigerators

Can I fix my own fridge?

Can I fix my own fridge?

Find DIY repair tips to fix your refrigerator when it breaks down.…

How to replace Whirlpool refrigerator water filter EDR1RXD1 (EveryDrop Type 1)

How to replace Whirlpool refrigerator water filter EDR1RXD1 (EveryDrop Type 1)

Learn how to replace the Whirlpool EveryDrop 1 refrigerator water filter.…

How to replace open-tray-and-twist-out refrigerator water filters

How to replace open-tray-and-twist-out refrigerator water filters

Watch our video to see how to replace a refrigerator water filter located in a tray you open and then twist out the filt…

Parts & More

Bottom-Mount Refrigerator
Cooktop
Electric Range
Electronic Sewing Machine
Food Processor
Front-Engine Lawn Tractor
Gas Grill
Gas Snowblower
Lawn & Garden Engine
Lawn Sweeper
Parts
Refrigerator
Side-By-Side Refrigerator
Toaster Oven
Washer