ICP FSM2X2400A1 fan coil Parts

Here are the diagrams and repair parts for ICP FSM2X2400A1 fan coil, as well as links to manuals and error code tables, if available.

ICP FSM2X2400A1 fan coil
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for FSM2X2400A1 Fan Coil

  • Central Air Conditioner Condenser Fan Motor Mount for ICP FSM2X2400A1 - Part 1170650

    Blower assy diagram

    Band Motor

    Part #1171733

    Replaced by #1170650

    Info Icon
    Manufacturer substitution
    This part replaces 1171733. Substitute parts can look different from the original.
    In Stock
    $46.42
    Minus Item
    Qty
    Plus Item
  • Wheel for ICP FSM2X2400A1 - Part 1171769

    Blower assy diagram

    Wheel

    Part #1171743

    Replaced by #1171769

    Info Icon
    Manufacturer substitution
    This part replaces 1171743. Substitute parts can look different from the original.
    In Stock
    $307.94
    Minus Item
    Qty
    Plus Item
  • Bolt for ICP FSM2X2400A1 - Part 1171713

    Blower assy diagram

    Bolt

    Part #1171713

    The manufacturer no longer makes this part, and there's no substitute part

  • Shield for ICP FSM2X2400A1 - Part 1172328

    Coil assy diagram

    Shield

    Part #1172328

    The manufacturer no longer makes this part, and there's no substitute part

  • Coil & Hdr Assy for ICP FSM2X2400A1 - Part 1172977

    Coil assy diagram

    Coil & Hdr Assy

    Part #1172977

    The manufacturer no longer makes this part, and there's no substitute part

  • Fuse for ICP FSM2X2400A1 - Part 1171735

    Blower assy diagram

    Fuse

    Part #1171735

    The manufacturer no longer makes this part, and there's no substitute part

  • Wrapper for ICP FSM2X2400A1 - Part 1172046

    Cabinet assy diagram

    Wrapper

    Part #1172046

    The manufacturer no longer makes this part, and there's no substitute part

  • Barrier Lv for ICP FSM2X2400A1 - Part 1171660

    Blower assy diagram

    Barrier Lv

    Part #1171660

    The manufacturer no longer makes this part, and there's no substitute part

  • Capacitor for ICP FSM2X2400A1 - Part 1171728

    Cabinet assy diagram

    Capacitor

    Part #1171728

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel Cutoff Blower for ICP FSM2X2400A1 - Part 1171570

    Blower assy diagram

    Panel Cutoff Blower

    Part #1171570

    The manufacturer no longer makes this part, and there's no substitute part

ICP Fan Coil FSM2X2400A1 FAQs

A heat pump indoor coil (often called the evaporator coil) is the heat exchanger inside your home that absorbs heat from indoor air during cooling and helps move heat into your home during heat pump heating. In an Icp fan coil like model FSM2X2400A1, it works with the blower to condition air and manage humidity.

What the indoor coil does in heating vs. cooling

  • Cooling mode: warm indoor air passes over the coil; heat and moisture are removed from the air.
  • Heat pump heating mode: the indoor coil becomes the “hot” coil; it releases heat into the air stream.
  • Works with the blower: airflow across the coil is required for proper heat transfer.
  • Supports comfort: proper coil performance helps with temperature control and indoor humidity.

Common signs the indoor coil needs attention

  • Weak airflow from vents (often tied to a dirty filter or airflow restriction)
  • Reduced cooling or heating capacity
  • Ice or frost on refrigerant lines or the coil area
  • Water around the unit from condensate drain issues
  • Higher run time or short cycling

What to check first on FSM2X2400A1

Your installation information emphasizes that the main consumer maintenance is air filter care and condensate drain operation. Start here before assuming the coil is bad:

Check What to do Why it matters
Air filter Inspect monthly; clean or replace as needed Low airflow can freeze the coil and reduce comfort
Condensate drain Make sure it drains freely A clogged drain can cause leaks and humidity problems
Blower operation Confirm the indoor blower runs in cooling/heating calls No airflow means the coil cannot exchange heat properly

If you need a replacement filter for this model, match it to the correct size and style listed for your unit; the parts list includes the furnace air filter 1171652.

Why it matters

The indoor coil is where heat transfer happens; when airflow is restricted (dirty filter, blower issue) or drainage is blocked, the system can lose capacity, ice up, or leak water. Keeping airflow and drainage correct protects the coil and improves efficiency.

Last updated: February 2026

No. On your Icp FSM2X2400A1 fan coil, the evaporator coil is one component inside the air handler (fan coil). The air handler is the indoor unit that moves air with a blower and houses the coil (and sometimes electric heat), while the coil is the part that absorbs heat for cooling.

