Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Carrier 58CVA090---10016 furnace

Carrier 58CVA090---10016 furnace Parts

Here are the diagrams and repair parts for Carrier 58CVA090---10016 furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 58CVA090---10016 Furnace

Carrier Furnace 58CVA090---10016 FAQs

For your Carrier furnace model 58CVA090---10016, we recommend ordering replacement parts directly from the parts list for this model so you get the correct match for your unit’s series and serial. Use the installation guide to confirm the exact part group (ignition, blower, limit switches) before you buy.

What to do before you order

Having the right identifiers prevents wrong-part returns and repeat breakdowns.

  • Locate the unit rating plate and write down the model and serial number.
  • Identify the failing system: ignition, gas control, inducer, blower, or safety limits.
  • Compare your symptoms to the sequence of operation in the installation guide.
  • Match the part by description and identifier, not by “looks similar.”
  • If the furnace is shutting down on safety, correct airflow or venting issues before replacing parts.

Common Carrier furnace parts people replace first

These are frequent wear items on induced-combustion, variable-speed furnaces like this one.

Symptom Likely area Example part on this model page
No ignition, retries, then locks out Ignition system Furnace burner igniter LH33ZS004
Furnace starts then shuts off quickly High-limit safety opening Furnace temperature limit switch HH18HA495
Weak airflow or noisy blower Blower assembly Wheel blwr LA11XA048
No heat, control diagnostics indicate board issue Controls Control board HK42FZ035

Why it matters

Your 58CVA090---10016 uses multiple safety circuits (limit switch(es), door switch, pressure switch) and a specific control strategy. Buying the exact matched part helps keep ignition timing, blower performance, and overheat protection working as designed.

Last updated: February 2026

For a Carrier furnace like model 58CVA090---10016, blower motor replacement typically runs $300 to $700 total (parts plus labor). If your furnace uses a communicating or variable-speed style motor, the part cost alone can be much higher, so the final total can exceed that range.

What drives the total cost

  • Motor type: single-speed and multi-speed motors usually cost less than ECM or communicating motors
  • Labor time: access, venting layout, and wiring routing can add time
  • Related parts: a failing blower wheel, loose set screw, or damaged wiring can add parts and labor
  • Diagnosis time: confirming whether the motor, control module, or control board is at fault
  • Local labor rates: HVAC labor varies widely by region

Model-specific notes that affect pricing

Your installation guide for the 58CVA090---10016 includes blower assembly service steps and torque specs, which is a good indicator that access and reassembly details matter for labor time. Use the installation guide to confirm the correct disassembly sequence and wiring reconnection points before pricing the job.

Common “blower motor fault” causes to rule out first

The troubleshooting flow in the documentation points to several issues that can mimic a bad motor:

  • Rubbing blower wheel
  • Loose blower wheel
  • Wiring problems between the furnace control and blower motor
  • A failed blower control module attached to the motor (on some designs)

Quick cost snapshot

Scenario Typical parts cost Typical total installed
Standard PSC motor replacement $150 to $400 $300 to $700
ECM or communicating motor replacement $600 to $1,500+ $900 to $2,000+

Why it matters

A blower motor that is slow to start, noisy, or faulting can cause overheating trips (limit switch events), poor airflow, and repeated shutdowns. Getting the diagnosis right prevents replacing an expensive motor when the real issue is wiring, a loose wheel, or a control problem.

Last updated: February 2026

On the Carrier 58CVA090---10016 furnace, there typically is not a single universal “reset button” like you’d find on some appliances. Most resets are done by cycling power at the furnace (or using the thermostat to stop the heat call), and some safety switches are manual-reset depending on the fault. See the reset and safety-switch details in the installation guide.

What to check first (safe, quick steps)

  • Set the thermostat from HEAT to OFF (or lower the setpoint below room temperature).
  • Turn 115-volt power to the furnace OFF, then ON again (this is the most common “reset”).
  • Make sure the blower compartment door is fully installed; the door switch must be closed for the furnace to run.
  • Look through the sight glass for the control board LED status code (this points to the exact circuit that needs attention).
  • If the furnace is in a repeated fault, check the air filter and supply/return vents for airflow restrictions.