What each part does

  • Air handler (fan coil): Indoor cabinet that contains the blower, controls, and the evaporator coil
  • Evaporator coil: Refrigerant coil that provides cooling by absorbing heat from indoor air
  • Electric heat kit (if equipped): Adds heat strips for auxiliary or emergency heat
  • Air filter: Protects the coil and blower from dust buildup (location varies by installation)

Quick comparison

Item What it is Main job Where you see it
Air handler (fan coil) Complete indoor unit Circulates air; supports cooling and sometimes heat Closet, attic, basement, or mechanical room
Evaporator coil Heat exchanger inside the air handler Provides cooling (and heat pump heating) Inside the air handler cabinet

Why it matters

Knowing the difference helps you troubleshoot correctly. For example, weak airflow points more toward the blower, filter, or controls, while poor cooling with normal airflow can point toward the evaporator coil, TXV, or refrigerant-side issues.

Model-specific notes for FSM2X2400A1

  • The installation instructions cover multiple FSM models and show that the evaporator coil is part of the fan coil assembly, with installation orientations (upflow, downflow conversion, horizontal) affecting access and drainage.
  • Condensate management is critical: the unit uses primary and secondary 3/4-inch NPT drain connections, and both drain lines should be installed with properly sized traps to prevent water issues.

If you are diagnosing a “fan not running” or intermittent blower operation, these model-listed parts are common starting points:

Before you service anything

  • Turn off power at the breaker and air handler disconnect.
  • Confirm the filter is clean and correctly installed.
  • If you are testing electrical components, use safe meter practices and follow the wiring diagram in the installation guide.

Last updated: February 2026

In most heat pump fan coil setups, the blower and evaporator coil are arranged in one of two airflow configurations: blow-through (blower before the coil) or draw-through (blower after the coil). Your Icp FSM2X2400A1 can be installed in orientations that place the coil assembly and blower in a defined cabinet layout.

The two common arrangements (what they mean)

  • Blow-through: the blower pushes air into the coil first, then air leaves the coil and goes to the ductwork.
  • Draw-through: the blower pulls air through the coil first, then pushes it into the ductwork.
  • Both designs are used in heat pump fan coils; the goal is steady airflow across the coil for good heating and cooling performance.

How this relates to the Icp FSM2X2400A1 cabinet

The installation instructions show the coil assembly and blower assembly as separate sections inside the fan coil cabinet, and they describe removing and reinstalling the coil assembly during horizontal conversions.

When you are converting the unit (for example, horizontal right), pay attention to:

  • Coil orientation and mounting (coil mounting screw and casing flange)
  • Condensate pan position (pan down)
  • Tubing and drain connection alignment
  • Reinstalling access panels to prevent air leaks and sweating

For the model-specific conversion steps and diagrams, use the installation guide.

Quick comparison

Configuration Blower location vs. coil Typical effect
Blow-through Blower before coil Coil sees positive pressure; cabinet sealing matters
Draw-through Blower after coil Coil sees negative pressure; drain and air bypass control matter

Why it matters

Blower-to-coil arrangement affects airflow, condensate management, and how sensitive the system is to air leaks. If airflow is wrong (dirty filter, duct restriction, wiring/control issue), the coil can underperform and comfort can drop.

If you are troubleshooting weak airflow or blower operation on this model, these parts are commonly involved:

Last updated: February 2026

Most common symptoms to help you fix your wall oven

Choose a symptom to see related wall oven repairs.

Main causes: bad oven door lock assembly, faulty electronic control board, wiring failure…

Main causes: faulty oven temperature sensor, control system problem, weak burner igniter, damaged oven element…

Main causes: lack of gas supply, broken igniter, tripped circuit breaker, broken oven element, tripped thermal fuse, con…

Main causes: lack of electrical power, bad electronic control board, faulty oven control thermostat…

Main causes: broken broil element, faulty broil burner igniter, control system failure…

Main causes: broken bake element, bad bake burner igniter, tripped thermal switch, control system failure…

Most common repair guides to help fix your wall oven

These step-by-step repair guides will help you safely fix what’s broken on your wall oven.

How to replace the thermal switch in a wall oven

How to replace the thermal switch in a wall oven

If the oven won't heat after resetting the thermal switch, replace the thermal switch.…

Repair time and Difficulty

 60 minutes or less
How to replace a wall oven thermal fuse

How to replace a wall oven thermal fuse

The thermal fuse trips to prevent the over from excessively overheating. The oven won't heat again until you replace the…

Repair time and Difficulty

 60 minutes or less
How to replace a wall oven door outer glass panel

How to replace a wall oven door outer glass panel

Learn how to replace a damaged outer window panel on your wall oven door with these step-by-step instructions. …

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your wall oven

Use the advice and tips in these articles and videos to get the most out of your wall oven.

How to remove grease from your oven

How to remove grease from your oven

Oven looking grimy? Discover how to clean a greasy oven using safe, effective methods like baking soda and more.…

How to read a wiring schematic video

How to read a wiring schematic video

Learn how to decipher symbols so you can buy the right part for your problem.…

How to correct an oven's temperature setting

How to correct an oven's temperature setting

If your oven consistently undercooks or overcooks, it might need recalibration. You can reset it yourself.…

Parts & More

Bottom-Mount Refrigerator
Canister Vacuum
Central Air Conditioner
Dishwasher
Dryer
Electric Range
Freestanding Freezer
Front-Engine Lawn Tractor
Gas Range
Gas Walk-Behind Mower
Lawn Sweeper
Parts
Range