Where “reset” happens on this model

The installation information for this furnace describes reset actions in these common situations:

Situation What you’ll see What “reset” means
Control board lockout (after certain faults) Furnace stops heating; LED shows a status code Stop the heat call at the thermostat, then cycle 115-volt power OFF then ON
Limit circuit fault (limit, rollout, draft safeguard, blocked vent switch) Blower may run; heating stops Some switches auto-reset when cooled; manual-reset switches must be checked for continuity
Blower door switch open No operation Reinstall blower door so the switch closes

Why it matters

A furnace “reset” is really a safety step that clears a lockout so the control can try a normal ignition sequence again. If the underlying issue is still present (overheating, venting problem, pressure switch issue, blown 3-amp fuse), the furnace will fault again and protect the system.

When a part is commonly involved

If you’re seeing repeated overheating or limit-related faults, a failed limit switch is a common cause. For this model’s parts list, examples include the furnace temperature limit switch HH18HA495, furnace temperature limit switch HH18HA493, and furnace temperature limit switch HH18HA502.

Last updated: February 2026

On a Carrier 58CVA090---10016 furnace, the most expensive repair is typically a major core component replacement, most often the heat exchanger or a blower motor. These repairs cost the most because the parts are expensive and the labor is more involved; follow the safety steps in the installation guide before any service.

Most expensive furnace parts (typical)

These are the repairs that most often drive the highest total bill (parts plus labor):

  • Heat exchanger: highest-cost component on many furnaces
  • Blower motor: expensive part and can require significant disassembly
  • Control board: the furnace’s “brain”; diagnosis and replacement can be time-consuming
  • Draft inducer assembly (if equipped): can be a high-cost motorized component
  • Gas valve: less common, but can be costly when it fails

What we see on this model’s parts list

For the Carrier 58CVA090---10016, these examples from the parts list show how quickly costs can add up:

Component type Example part on this model Why it gets expensive
Heat exchanger Furnace heat exchanger (part number 326600-751) High part cost; major teardown to replace
Blower motor Blower motor 58MV660006 High part cost; setup and wiring must be correct
Control board Control board HK42FZ035 Diagnosis plus careful transfer of wiring/connectors

Why it matters

High-cost furnace repairs usually involve components tied to safe combustion and airflow. Your installation information also stresses turning off gas and electrical power and using lockout/tagout before service, because mistakes can create shock, fire, or carbon monoxide hazards.

Cost-control tips that prevent the biggest repairs

We recommend these practical steps to reduce the chance of expensive failures:

  • Replace or clean the air filter regularly; airflow problems can overheat the furnace and trip limit switches.
  • Keep the area around the furnace free of chemicals and vapors (some household products can contribute to corrosion).
  • If the furnace short-cycles or overheats, check for blocked returns, closed registers, or a dirty filter first.
  • If you see repeated limit trips, investigate airflow and blower performance before replacing parts.
  • After replacing any component, verify the correct operating sequence (as outlined in the service/troubleshooting flow in the guide).

Last updated: February 2026

Symptoms for upright freezers

Main causes: clogged or frozen defrost drain tube…

Repair guides for upright freezers

How to replace a freezer electronic control board

How to replace a freezer electronic control board

The electronic control board manages the compressor to control freezer temperature. Replace the control board using the…

Repair time and Difficulty

 45 minutes or less
How to replace a freezer thermistor

How to replace a freezer thermistor

When the thermistor can’t sense the freezer temperature, the freezer is colder or warmer than the set temperature. Follo…

Repair time and Difficulty

 45 minutes or less
How to replace a freezer door switch

How to replace a freezer door switch

When the door switch fails, the freezer can’t detect that the door is closed. Follow the steps in this repair guide to r…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Chest Freezer
Dryer
Electric Cooktop
Electric Range
Gas Grill
Gas Range
Lawn & Garden Engine
Plumbing
Range Hood
Refrigerator
Side-By-Side Refrigerator
Top-Mount Refrigerator
Upright Freezer
Washer